Industrial Automation Parts. Prompt replies from real people.

WAGO 857-424 Isolation Amplifier

  • Warehouse stock, ready to ship
  • Fully genuine original parts
  • Free quotes within 24 hours
Get a Free Quote

Free quote · Reply within 24 hours

Last Updated: 11/24/2026

Q1Can you supply the WAGO 857-424?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the WAGO 857-424 cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
857-424
Material Number
—
Manufacturer
WAGO
Product ID
46632

Get a Free Quote

Request pricing and availability for 857-424.

More parts to source? Send your whole list in one enquiry

Key specifications

Rated voltage
300V
Protection type
IP20
Weight
42g
Ambient temperature (operation)
-40 … +70 °C (Individual arrangement; ?40 … +50 °C (block arrangement))
Input resistance (voltage input)
≤ 100 kΩ
Limit frequency
100 Hz?/ 1 KHz (configurable via DIP switch)
See all specifications

Product Highlights

  1. Dual configurable outputs: Two outputs, each configurable for voltage or current
  2. Isolation: Reinforced insulation with 3 kVAC test voltage for 1 min between input, analog output 1, analog output 2, and supply
  3. Input and output ranges: Input 0–5 V or 0–10 mA, output 2–10 V or 0–10 mA
  4. Accuracy: Transmission error ≤ 0.1 % of upper-range value, temperature coefficient ≤ 0.01 %/K
  5. Limit frequency: 100 Hz or 1 kHz, configurable via DIP switch
  6. Supply: 24 VDC SELV, -60/+30 % supply voltage range, current consumption < 27 mA default
  7. Connection: Push-in CAGE CLAMP® for solid 0.08–2.5 mm² (28–14 AWG) and fine-stranded 0.34–2.5 mm² (22–14 AWG), strip length 9–10 mm, shielded cable required
  8. Mounting and dimensions: DIN-35 rail mounting, 6 mm width, 94 mm height, 97.8 mm depth from upper DIN-rail edge
  9. Environmental: Operating temperature -40 to +70 °C individual arrangement or -40 to +50 °C block arrangement, storage -40 to +85 °C, relative humidity 5–95 % non-condensing, max operating altitude 2000 m
  10. Compliance: CE, EN 61010-1, EN 61000-6-2, EN 61000-6-3, EN 61326-1, EN 50121-3-2, RoHS compliant with exemption 6(c)
857-424

Product Information

Technical Specifications

Specifications for 857-424

ParameterValue
NoteUse shielded signal lines!Only use shielded signal lines for analog input and output signals.Only then can you ensure that the accuracy and interference immunity specified for the device can be achieved, even in the presence of interference acting on the signal cable.
Rated voltage300V
Measurement category per EN/UL 61010-2-030CAT II (input)
Protection typeIP20
Connection technologyPush-in CAGE CLAMP®
Solid conductor0.08 … 2.5 mm2 / 28 14 AWG
Fine-stranded conductor0.34 2.5 m㎡/ 22 14 AWG
Strip length9 10 mm / 0.35 0.39 inches
Cable typeShielded cable
Width6 mm / 0.236 inches
Height94 mm / 3.701 inches
Depth from upper-edge of DIN-rail97.8 mm / 3.85 inches
Mounting typeDIN-35 rail
Insulation material (main housing)Polyamide (PA66)
Flammability class per UL94V0
Fire load0.013MJ
Weight42g
Ambient temperature (operation)-40 … +70 °C (Individual arrangement; ?40 … +50 °C (block arrangement))
Ambient temperature (storage)-40 … 85 °C
Processing temperature-25 … +50 °C
Temperature range of connection cable≤ (Tambient+ 10 K)
Temperature range of connection cable (UL)75°C
Relative humidity5 95 % (non-condensing)
Operating altitude (max.)2000m
Conformity markingCE
EMC immunity to interferenceEN 61000-6-2; EN 61326-1; EN 50121-3-2
EMC emission of interferenceEN 61000-6-3; EN 61326-1; EN 50121-3-2
Standards/specificationsEN 61010-1
eCl@ss 10.027-21-01-20
eCl@ss 9.027-21-01-20
ETIM 9.0EC002653
ETIM 8.0EC002653
ECCNNO US CLASSIFICATION
PU (SPU)1 pcs
Packaging typebag
Country of originDE
GTIN4055143595476
Customs tariff number8543704500
CAS-No.1303-86-2
REACH Candidate List SubstanceDiboron trioxide
RoHS Compliance StatusCompliant,With Exemption
RoHS Exemption6(c)
SCIP notification number (Austria)20ff4e13-c0c9-4a74-b2cf-15a295ca8e56
ParameterValue
SCIP notification number (Belgium)3ba48a62-5e30-4a87-8bab-6ef1cc940417
SCIP notification number (Bulgaria)cc19b314-8dc8-4533-a619-bb5d1675c55d
SCIP notification number (Czech Republic)8c5e008b-53c5-482f-a3af-caacba45ef35
SCIP notification number (Denmark)975066ac-f476-426b-9150-59f316b9a26a
SCIP notification number (Finland)c19ee770-a5c7-4a8a-aa92-286b93a6362d
SCIP notification number (France)689b2ee7-0a3e-4f20-ad2c-38c625e92875
SCIP notification number (Germany)a9b66183-4d24-4f12-9fe9-cacbf2b0dc9a
SCIP notification number (Hungary)e1a182d3-453d-46fa-8dde-fca3c8f3c06b
SCIP notification number (Italy)68f65705-4017-4052-af20-4a8ab72a31ee
SCIP notification number (Netherlands)626ace7d-afda-43d4-8eea-41c485284027
SCIP notification number (Poland)5e15599a-8f67-4492-8627-517d77c7f6a2
SCIP notification number (Romania)8f949544-768f-44a9-a4e6-e617d0f0b22b
SCIP notification number (Sweden)444692de-f7c7-4ea3-bd3d-de5a8e18617e
Configuration optionsDIP switch
Input signal typeVoltage
Input signal (V)0 5 V
Input signal (A)0 10 mA
Input resistance (current input)≤ 50 Ω
Input resistance (voltage input)≤ 100 kΩ
Input current (max.)50 mA
Input voltage (max.)30 V
Output signal typeVoltage
Output signal (V)2 10 V
Output signal (A)0 10 mA
Load impedance (voltage output)≤ 2 kΩ (per channel)
Load impedance (current output)≤ 600 Ωper channel
Limit frequency100 Hz?/ 1 KHz (configurable via DIP switch)
Step response (typ.)5.2 ms (100 Hz);?650 µs (1 KHz)
Transmission error (typ.)≤ 0.1 % of upper-range value
Temperature coefficient≤ 0.01 %/K
Power supply type24 VDC (SELV)
Nominal supply voltage USDC 24 V
Supply voltage range-60 +30 %
Current consumption (default)< 27 mA
Current consumption (max.)< 250 mA (2 x Iout20 mA; Load impedance: 600 Ω; Us: 9.6 V)
Test voltage (input/analog output 1/analog output 2/supply)3 kVAC; 50 60 Hz; 1 min
Overvoltage categoryII
Pollution degree2
Insulation type (input/analog output1/analog output 2/supply)Reinforced insulation (safe isolation)

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.