Product Model
857-551
Material Number
—
Manufacturer
WAGO
Product ID
43344

Get a Free Quote

Request pricing and availability for 857-551.

More parts to source? Send your whole list in one enquiry

Key specifications

Rated voltage
300V
Protection type
IP20
Weight
38.2g
Ambient temperature (operation)
-40 … +70 °C (at nominal current)
Frequency range
16 200 Hz
Load impedance (voltage output)
≤ 2 kΩ
See all specifications

Product Highlights

  1. Input and Measurement: AC/DC current input 0 to 5 A (IN 1) with True RMS and arithmetic mean measurement, 16 to 200 Hz frequency range, 1 mA resolution, and 10 mA response threshold
  2. Measurement Range Setting: 0 to 6 A range settable only with WAGO Interface Configuration Software
  3. Outputs: 0 to 5 V voltage output with load impedance up to 2 kΩ and 0 to 10 mA current output with load impedance up to 600 Ω, plus digital output with 1 or 2 adjustable switching thresholds, 100 mA continuous current, and 0 to 60 s configurable rise/fall delay
  4. Supply and Isolation: 24 VDC SELV supply with ±30 % range and ≤ 50 mA current consumption, 3 kVAC test voltage, double insulation, overvoltage category II, and pollution degree 2
  5. Safety and Configuration: CAT II per EN 61010-2-030 with 300 VAC input and 300 V rated voltage, configuration via service interface only with voltage-free measurement input, DIP switch configuration options
  6. Connection and Mounting: Push-in CAGE CLAMP connection for solid 0.08 to 2.5 mm2 (28 to 14 AWG) and fine-stranded 0.34 to 2.5 mm2 (22 to 14 AWG) conductors with 9 to 10 mm strip length, DIN-35 rail mounting, 6 mm width, 94 mm height, 97.8 mm depth from upper DIN-rail edge, IP20 protection
  7. Environmental and Compliance: -40 to +70 °C operating temperature at nominal current, -40 to +85 °C storage temperature, 5 to 95 % relative humidity without condensation, maximum operating altitude 2000 m, CE conformity, EN 61010-1, EN 61000-6-2, EN 61000-6-3, EN 61326-1, UL94 V0 polyamide PA66 housing
857-551

Product Information

Technical Specifications

Specifications for 857-551

ParameterValue
NoteOnly the WAGO Interface Configuration Software can be used to set the measurement range of 0 to 6 A.
Rated voltage300V
Measurement category per EN 61010-2-030CAT II (input 300 VAC)
Note on insulation parametersDanger:Configuration via the service interface must only be performed with a voltage-free measurement input!
Protection typeIP20
Connection technologyPush-in CAGE CLAMP®
Solid conductor0.08 … 2.5 mm2 / 28 14 AWG
Fine-stranded conductor0.34 2.5 m㎡/ 22 14 AWG
Strip length9 10 mm / 0.35 0.39 inches
Width6 mm / 0.236 inches
Height94 mm / 3.701 inches
Depth from upper-edge of DIN-rail97.8 mm / 3.85 inches
Mounting typeDIN-35 rail
Insulation material (main housing)Polyamide (PA66)
Flammability class per UL94V0
Fire load0.013MJ
Weight38.2g
Ambient temperature (operation)-40 … +70 °C (at nominal current)
Ambient temperature (storage)-40 … 85 °C
Temperature range of connection cable≤ (Tambient+ 34 K)
Relative humidity5 95 % (no condensation permissible)
Operating altitude (max.)2000m
Conformity markingCE
EMC immunity to interferenceEN 61000-6-2, EN 61326-1
EMC emission of interferenceEN 61000-6-3; EN 61326-1
Standards/specificationsEN 61010-1
ETIM 9.0EC002475
ETIM 8.0EC002475
ECCNNO US CLASSIFICATION
PU (SPU)1 pcs
Packaging typebag
Country of originDE
GTIN4055143967129
Customs tariff number8543704500
ParameterValue
RoHS Compliance StatusCompliant,With Exemption
RoHS Exemption6(c)
Configuration optionsDIP switch
Input signal typeCurrent
Input signal (A)AC/DC 0 5 A (IN 1)
Frequency range16 200 Hz
Input resistance (current input)47 m? (IN 1);?10 m? (IN 2)
Input current (max.)15 A (IN 1; 5 s); 10 A (IN 3; 5 s)
Response threshold10 mA (IN 1); 2 mA (IN 3)
Resolution (current)1 mA (IN 1); 0.5 mA (IN 3)
Output signal typeCurrent
Output signal (V)0 5 V
Output signal (A)0 10 mA
Load impedance (voltage output)≤ 2 kΩ
Load impedance (current output)≤ 600 Ω
Switching voltage (DO) max.Supply voltage applied
Continuous current (DO) max.100 mA (no internal restriction)
Number of switching thresholds (DO)1 or 2 (adjustable)
Configurable rise/fall delay time (DO)0 … 60 s (via software)
Measurement methodTrue RMS measurement; Arithmetic mean value
Software filter (adjustable)Moving average value (filter level: 30)
Step response (typ.)60 ms (for software filter 3)
Step response (max.)250 ms
Transmission error (max.)≤ 0.5 % (of the full scale value)
Temperature coefficient1 A input: ≤ 0.01 %/K (typ.); ≤ 0.02 %/K (max.);5 A input: ≤ 0.02 %/K (typ.); ≤ 0.04 %/K (max.)
Nominal supply voltage USDC 24 V (SELV)
Supply voltage range±30 %
Current consumption at nominal supply voltage≤ 50 mA (+ IDO)
Test voltage (input/analog output/supply/service interface)3 kVAC; 50 Hz; 1 min
Overvoltage categoryII
Pollution degree2
Insulation type (input/analog output/supply/service interface)Double insulation (impedance and basic insulation)Requirement: The GND 1 input is dangerous when active and the measurement is conducted as a low-side measurement!