WAGO 857-815 Signal Conditioners

  • Warehouse stock, ready to ship
  • Fully genuine original parts
  • Free quotes within 24 hours
Get a Free Quote

Free quote · Reply within 24 hours

Last Updated: 11/24/2026

Q1Can you supply the WAGO 857-815?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the WAGO 857-815 cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
857-815
Material Number
—
Manufacturer
WAGO
Product ID
47348

Get a Free Quote

Request pricing and availability for 857-815.

More parts to source? Send your whole list in one enquiry

Key specifications

Rated voltage
300 V; 150 V (UL)
Protection type
IP20
Weight
38.9g
Ambient temperature (operation)
-25 … +70 °C
Supply voltage
DC 8 30 V (Power is derived from the output circuit.)
See all specifications

Product Highlights

  1. RTD Input: Pt100 sensors with 2-wire, 3-wire, or 4-wire switchable connection
  2. Measurement Range: -200 to 850 °C with a minimum span of 50 K
  3. Output: 4 to 20 mA current output, loop-powered via the output circuit with 8 to 30 VDC supply
  4. Accuracy: Transmission error ≤ 0.1 % at full measurement span, temperature coefficient ≤ 0.02 %/K, typical step response 1000 ms
  5. Isolation: Reinforced safe isolation between input and analog output, tested at 3 kVAC for 1 minute
  6. Connection: Push-in CAGE CLAMP® for solid conductors 0.08 to 2.5 mm² (28 to 14 AWG) and fine-stranded conductors 0.34 to 2.5 mm² (22 to 14 AWG), strip length 9 to 10 mm
  7. Mounting and Housing: DIN-35 rail mounting, 6 mm wide, 94 mm high, 97.8 mm deep from the upper edge of the DIN-rail, polyamide PA66 housing with UL94 V0 flammability class
  8. Environmental Ratings: IP20 protection, operating temperature -25 to +70 °C, storage temperature -40 to +85 °C, relative humidity 5 to 95 % without condensation, maximum operating altitude 2000 m
  9. Compliance: CE marked, EN 61010-1, EMC immunity per EN 61000-6-2, EN 61326-1, and EN 50121-3-2, EMC emission per EN 61000-6-3, EN 61326-1, and EN 50121-3-2, RoHS compliant
857-815

Product Information

Technical Specifications

Specifications for 857-815

ParameterValue
Safety informationThe signal conditioner must only be configured with the DIP switch in the de-energized state.
NoteUse shielded signal lines!Only use shielded signal lines for analog input and output signals.Only then can you ensure that the accuracy and interference immunity specified for the device can be achieved, even in the presence of interference acting on the signal cable.
Rated voltage300 V; 150 V (UL)
Measurement category per EN/UL 61010-2-030CAT II (input)
Protection typeIP20
Connection technologyPush-in CAGE CLAMP®
Solid conductor0.08 … 2.5 mm2 / 28 14 AWG
Fine-stranded conductor0.34 2.5 m㎡/ 22 14 AWG
Strip length9 10 mm / 0.35 0.39 inches
Width6 mm / 0.236 inches
Height94 mm / 3.701 inches
Depth from upper-edge of DIN-rail97.8 mm / 3.85 inches
Mounting typeDIN-35 rail
Insulation material (main housing)Polyamide (PA66)
Flammability class per UL94V0
Fire load0.013MJ
Weight38.9g
Ambient temperature (operation)-25 … +70 °C
Ambient temperature (storage)-40 … 85 °C
Temperature range of connection cable≤ (Tambient+ 10 K)
Temperature range of connection cable (UL)75°C
Relative humidity5 95 % (no condensation permissible)
Operating altitude (max.)2000m
Conformity markingCE
EMC immunity to interferenceEN 61000-6-2; EN 61326-1; EN 50121-3-2
EMC emission of interferenceEN 61000-6-3; EN 61326-1; EN 50121-3-2
Standards/specificationsEN 61010-1
eCl@ss 10.027-21-01-29
eCl@ss 9.027-21-01-29
ETIM 9.0EC002919
ETIM 8.0EC002919
ECCNNO US CLASSIFICATION
PU (SPU)1 pcs
Packaging typebag
Country of originDE
GTIN4055143475648
Customs tariff number85437090300
CAS-No.1303-86-2
REACH Candidate List Substance2,2',6,6'-tetrabromo-4,4'-isopropylidenediphenol
RoHS Compliance StatusCompliant,No Exemption
RoHS Exemption6(c)
SCIP notification number (Austria)830a7e26-28ea-4705-ab6e-226f9c633520
ParameterValue
SCIP notification number (Belgium)63788937-7a1f-4563-936a-f01960202294
SCIP notification number (Bulgaria)7573483d-d923-4363-9064-ce0784b75504
SCIP notification number (Czech Republic)17fdd5aa-0c9d-4035-8fac-fb4e34ddac7f
SCIP notification number (Denmark)f6a88738-2c30-4e26-8f7e-78d92a8961e5
SCIP notification number (Finland)b4ce184e-8252-4b06-b805-6aa2c771805f
SCIP notification number (France)7d65f4e8-4b0d-4e4d-922c-5b4b37ec9f15
SCIP notification number (Germany)7eda7375-97a9-4708-8499-ee382843832f
SCIP notification number (Hungary)eef5d1bb-60c8-4a7b-815f-42f57a0b5106
SCIP notification number (Italy)9d811551-d172-4095-9c09-acc10881822b
SCIP notification number (Netherlands)5b4bce60-08c5-43bc-b361-c0de92c2e4da
SCIP notification number (Poland)05d900c2-b348-49b3-9862-d1595b7b0a8f
SCIP notification number (Romania)5914960a-62a8-45a9-95fc-a9ee80aab951
SCIP notification number (Sweden)d4592a7f-9ffa-4c4d-9de5-be795739849b
Configuration optionsDIP switch
Input signal typeResistance
Sensor types (RTD)Pt100
Sensor connection2-wire; 3-wire; 4-wire (switchable)
Sensor power supply (RTD) max.≤ 0.5 mA
Temperature measurement range (RTD)-200 850 °C
Measurement span (RTD) min.50K
Input range (resistor)0 1 kΩ;?0 4.5 kΩ
Output signal typeCurrent
Output signal (A)4 20 mA
Load impedance (current output)See derating graphic
Step response (typ.)1000 ms
Transmission error (typ.)≤ 0.1 % at full measurement span
Transmission error for the set measurement range≤ ((40 K/set measurement range [K]) + 0.1) %
Transmission error (under interference)≤ 5 %
Temperature coefficient≤ 0.02 %/K
Power supply typeLoop-powered (via output)
Supply voltageDC 8 30 V (Power is derived from the output circuit.)
Power loss (max.) Pl (max.)0.7 W
Test voltage (input/analog output)3 kVAC; 50 60 Hz; 1 min
Overvoltage categoryII
Pollution degree2
Insulation type (input/analog output)Reinforced insulation (safe isolation)
Insulation type (input/analog output/supply)Reinforced insulation (safe isolation)