- 857-416
WAGO 857-416 signal conditioner, a pre-configured isolation amplifier for converting a 4–20 mA current input to a 0–10 V voltage output. It operates from a 24 VDC (SELV) supply with a ±30 % supply voltage range and consumes ≤ 25 mA. Input resistance is ≤ 50 Ω; voltage output load impedance is ≤ 2 kΩ. Typical transmission error is ≤ 0.1 % of upper-range value, temperature coefficient ≤ 0.01 %/K, limit frequency 100 Hz, and typical step response 3.5 ms. The 6 mm wide module mounts on a DIN-35 rail and uses Push-in CAGE CLAMP® connections for solid conductors 0.08–2.5 mm² (28–14 AWG) and fine-stranded conductors 0.34–2.5 mm² (22–14 AWG), with 9–10 mm strip length. Rated voltage 300 V; test voltage AC 3 kV, 50 Hz, 1 min. Operating ambient temperature −25 to +70 °C; IP20; CE marking.
- 857-420
WAGO 857-420 signal conditioner with DIP-switch configuration. Input is current, 0–20 mA, with input resistance ≤ 50 Ω and maximum input current 50 mA. Sensor supply is Uv = 18 V; 30 mA. Outputs are current 0–20 mA and voltage 0–5 V, with load impedance ≤ 600 Ω for current output and ≤ 2 kΩ for voltage output. Offset is ≤ 20 µA, residual ripple ≤ 10 mV (rms), limit frequency 100 Hz, typical step response 3.5 ms, typical transmission error ≤ 0.1 % of upper-range value, and temperature coefficient ≤ 0.01 %/K. Supply is DC 24 V nominal with ±30 % range and current consumption ≤ 45 mA. Test voltage input/output/supply is AC 2.5 kV; 50 Hz; 1 min. DIN-35 rail mounting, 6 mm wide, IP20, push-in CAGE CLAMP connection.
- 857-423
WAGO 857-423 signal conditioner with voltage and current inputs and two configurable current outputs. Inputs accept 0–5 V or 0–20 mA; output is 0–20 mA per channel with load impedance up to 300 Ω per channel. Configuration is via DIP switch, including a limit frequency of 100 Hz or 1 kHz; typical step response is 3.5 ms at 100 Hz and 300 µs at 1 kHz. Typical transmission error is ≤ 0.1 % of upper-range value, maximum ≤ 0.2 %. Supply is DC 24 V with ±30 % range and current consumption ≤ 35 mA. Rated voltage 300 V, overvoltage category II, pollution degree 2. Push-in CAGE CLAMP® connection, 6 mm wide, DIN-35 rail mounting, IP20, operating temperature -25 to +70 °C.
- 857-424
WAGO 857-424 signal conditioner/isolation amplifier for analog signals. Inputs: 0–5 V (voltage) and 0–10 mA (current); outputs: 2–10 V and 0–10 mA. Input resistance is ≤100 kΩ for voltage input and ≤50 Ω for current input; maximum input voltage 30 V, maximum input current 50 mA. Limit frequency is configurable via DIP switch at 100 Hz or 1 kHz, with typical step response 5.2 ms at 100 Hz and 650 µs at 1 kHz. Typical transmission error is ≤0.1 % of upper-range value; temperature coefficient ≤0.01 %/K. Supply is 24 VDC (SELV), current consumption <27 mA default. Test voltage input/analog output 1/analog output 2/supply: 3 kVAC, 50–60 Hz, 1 min. Reinforced insulation (safe isolation). 6 mm wide, DIN-35 rail mounting. Use shielded signal lines.
- 857-450
WAGO 857-450 signal conditioner, loop-powered via the output circuit. Input accepts ±1 V or ±5 mA; output is 4–20 mA with a maximum load impedance of 600 Ω. Supply voltage is DC 8–30 V, derived from the output circuit. Configuration is via DIP switch, with a limit frequency of 100 Hz or 30 Hz selectable by DIP switch. Typical step response is 3.5 ms; transmission error is ≤0.1 % of upper-range value; temperature coefficient is ≤0.01 %/K. Test voltage input/output/supply is AC 2.5 kV at 50 Hz for 1 min. Connections use Push-in CAGE CLAMP® for solid conductors 0.08–2.5 mm² (28–14 AWG) and fine-stranded conductors 0.34–2.5 mm² (22–14 AWG), strip length 9–10 mm. DIN-35 rail mounting, 6 mm wide, IP20, operating temperature -25 to +70 °C.
- 857-451
WAGO 857-451 passive signal conditioner for 1-channel current isolation. Input and output are both 0–20 mA; maximum input current 40 mA and maximum input voltage 20 V. The response threshold is 200 μA, limit frequency 100 Hz, and typical step response 3.5 ms. Transmission error is ≤ 0.1 % of upper-range value, load error ≤ 0.05 % per 100 Ω load, and temperature coefficient ≤ 0.01 %/K. The current output permits load impedance ≤ 600 Ω, with possible temperature range restrictions; voltage drop is ≤ 2.5 V at 20 mA. Power is supplied passively via the input. Reinforced insulation provides safe isolation between input and analog output; test voltage is AC 3 kV, 50 Hz, 1 min. Rated voltage 300 V; measurement category CAT II (input); overvoltage category II; pollution degree 2; protection type IP20. Use shielded signal lines. Outputs must not be left open.
- 857-452
WAGO 857-452 passive signal isolator for current signals, 2-channel, powered via the input. Input and output are 0–20 mA; maximum input current 40 mA, maximum input voltage 20 V, response threshold 200 µA. Load impedance for the current output is ≤ 600 Ω, with possible temperature range restrictions. Voltage drop is ≤ 2.5 V at 20 mA (output). Limit frequency is 100 Hz and typical step response is 3.5 ms. Typical transmission error is ≤ 0.1 % of upper-range value; load error ≤ 0.05 % per 100 Ω load; temperature coefficient ≤ 0.01 %/K. Rated voltage 300 V; measurement category CAT II (input) per EN/UL 61010-2-030; overvoltage category II; pollution degree 2; IP20. Connection is Push-in CAGE CLAMP®. Outputs must not be left open.
- 857-500
WAGO 857-500 signal conditioner converts frequency signals to current or voltage outputs. It accepts frequency generators, NAMUR sensors per DIN EN 50227, and NPN/PNP transistor outputs without pull-up or pull-down resistors. Frequency ranges are 0.1 Hz to 120 kHz, 0.1 Hz to 1 kHz, and 0.1 Hz to 20 kHz respectively. Configuration is via DIP switch. Outputs are 0 to 5 V and 0 to 10 mA. Supply is DC 24 V with ±30 % tolerance and current consumption ≤ 40 mA. Transmission error is ≤ 0.1 % of upper-range value; temperature coefficient ≤ 0.01 %/K. The 6 mm wide module mounts on DIN-35 rail, uses Push-in CAGE CLAMP® connections, and operates from -25 to +70 °C.