- 859-314
WAGO 859-314 relay module with one changeover contact (SPDT) and AgNi + Au contact material. Nominal input voltage is DC 24 V with an input voltage range of -15 to +20 percent and nominal input current of 10 mA at UN. The limiting continuous current is 5 A; maximum switching voltage is AC 250 V, and maximum resistive switching power is AC 1250 VA, with DC per the load limit curve. A red LED provides status indication. Gold-layer contacts require switching voltages not exceeding 30 V and currents not exceeding 50 mA. Connection uses CAGE CLAMP for solid and fine-stranded conductors from 0.08 to 2.5 mm2 (28 to 14 AWG), strip length 5 to 6 mm. Width is 6 mm, mounting is DIN-35 rail, and protection type is IP20 in connected state or with the 859-525 end plate. Standards/specifications: EN 61010-2-201.
- 859-354
The WAGO 859-354 is a DIN-35 rail-mounted relay module in the Interface Electronic product group. It has a nominal input voltage of AC/DC 24 V with an input voltage range of -15 to +10 percent and a nominal input current of 8 mA at UN. It provides one changeover contact with AgSnO2 contact material, a limiting continuous current of 5 A, and a maximum switching voltage of AC 250 V. Connection is via CAGE CLAMP, accepting 0.08 to 2.5 mm2 (28 to 14 AWG) solid and fine-stranded conductors, with a 5 to 6 mm strip length. The module is 6 mm wide, 91 mm high, and 56 mm deep from the upper edge of the DIN rail. It is gray, IP20 rated in connected state or when using the 859-525 end plate, and operates from -40 to +50 degrees C at UN. Standards/specifications: EN 61010-2-201.
- 859-355
WAGO 859-355 switching relay terminal block, 6 mm wide, mounts on DIN-35 rail. Nominal input voltage is AC/DC 48 V with an input voltage range of -15 to +10 % and nominal input current of 6 mA at UN. It provides one changeover contact with AgSnO2 contact material, a limiting continuous current of 5 A, and a maximum switching voltage of AC 250 V. Switching power is AC 1250 VA resistive; DC per load limit curve. Connection uses CAGE CLAMP® technology for solid and fine-stranded conductors from 0.08 to 2.5 mm2 (28 to 14 AWG), strip length 5 to 6 mm. Protection type is IP20 in connected state or when using the 859-525 end plate. Operating ambient temperature is -40 to +50 °C at UN. Standards/specifications: EN 61010-2-201.
- 859-357
WAGO 859-357 relay module with AC/DC 115 V nominal input voltage, -15 to +10 % input voltage range, and 4 mA nominal input current at UN. It provides one changeover contact with AgSnO2 contact material, 5 A limiting continuous current, maximum AC 250 V switching voltage, and maximum AC 1250 VA resistive switching power. Typical pull-in time is 15 ms, drop-out time 25 ms, and bounce time 3.5 ms. The module is 6 mm wide, 91 mm high, and mounts on DIN-35 rail via CAGE CLAMP connection for 0.08 to 2.5 mm2 conductors. It operates from -40 to +50 °C at UN and carries IP20 protection when connected or with the 859-525 end plate. A red LED indicates status. Inductive loads require an effective protection circuit.
- 859-367
WAGO 859-367 relay module with AC 115 V nominal input voltage, ±10 % input voltage range, and 5 mA nominal input current at UN. It has one changeover contact made of AgSnO2, a 5 A limiting continuous current, and a maximum switching voltage of AC 250 V. Maximum resistive switching power is AC 1250 VA; DC ratings follow the load limit curve. Typical pull-in time is 15 ms, drop-out time 25 ms, and bounce time 3.5 ms. The module is 6 mm wide and mounts on a DIN-35 rail. Connection uses CAGE CLAMP® technology for solid and fine-stranded conductors from 0.08 to 2.5 mm2 (28 to 14 AWG). Protection type is IP20 in connected state or when using the 859-525 end plate. Operating ambient temperature at UN is -40 to +50 °C. Standards/specifications: EN 61010-2-201.
- 859-390
WAGO 859-390 relay module, gray, for DIN-35 rail mounting. Nominal input voltage is DC 24 V with an input voltage range of -30 to +25 percent and nominal input current of 12 mA at UN. It has one changeover contact with AgSnO2 contact material, a limiting continuous current of 5 A, and a maximum switching voltage of AC 250 V. Switching power is AC 1250 VA resistive, with DC per the load limit curve. Status indication is a red LED. Dimensions are 6 mm wide, 91 mm high, and 56 mm deep from the upper DIN-rail edge. Connection uses CAGE CLAMP for 0.08 to 2.5 mm2 (28 to 14 AWG) conductors, strip length 5 to 6 mm. Ambient operating temperature is -40 to +70 degrees C. Standards/specifications: EN 61010-2-201.
- 859-393
WAGO 859-393 relay module, 6 mm wide, with one changeover contact and a nominal input voltage of DC 72 V. Input voltage range is -30 to +25 percent; nominal input current at UN is 5 mA. The contact material is AgSnO2, limiting continuous current is 3 A, and maximum switching voltage is AC 250 V. Switching power (resistive) is AC 750 VA maximum, with DC per the load limit curve. Status is indicated by a red LED. Connection uses CAGE CLAMP; solid and fine-stranded conductors accept 0.08 to 2.5 mm2 (28 to 14 AWG), strip length 5 to 6 mm. Mounting is on DIN-35 rail. Ambient operating temperature at UN is -40 to +70 degrees C. Standards/specifications: EN 61010-2-201. Inductive loads must be dampened with an effective protection circuit.
- 859-397
WAGO 859-397 relay module with DC 48 V nominal input, ±40 % input voltage range, and 8 mA nominal input current at UN. It has one changeover contact with AgSnO2 contact material, 5 A limiting continuous current, and maximum switching voltage of AC 250 V. Switching power is AC 1250 VA resistive, DC per load limit curve. Typical pull-in, drop-out, and bounce times are 15 ms, 25 ms, and 3.5 ms. CAGE CLAMP connection accepts 0.08 to 2.5 mm2 (28 to 14 AWG) conductors, strip length 5 to 6 mm. Dimensions: 6 mm wide, 91 mm high, 56 mm depth from DIN-35 rail. Operating ambient temperature -40 to +70 °C. Protection type IP20. Standards: EN 61010-2-201.