- 859-397
WAGO 859-397 relay module with DC 48 V nominal input, ±40 % input voltage range, and 8 mA nominal input current at UN. It has one changeover contact with AgSnO2 contact material, 5 A limiting continuous current, and maximum switching voltage of AC 250 V. Switching power is AC 1250 VA resistive, DC per load limit curve. Typical pull-in, drop-out, and bounce times are 15 ms, 25 ms, and 3.5 ms. CAGE CLAMP connection accepts 0.08 to 2.5 mm2 (28 to 14 AWG) conductors, strip length 5 to 6 mm. Dimensions: 6 mm wide, 91 mm high, 56 mm depth from DIN-35 rail. Operating ambient temperature -40 to +70 °C. Protection type IP20. Standards: EN 61010-2-201.
- 859-702
WAGO 859-702 optocoupler module for signal isolation in 3-wire connection. Nominal input voltage is DC 5 V, with low-level input range DC 0 to 1.5 V and high-level input range DC 4 to 6.25 V; nominal input current at UN is 11.7 mA. Nominal output voltage is DC 24 V, output voltage range DC 15 to 30 V, limiting continuous current 1 A, voltage drop ≤ 1.3 VDC, and switching frequency ≤ 15 kHz. Dielectric strength between control and load circuit is 2.5 kVrms (AC, 1 min), basic insulation. Rated voltage 300 V, overvoltage category II, pollution degree 2. Connection is CAGE CLAMP; solid conductor 0.2 to 2.5 mm2, fine-stranded conductor 0.14 to 2.5 mm2, strip length 5 to 6 mm. DIN-35 rail mounting, gray polyamide PA66 housing, IP20, width 6 mm, weight 18.3 g. Operating ambient temperature -40 to +70 °C. Standards/specifications: EN 61010-2-201.
- 859-706
WAGO 859-706 is a DIN-35 rail-mount optocoupler for signal isolation in networks not supplied directly by the low-voltage power supply network. It has a nominal input voltage of DC 24 V, a high-level input range of DC 16 to 30 V, and a low-level range of DC 0 to 10 V, drawing 12.3 mA at UN. Nominal output voltage is DC 5 V with an output range of DC 4 to 6.25 V; limiting continuous current is 0.5 A. Switching frequency is up to 20 kHz, with turn-on time up to 3 microseconds and turn-off time up to 13 microseconds. Dielectric strength between control and load circuit is 2.5 kVrms AC for 1 minute. Connection is 3-wire CAGE CLAMP, 6 mm wide, IP20 when connected or with 859-525 end plate, operating from -40 to +70 C.
- 859-708
WAGO 859-708 optocoupler module for signal isolation in 3-wire connection. Nominal input voltage is DC 24 V, with an input voltage range of DC 22 to 30 V, low level DC 0 to 5 V, and high level DC 19 to 30 V. Nominal input current at UN is 9 mA. Nominal output voltage is DC 24 V, output voltage range DC 14 to 30 V, limiting continuous current 1 A, voltage drop ≤ 1.2 VDC, and leakage current at rated voltage ≤ 5 µA. Switching frequency is ≤ 15 kHz, with turn-on time ≤ 7 µs and turn-off time ≤ 14 µs. Dielectric strength between control and load circuit is 2.5 kVrms AC for 1 min, basic insulation. Rated voltage 300 V, overvoltage category II, pollution degree 2. Connection is CAGE CLAMP, 6 mm wide, DIN-35 rail mounting, IP20, per EN 61010-2-201.
- 859-712
WAGO 859-712 optocoupler module for low-side switching, 3-wire connection. Nominal input voltage AC 230 V; input ranges AC 0–90 V (low level) and AC 175–270 V (high level); nominal input current 1 mA at UN. Nominal output voltage DC 24 V, output voltage range DC 20–30 V, limiting continuous current 0.5 A, voltage drop ≤ 1.2 VDC, leakage current ≤ 10 µA at rated voltage, turn-on and turn-off time ≤ 30 ms each. Rated voltage 300 V, overvoltage category II, pollution degree 2, dielectric strength 3 kVrms (AC, 1 min) between control and load circuit. CAGE CLAMP connection accepts 0.08–2.5 mm2 (28–14 AWG); strip length 5–6 mm. Dimensions 6 mm wide, 91 mm high, 56 mm deep from DIN-rail upper edge; DIN-35 rail mounting. Ambient operating temperature -25 to +55 °C. Standards: EN 61010-2-201.
- 859-720
WAGO 859-720 optocoupler module for signal processing networks not supplied directly by the low-voltage power supply network. Nominal input voltage is DC 24 V, with input ranges of DC 0–3 V (low) and DC 16–30 V (high), and nominal input current of 4 mA at UN. Output is nominal DC 24 V over a DC 10–30 V range, with 3 A limiting continuous current and 20 A peak output current. It uses 3-wire connection and CAGE CLAMP® technology for 0.08–2.5 mm2 (28–14 AWG) conductors. Dielectric strength is 2.5 kVrms (AC, 1 min) with basic insulation between control and load circuits. DIN-35 rail mounting, 6 mm wide, IP20 in connected state or with 859-525 end plate, per EN 61010-2-201.
- 859-730
WAGO 859-730 optocoupler module for signal processing networks not supplied directly by the low-voltage power supply network. Nominal input voltage is DC 24 V, with input ranges of DC 0 to 7.5 V (low level) and DC 12.5 to 30 V (high level), and nominal input current 15 mA at UN. Output is DC 24 V nominal, DC 3 to 30 V range, 4.8 A limiting continuous current, 25 A peak, voltage drop ≤ 0.4 VDC, and leakage current ≤ 45 µA at rated voltage. Switching: turn-on ≤ 20 µs, turn-off ≤ 1 ms, switching frequency ≤ 2.3 kHz. Dielectric strength control/load circuit is 2.5 kVrms AC, 1 min, basic insulation. CAGE CLAMP connection, 6 mm wide, DIN-35 rail mounting, IP20, per EN 61010-2-201.
- 859-734
WAGO 859-734 optocoupler module for safe isolation and signal processing in mains circuits not supplied directly by the low-voltage power supply network. Nominal input voltage is DC 24 V (range DC 16–30 V); nominal input current at UN is 7 mA. Output is AC 230 V nominal, with an output voltage range of AC 12–260 V at 50–60 Hz. Limiting continuous current is 1 A, minimum switching current 10 mA, and peak output current 30 A. Dielectric strength between control and load circuit is 3.5 kVrms for 1 min, with reinforced insulation (safe isolation). Connection is 2-wire CAGE CLAMP®; width 6 mm, DIN-35 rail mounting, IP20 in connected state or with 859-525 end plate. Standards/specifications: EN 61010-2-201.