Industrial Automation Parts. Prompt replies from real people.

WAGO 859-354 Relay Module

  • Warehouse stock, ready to ship
  • Fully genuine original parts
  • Free quotes within 24 hours
Get a Free Quote

Free quote · Reply within 24 hours

Last Updated: 11/24/2026

Q1Can you supply the WAGO 859-354?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the WAGO 859-354 cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
859-354
Material Number
—
Manufacturer
WAGO
Product ID
43321

Get a Free Quote

Request pricing and availability for 859-354.

More parts to source? Send your whole list in one enquiry

Key specifications

Rated voltage
300V
Rated surge voltage
4kV
Protection type
IP20; in connected state or when using 859-525 end plate
Weight
22.4g
Ambient temperature (operation at UN)
-40 … +50 °C
Switching frequency with/without load (max.)
6 min-1/ 180 min-1
See all specifications

Product Highlights

  1. Input: 24 V AC/DC nominal, -15 to +10 % input voltage range, 8 mA nominal input current
  2. Contacts: 1 changeover contact, AgSnO2 contact material, 5 A limiting continuous current, 250 V AC maximum switching voltage
  3. Switching capacity: 1250 VA resistive AC, AC-15 3 A at 250 V, DC-13 2 A at 24 V, recommended minimum load 10 V at 10 mA or 24 V at 1 mA
  4. Timing: 15 ms typical pull-in, 25 ms typical drop-out, 3.5 ms typical bounce
  5. Isolation: 4 kVrms control/load dielectric strength, 1 kVrms open-contact dielectric strength, reinforced insulation for safe isolation
  6. Connection: CAGE CLAMP, 0.08 to 2.5 mm2 solid and fine-stranded, 0.08 to 1.5 mm2 fine-stranded with insulated ferrule, 5 to 6 mm strip length
  7. Mounting: DIN-35 rail, 6 mm width, 91 mm height, 56 mm depth from upper DIN-rail edge, horizontal or vertical mounting position
  8. Housing: gray PA66, IP20 in connected state or with 859-525 end plate, UL94 V0 flammability class
  9. Operating conditions: -40 to +50 °C ambient at UN, -40 to +70 °C storage, 5 to 95 % relative humidity without condensation, up to 2000 m altitude
  10. Standards and compliance: EN 61010-2-201, RoHS compliant with exemption 7(a), REACH candidate list substance 2,2',6,6'-tetrabromo-4,4'-isopropylidenediphenol
  11. Status indicator: red LED
859-354

Product Information

Technical Specifications

Specifications for 859-354

ParameterValue
NoteTo protect the relay coils and contacts, inductive loads must be dampened with an effective protection circuit.
Rated voltage300V
Rated surge voltage4kV
Overvoltage categoryIII
Pollution degree2
Dielectric strength (control/load circuit) (AC, 1 min)4 kVrms
Dielectric strength (open contact) (AC, 1 min)1 kVrms
Insulation type (control/load circuit)Reinforced insulation (safe isolation)
Insulation type (adjacent devices)Reinforced insulation (safe isolation)
Protection typeIP20; in connected state or when using 859-525 end plate
Connection technologyCAGE CLAMP®
Solid conductor0.08 … 2.5 mm2 / 28 14 AWG
Fine-stranded conductor0.08 … 2.5 mm2 / 28 14 AWG
Fine-stranded conductor; with insulated ferrule0.08 1.5 m㎡/ 28 16 AWG
Strip length5 6 mm / 0.2 0.24 inches
Width6 mm / 0.236 inches
Height91 mm / 3.583 inches
Depth from upper-edge of DIN-rail56 mm / 2.205 inches
Mounting typeDIN-35 rail
Mounting positionHorizontal (standing/lying); vertical
Note (material data)Information on material specifications can be found here
Colorgray
Insulation material (main housing)Polyamide (PA66)
Material groupI
Flammability class per UL94V0
Fire load0.538MJ
Weight22.4g
Ambient temperature (operation at UN)-40 … +50 °C
Ambient temperature (storage)-40 … +70 °C
Processing temperature-25 … +50 °C
Temperature range of connection cable≤ (Tambient+ 20 K)
Relative humidity5 95 % (no condensation permissible)
Operating altitude (max.)2000m
Standards/specificationsEN 61010-2-201
Product Group6 (INTERFACE ELECTRONIC)
eCl@ss 10.027-37-16-01
eCl@ss 9.027-37-16-01
ETIM 9.0EC001437
ETIM 8.0EC001437
ECCNNO US CLASSIFICATION
PU (SPU)10 pcs
Packaging typebox
Country of originCN
ParameterValue
GTIN4055143603980
Customs tariff number8536490080
CAS-No.7439-92-1
REACH Candidate List Substance2,2',6,6'-tetrabromo-4,4'-isopropylidenediphenol
RoHS Compliance StatusCompliant,With Exemption
RoHS Exemption7(a)
SCIP notification number (Austria)8e44aa1e-7fd5-446b-b85e-430c61810447
SCIP notification number (Belgium)acd93eeb-9031-4a59-b05f-9fe3f4afc9f4
SCIP notification number (Bulgaria)86cf0685-3ced-4c22-9dd8-bfa604ace64f
SCIP notification number (Czech Republic)53198a62-5dbe-40ff-9c84-672c561b0ac5
SCIP notification number (Denmark)8868e198-e2a5-4370-88c8-72f64ff76235
SCIP notification number (Finland)b799c197-5727-472e-b608-53a8e82ee6f4
SCIP notification number (France)4732161b-b89b-4aeb-b227-7b02aeaed553
SCIP notification number (Germany)be5fb66c-d7aa-41a0-9781-0e3a4ca0a00e
SCIP notification number (Hungary)a8bd318b-f775-4a9f-99eb-a57a02f1c4f4
SCIP notification number (Italy)8ac6f5e8-7f68-43f6-8cad-e7a33aa0adc3
SCIP notification number (Netherlands)0b3a4d57-bfe6-4f91-b7cf-a52823f57593
SCIP notification number (Poland)659ce3fb-4c88-47ca-9494-1e9919f1f0dd
SCIP notification number (Romania)0602c7ed-dd97-48da-935e-14b447438f18
SCIP notification number (Sweden)bc0b7b6e-06db-4d2f-9f21-d97fd0b8282b
Nominal input voltage UNAC/DC 24 V
Input voltage range-15 +10 %
Nominal input current at UN8 mA
Number of changeover contacts1
Contact material (relay)AgSnO2
Limiting continuous current5 A
Inrush current (resistive) max.(AC) 20 A?/ 0.02?s
Switching Voltage, Max.AC 250 V
Switching power (resistive) max.AC 1250 VA; DC (see load limit curve)
Switching capacityAC-15:?3 A?/ AC 250 V; DC-13:?2 A?/ DC 24 V
Recommended minimum load10 V?/ 10 mA;?24 V?/ 1 mA
Pull-in time (typ.)15ms
Drop-out time (typ.)25ms
Bounce time (typ.)3.5ms
Electrical life (NO; resistive load; 23 °C)50?x 103 switching operations
Mechanical life5?x 10? switching operations
Switching frequency with/without load (max.)6 min-1/ 180 min-1
Status indicatorRed LED