Product Model
150-C85NBD
Material Number
—
Manufacturer
ROCKWELL
Product ID
108621

Get a Free Quote

Request pricing and availability for 150-C85NBD.

More parts to source? Send your whole list in one enquiry

Key specifications

Voltage type for actuating
AC/DC
Rated operating voltage Ue
200
DV/DT protection
1000V/μs for power circuit
Operating frequency
50/60 Hz per UL/CSA/NEMA for power circuit
Rated operational current, max
TB-97, -98 (OVLD/Fault): 0.6A @ 120V AC and 0.3A @ 240V AC for auxiliary contacts
Weight
3.338
See all specifications

Product Highlights

  1. Soft Start and Soft Stop: SMC-3 controller with single-direction operation, selectable start times of 2, 5, 10, 15, 20, 25, or 30 s, and selectable soft stop of Off, 100%, 200%, or 300% of the start time setting when wired
  2. Integrated Motor Overload Protection: True motor overload protection with selectable trip class 10, 15, or 20 and normally open (N.O.) electromagnetic relay auxiliary contacts TB-97/-98 rated 1 A Ith and 0.6 A at 120 V AC or 0.3 A at 240 V AC
  3. Selectable Starting Parameters: Current limit of 150%, 250%, 350%, or 450% of full load current, initial torque of 15%, 25%, 35%, or 65% of locked rotor torque, and kick start of 0, 0.5, 1.0, or 1.5 s at 450% FLA
  4. Power Circuit Ratings: 3-phase only, rated operating voltage 200 V, insulation voltage 600 V AC per UL/CSA/NEMA, dielectric withstand 2500 V AC per IEC, rated impulse voltage 6 kV, repetitive peak voltage 1400 V per UL/CSA/NEMA, and 1000 V/µs DV/DT protection
  5. Control and Environmental Ratings: 100 V AC control supply at 50/60 Hz, AC/DC actuating voltage, IP2X protection, open-type enclosure, operating temperature -5 to 50 °C, humidity 5 to 95% noncondensing, altitude up to 2000 m, and pollution degree 2
150-C85NBD

Product Information

Technical Specifications

Specifications for 150-C85NBD

ParameterValue
With displayNo
Voltage type for actuatingAC/DC
Rated operating voltage Ue200
Rated control supply voltage at AC 50 Hz100
Rated control supply voltage at AC 60 Hz100
Controller typeSMC-3
DV/DT protection1000V/μs for power circuit
Repetitive peak voltage1400V per UL/CSA/NEMA for power circuit
Operating frequency50/60 Hz per UL/CSA/NEMA for power circuit
Overvoltage categoryIII per IEC for side mount auxiliary contacts
Rated impulse voltage6 kV for power circuit
Dielectric withstand2500V AC per IEC for power circuit
Insulation voltageRated 600V AC per UL/CSA/NEMA for power circuit
Rated operational voltage250V AC/30V DC per UL/CSA/NEMA for Side mount auxiliary contacts
Input OFF-state current<10 mA, <12 mA @ input OFF-state voltage (IN1, IN2) for control circuit
Short-circuit protection device listNon-time delay Thermal magnetic circuit breaker High capacity time delay class CC/J/L
Number of contactsTB-97, -98 (OVLD/Fault): 1 for auxiliary contacts
High capacity available fault current, max70kA @ 600V, maximum current 300 A time delay Class J or Class L fuse for inside delta connected motors
Type of currentTB-97, -98 (OVLD/Fault): AC/DC for auxiliary contacts
Conventional thermal current (Ith)TB-97, -98 (OVLD/Fault): 1 A for auxiliary contacts
Type of control circuitTB-97, -98 (OVLD/Fault): Electromagnetic relay for auxiliary contacts
Type of contactsTB-97, -98 (OVLD/Fault): Normally Open (N.O.) for auxiliary contacts
Utilization categoryTB-23, -24 (normal/up-to-speed), TB-33, -34 (normal/up-to-speed): C300/R150 per UL/CSA/NEMA for Side mount auxiliary contacts
Rated operational current, maxTB-97, -98 (OVLD/Fault): 0.6A @ 120V AC and 0.3A @ 240V AC for auxiliary contacts
Standard controller featureSoft stop
Integrated motor overload protectionYes
Short circuit protection device performance (SCPD) typeType 1
Selectable overload trip classTrip Class 10, 15, or 20
ParameterValue
Selectable start times2, 5, 10, 15, 20, 25, or 30 s
Input OFF-state voltage (IN1, IN2), max40V AC @ 17V DC/12V AC for control circuit
Selectable current limit150%, 250%, 350%, and 450% of full load current
Input ON-state voltage, during start (IN1, IN2)85V AC @ 19.2V DC/19.2V AC minimum for control circuit
Input ON-state current (IN1, IN2)9.8mA @ 120V AC/19.6mA @ 240V AC for control circuit, 7.3mA @ 24V AC/DC for control circuit
Degree of protection (IP)IP2X
ShockOpsal: 15 G
VibrationOpsal: 1.0 G peak, 0.15 mm (0.006 in) displacement
MakeTB-97, -98 (OVLD/Fault): 432VA for auxiliary contacts
BreakTB-97, -98 (OVLD/Fault): 72VA for auxiliary contacts
Internal bypassYes
FunctionSingle direction
Selectable kick start - 450% FLA0, 0.5, 1.0, or 1.5 s
Selectable initial torque15%, 25%, 35%, and 65% of locked rotor torque
Selectable soft stopOff, 100%, 200%, or 300% of the start time setting when wired
Storage and transportation temperature-25 °C
Rated surrounding temperature range without derating-5 °C
Humidity5...95% noncondensing
Operating temperatureOpen: -5 to 50 °C (23 to 122 °F)
EMC emission levelsRadiated emission: Class A per IEC
EMC immunity levelsSurge transient: per EN/IEC 60947-4-2 per IEC
Altitude2000 m
Pollution degree2
Number of polesEquipment is designed for 3-phase only for power circuit
EnclosureOpen type
RepairableNOT_REPAIRABLE
Preferred Availabilitytrue
Quick Turnaroundfalse
Dimension Height13.97
Lead Time92
Dimension Width29.972
Dimension Length22.606
Stock StatusSTOCKED
Weight3.338
Weight UnitKG