Q1Can you supply the ROCKWELL 150-C85NCD?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the ROCKWELL 150-C85NCD cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
150-C85NCD
Material Number
—
Manufacturer
ROCKWELL
Product ID
108254

Get a Free Quote

Request pricing and availability for 150-C85NCD.

More parts to source? Send your whole list in one enquiry

Key specifications

Voltage type for actuating
AC/DC
Rated operating voltage Ue
200
DV/DT protection
1000V/μs for power circuit
Operating frequency
50/60 Hz per UL/CSA/NEMA for power circuit
Rated operational current, max
TB-97, -98 (OVLD/Fault): 0.6A @ 120V AC and 0.3A @ 240V AC for auxiliary contacts
Weight
3.334
See all specifications

Product Highlights

  1. Current Rating: Handles up to 85 A at 600 V AC for power circuit applications
  2. Control Voltage: Operates on 100-240 V AC at 50/60 Hz
  3. Motor Protection: Integrated overload protection with selectable trip class 10, 15, or 20
  4. Starting Control: Selectable start times of 2, 5, 10, 15, 20, 25, or 30 s and current limits of 150%, 250%, 350%, or 450% of full load current
  5. Soft Stop: Standard soft stop function with selectable settings of off, 100%, 200%, or 300% of the start time
  6. Internal Bypass: Built-in bypass for efficient operation
  7. Auxiliary Contacts: One normally open (N.O.) overload/fault contact rated 0.6 A at 120 V AC and 0.3 A at 240 V AC
  8. Short-Circuit Protection: Type 1 coordination with maximum available fault current of 70 kA at 600 V
  9. Environmental Rating: Open type enclosure with IP2X protection and operating temperature range of -5 to 50 °C
150-C85NCD

Product Information

Technical Specifications

Specifications for 150-C85NCD

ParameterValue
With displayNo
Voltage type for actuatingAC/DC
Rated operating voltage Ue200
Rated control supply voltage at AC 50 Hz100
Rated control supply voltage at AC 60 Hz100
Controller typeSMC-3
DV/DT protection1000V/μs for power circuit
Repetitive peak voltage1600V per UL/CSA/NEMA for power circuit
Operating frequency50/60 Hz per UL/CSA/NEMA for power circuit
Overvoltage categoryIII per IEC for side mount auxiliary contacts
Rated impulse voltage6 kV for power circuit
Dielectric withstand2500V AC per IEC for power circuit
Insulation voltageRated 600V AC per UL/CSA/NEMA for power circuit
Rated operational voltage250V AC/30V DC per UL/CSA/NEMA for Side mount auxiliary contacts
Input OFF-state current<10 mA, <12 mA @ input off-state voltage (IN1, IN2) for control circuit
Short-circuit protection device listNon-time delay Thermal magnetic circuit breaker High capacity time delay class CC/J/L
Number of contactsTB-97, -98 (OVLD/Fault): 1 for auxiliary contacts
High capacity available fault current, max70kA @ 600V, maximum current 300 A time delay Class J or Class L fuse for inside delta connected motors
Type of currentTB-97, -98 (OVLD/Fault): AC/DC for auxiliary contacts
Conventional thermal current (Ith)TB-97, -98 (OVLD/Fault): 1 A for auxiliary contacts
Type of control circuitTB-97, -98 (OVLD/Fault): Electromagnetic relay for auxiliary contacts
Type of contactsTB-97, -98 (OVLD/Fault): Normally Open (N.O.) for auxiliary contacts
Utilization categoryTB-23, -24 (normal/up-to-speed), TB-33, -34 (normal/up-to-speed): C300/R150 per UL/CSA/NEMA for Side mount auxiliary contacts
Rated operational current, maxTB-97, -98 (OVLD/Fault): 0.6A @ 120V AC and 0.3A @ 240V AC for auxiliary contacts
Standard controller featureSoft stop
Integrated motor overload protectionYes
Short circuit protection device performance (SCPD) typeType 1
Selectable overload trip classTrip Class 10, 15, or 20
ParameterValue
Selectable start times2, 5, 10, 15, 20, 25, or 30 s
Input OFF-state voltage (IN1, IN2), max40V AC @ 17V DC/12V AC for control circuit
Selectable current limit150%, 250%, 350%, and 450% of full load current
Input ON-state voltage, during start (IN1, IN2)85V AC @ 19.2V DC/19.2V AC minimum for control circuit
Input ON-state current (IN1, IN2)9.8mA @ 120V AC/19.6mA @ 240V AC for control circuit, 7.3mA @ 24V AC/DC for control circuit
Degree of protection (IP)IP2X
ShockOpsal: 15 G
VibrationOpsal: 1.0 G peak, 0.15 mm (0.006 in) displacement
MakeTB-97, -98 (OVLD/Fault): 432VA for auxiliary contacts
BreakTB-97, -98 (OVLD/Fault): 72VA for auxiliary contacts
Internal bypassYes
FunctionSingle direction
Selectable kick start - 450% FLA0, 0.5, 1.0, or 1.5 s
Selectable initial torque15%, 25%, 35%, and 65% of locked rotor torque
Selectable soft stopOff, 100%, 200%, or 300% of the start time setting when wired
Storage and transportation temperature-25 °C
Rated surrounding temperature range without derating-5 °C
Humidity5...95% noncondensing
Operating temperatureOpen: -5 to 50 °C (23 to 122 °F)
EMC emission levelsRadiated emission: Class A per IEC
EMC immunity levelsSurge transient: per EN/IEC 60947-4-2 per IEC
Altitude2000 m
Pollution degree2
Number of polesEquipment is designed for 3-phase only for power circuit
EnclosureOpen type
RepairableNOT_REPAIRABLE
Preferred Availabilityfalse
Quick Turnaroundfalse
Dimension Height14.707
Lead Time5
Dimension Width21.412
Dimension Length30.201
Stock StatusNON_STOCKED
Weight3.334
Weight UnitKG
Dimension UnitCM

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.