Q1Can you supply the ROCKWELL 150-C85NCR?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the ROCKWELL 150-C85NCR cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
150-C85NCR
Material Number
—
Manufacturer
ROCKWELL
Product ID
108831

Get a Free Quote

Request pricing and availability for 150-C85NCR.

More parts to source? Send your whole list in one enquiry

Key specifications

Voltage type for actuating
AC/DC
Rated operating voltage Ue
200 V
Operating frequency
50/60 Hz per UL/CSA/NEMA for power circuit
Rated control power during start with fan
200mA @ 120V AC/100mA @ 240V AC, 700mA @ 24V AC/DC
Rated operational current, max
TB-97, -98 (OVLD/Fault): 0.6A @ 120V AC and 0.3A @ 240V AC for auxiliary contacts
Weight
3.3
See all specifications

Product Highlights

  1. Power Ratings: Line-connected motor power up to 55 kW at 500 V AC 50 Hz 3-phase, with line current 28.3 to 85 A and delta current 50 to 147 A at 500/575 V AC
  2. Protection and Overload: Integrated motor overload protection with selectable Trip Class 10, 15, or 20, plus DV/DT protection of 1000 V/µs and repetitive peak voltage of 1600 V for the power circuit
  3. Starting and Stopping Control: Selectable start times of 2, 5, 10, 15, 20, 25, or 30 s, kick start of 0, 0.5, 1.0, or 1.5 s at 450% FLA, initial torque of 15%, 25%, 35%, or 65% of locked rotor torque, current limit of 150%, 250%, 350%, or 450% of full load current, and soft stop
  4. Control and Auxiliary Contacts: 24 V AC/DC control supply, 200 V rated operating voltage, and one normally open electromagnetic relay auxiliary contact (TB-97/-98) rated 0.6 A at 120 V AC and 0.3 A at 240 V AC
  5. Physical and Environmental: Open-type enclosure, IP2X, 72 mm width, 130 mm depth, 206 mm height, 3.3 kg, operating temperature -5 to 50 °C, and 5 to 95% noncondensing humidity
150-C85NCR

Product Information

Technical Specifications

Specifications for 150-C85NCR

ParameterValue
With displayFalse
Voltage type for actuatingAC/DC
Rated operating voltage Ue200 V
Rated control supply voltage at AC 50 Hz24 V
Rated control supply voltage at AC 60 Hz24 V
Overload current28.3 A
Controller typeSMC-3
DV/DT protection1000V/μs for power circuit
Repetitive peak voltage1600V per UL/CSA/NEMA for power circuit
Operating frequency50/60 Hz per UL/CSA/NEMA for power circuit
Line connected motor power, max55 kW @ 500V AC @ 50Hz, 3-phase
Delta connected motor power, max40...150Hp @ 575V AC, 60 Hz, 3-phase
Overvoltage categoryIII per IEC for side mount auxiliary contacts
Rated impulse voltage6 kV for power circuit
Dielectric withstand2500V AC per IEC for power circuit
Line connected motor current28.3...85A @ 500/575V AC, 3-phase
Delta connected motor current50...147A @ 500/575V AC, 3-phase
Insulation voltageRated 600V AC per UL/CSA/NEMA for power circuit
Rated operational voltage250V AC/30V DC per UL/CSA/NEMA for Side mount auxiliary contacts
Rated control power during start with fan200mA @ 120V AC/100mA @ 240V AC, 700mA @ 24V AC/DC
Input OFF-state current<10 mA, <12 mA @ input off-state voltage (IN1, IN2) for control circuit
Short-circuit protection device listNon-time delay Thermal magnetic circuit breaker High capacity time delay class CC/J/L
Number of contactsTB-97, -98 (OVLD/Fault): 1 for auxiliary contacts
High capacity available fault current, max70kA @ 600V, maximum current 300 A time delay Class J or Class L fuse for inside delta connected motors
Type of currentTB-97, -98 (OVLD/Fault): AC/DC for auxiliary contacts
Conventional thermal current (Ith)TB-97, -98 (OVLD/Fault): 1 A for auxiliary contacts
Type of control circuitTB-97, -98 (OVLD/Fault): Electromagnetic relay for auxiliary contacts
Type of contactsTB-97, -98 (OVLD/Fault): Normally Open (N.O.) for auxiliary contacts
Utilization categoryTB-23, -24 (normal/up-to-speed), TB-33, -34 (normal/up-to-speed): C300/R150 per UL/CSA/NEMA for Side mount auxiliary contacts
Rated operational current, maxTB-97, -98 (OVLD/Fault): 0.6A @ 120V AC and 0.3A @ 240V AC for auxiliary contacts
Standard controller featureSoft stop
Standard available fault current, max10 kA @ maximum standard fuse 400 A for delta device opsal current rating
Rated control supply voltage at DC24 V
Integrated motor overload protectionTrue
ParameterValue
Short circuit protection device performance (SCPD) typeType 1
Selectable overload trip classTrip Class 10, 15, or 20
Selectable start times2, 5, 10, 15, 20, 25, or 30 s
Input OFF-state voltage (IN1, IN2), max40V AC @ 17V DC/12V AC for control circuit
Selectable current limit150%, 250%, 350%, and 450% of full load current
Input ON-state voltage, during start (IN1, IN2)85V AC @ 19.2V DC/19.2V AC minimum for control circuit
Input ON-state current (IN1, IN2)9.8mA @ 120V AC/19.6mA @ 240V AC for control circuit, 7.3mA @ 24V AC/DC for control circuit
Degree of protection (IP)IP2X
Weight3.3
ShockOpsal: 15 G
Width72 mm (2.83 in)
Depth130 mm (5.12 in)
Height206 mm (8.11 in)
Cable size2.5...95 mm2 (14...3 AWG) for line power terminals
VibrationOpsal: 1.0 G peak, 0.15 mm (0.006 in) displacement
MakeTB-97, -98 (OVLD/Fault): 432VA for auxiliary contacts
BreakTB-97, -98 (OVLD/Fault): 72VA for auxiliary contacts
Tightening torque11.3...12.4 Nm (100...110 in-lb) for load power terminals
Internal bypassTrue
FunctionSingle direction
Selectable kick start - 450% FLA0, 0.5, 1.0, or 1.5 s
Selectable initial torque15%, 25%, 35%, and 65% of locked rotor torque
Selectable soft stopOff, 100%, 200%, or 300% of the start time setting when wired
Steady state heat dissipation82 W
Storage and transportation temperature-25 °C
Rated surrounding temperature range without derating-5 °C
Humidity5...95% noncondensing
Operating temperatureOpen: -5 to 50 °C (23 to 122 °F)
EMC emission levelsRadiated emission: Class A per IEC
EMC immunity levelsSurge transient: per EN/IEC 60947-4-2 per IEC
Altitude2000 m
Pollution degree2 None
Mounting hole size5.3 mm
Number of polesEquipment is designed for 3-phase only for power circuit
EnclosureOpen type
RepairableNOT_REPAIRABLE
Preferred Availabilityfalse
Quick Turnaroundfalse
Dimension Height15.001
Lead Time73
Dimension Width21.001
Dimension Length30.0
Stock StatusNON_STOCKED
Weight UnitKG
Dimension UnitCM