Industrial Automation Parts. Prompt replies from real people.

ROCKWELL 150-C43NBD SMC-3 Smart Motor Controller

  • Warehouse stock, ready to ship
  • Fully genuine original parts
  • Free quotes within 24 hours
Get a Free Quote

Free quote · Reply within 24 hours

Last Updated: 11/25/2026

Q1Can you supply the ROCKWELL 150-C43NBD?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the ROCKWELL 150-C43NBD cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
150-C43NBD
Material Number
—
Manufacturer
ROCKWELL
Product ID
106652

Get a Free Quote

Request pricing and availability for 150-C43NBD.

More parts to source? Send your whole list in one enquiry

Key specifications

Voltage type for actuating
AC/DC
Rated operating voltage Ue
200
DV/DT protection
1000V/μs for power circuit
Operating frequency
50/60 Hz per UL/CSA/NEMA for power circuit
Rated operational current, max
TB-97, -98 (OVLD/Fault): 0.6A @ 120V AC and 0.3A @ 240V AC for auxiliary contacts
Weight
3.567
See all specifications

Product Highlights

  1. Current Rating: 43 A, suitable for line-connected motors up to 90 A when protected by a Class J or L time-delay fuse
  2. Control Voltage: 100 V AC at 50 Hz and 100 V AC at 60 Hz, with AC/DC actuating voltage
  3. Motor Protection: Integrated overload protection with selectable Trip Class 10, 15, or 20 and Type 1 short-circuit protection device performance
  4. Starting and Stopping: Selectable start times of 2, 5, 10, 15, 20, 25, or 30 s, selectable current limit of 150%, 250%, 350%, or 450% of full load current, selectable kick start of 0, 0.5, 1.0, or 1.5 s at 450% FLA, selectable initial torque of 15%, 25%, 35%, or 65% of locked rotor torque, and soft stop
  5. Power Circuit Ratings: 200 V rated operating voltage, 600 V AC insulation voltage, 6 kV rated impulse voltage, 2500 V AC dielectric withstand, and 1400 V repetitive peak voltage per UL/CSA/NEMA
  6. Operating Conditions: Open-type enclosure, -5 to 50 °C operating temperature, 5 to 95% noncondensing humidity, IP2X protection, and 2000 m maximum altitude
150-C43NBD

Product Information

Technical Specifications

Specifications for 150-C43NBD

ParameterValue
With displayNo
Voltage type for actuatingAC/DC
Rated operating voltage Ue200
Rated control supply voltage at AC 50 Hz100
Rated control supply voltage at AC 60 Hz100
Controller typeSMC-3
DV/DT protection1000V/μs for power circuit
Repetitive peak voltage1400V per UL/CSA/NEMA for power circuit
Operating frequency50/60 Hz per UL/CSA/NEMA for power circuit
Overvoltage categoryIII per IEC for side mount auxiliary contacts
Rated impulse voltage6 kV for power circuit
Dielectric withstand2500V AC per IEC for power circuit
Insulation voltageRated 600V AC per UL/CSA/NEMA for power circuit
Rated operational voltage250V AC/30V DC per UL/CSA/NEMA for Side mount auxiliary contacts
Input OFF-state current<10 mA, <12 mA @ input OFF-state voltage (IN1, IN2) for control circuit
Short-circuit protection device listNon-time delay Thermal magnetic circuit breaker High capacity time delay class CC/J/L
Number of contactsTB-97, -98 (OVLD/Fault): 1 for auxiliary contacts
High capacity available fault current, max70kA @ 600V, maximum current 90 A time delay Class J or Class L fuse for line connected motors
Type of currentTB-97, -98 (OVLD/Fault): AC/DC for auxiliary contacts
Conventional thermal current (Ith)TB-97, -98 (OVLD/Fault): 1 A for auxiliary contacts
Type of control circuitTB-97, -98 (OVLD/Fault): Electromagnetic relay for auxiliary contacts
Type of contactsTB-97, -98 (OVLD/Fault): Normally Open (N.O.) for auxiliary contacts
Utilization categoryTB-23, -24 (normal/up-to-speed), TB-33, -34 (normal/up-to-speed): C300/R150 per UL/CSA/NEMA for Side mount auxiliary contacts
Rated operational current, maxTB-97, -98 (OVLD/Fault): 0.6A @ 120V AC and 0.3A @ 240V AC for auxiliary contacts
Standard controller featureSoft stop
Standard available fault current, max10 kA @ maximum standard fuse 250 A for delta device opsal current rating
Integrated motor overload protectionYes
Short circuit protection device performance (SCPD) typeType 1
ParameterValue
Selectable overload trip classTrip Class 10, 15, or 20
Selectable start times2, 5, 10, 15, 20, 25, or 30 s
Input OFF-state voltage (IN1, IN2), max40V AC @ 17V DC/12V AC for control circuit
Selectable current limit150%, 250%, 350%, and 450% of full load current
Input ON-state voltage, during start (IN1, IN2)85V AC @ 19.2V DC/19.2V AC minimum for control circuit
Input ON-state current (IN1, IN2)9.8mA @ 120V AC/19.6mA @ 240V AC for control circuit, 7.3mA @ 24V AC/DC for control circuit
Degree of protection (IP)IP2X
ShockOpsal: 15 G
VibrationOpsal: 1.0 G peak, 0.15 mm (0.006 in) displacement
MakeTB-97, -98 (OVLD/Fault): 432VA for auxiliary contacts
BreakTB-97, -98 (OVLD/Fault): 72VA for auxiliary contacts
Internal bypassYes
FunctionSingle direction
Selectable kick start - 450% FLA0, 0.5, 1.0, or 1.5 s
Selectable initial torque15%, 25%, 35%, and 65% of locked rotor torque
Selectable soft stopOff, 100%, 200%, or 300% of the start time setting when wired
Storage and transportation temperature-25 °C
Rated surrounding temperature range without derating-5 °C
Humidity5...95% noncondensing
Operating temperatureOpen: -5 to 50 °C (23 to 122 °F)
EMC emission levelsRadiated emission: Class A per IEC
EMC immunity levelsSurge transient: per EN/IEC 60947-4-2 per IEC
Altitude2000 m
Pollution degree2
Number of polesEquipment is designed for 3-phase only for power circuit
EnclosureOpen type
RepairableNOT_REPAIRABLE
Preferred Availabilitytrue
Quick Turnaroundfalse
Dimension Height22.098
Lead Time5
Dimension Width26.67
Dimension Length30.988
Stock StatusSTOCKED
Weight3.567
Weight UnitKG
Dimension UnitCM

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.

Need Help Checking This Part?

Ask about specifications, condition or a suitable alternative.

Contact Us on WhatsApp
WhatsApp