Industrial Automation Parts. Prompt replies from real people.

ROCKWELL 150-C43NBR Smart Motor Controller

  • Warehouse stock, ready to ship
  • Fully genuine original parts
  • Free quotes within 24 hours
Get a Free Quote

Free quote · Reply within 24 hours

Last Updated: 11/25/2026

Q1Can you supply the ROCKWELL 150-C43NBR?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the ROCKWELL 150-C43NBR cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
150-C43NBR
Material Number
—
Manufacturer
ROCKWELL
Product ID
105818

Get a Free Quote

Request pricing and availability for 150-C43NBR.

More parts to source? Send your whole list in one enquiry

Key specifications

Voltage type for actuating
AC/DC
Rated operating voltage Ue
200
DV/DT protection
1000V/μs for power circuit
Operating frequency
50/60 Hz per UL/CSA/NEMA for power circuit
Rated operational current, max
TB-97, -98 (OVLD/Fault): 0.6A @ 120V AC and 0.3A @ 240V AC for auxiliary contacts
Weight
3.329
See all specifications

Product Highlights

  1. Motor Protection: Integrated motor overload protection with selectable trip class 10, 15, or 20 and selectable current limit of 150%, 250%, 350%, or 450% of full load current
  2. Starting and Stopping Control: Single-direction controller with selectable start times of 2, 5, 10, 15, 20, 25, or 30 s, selectable initial torque of 15%, 25%, 35%, or 65% of locked rotor torque, selectable kick start at 450% FLA for 0, 0.5, 1.0, or 1.5 s, and soft stop
  3. Control Circuit: 24 V AC/DC control supply voltage with input ON-state current of 7.3 mA at 24 V AC/DC and OFF-state current below 10 mA
  4. Power Circuit Ratings: 200 V rated operating voltage, 50/60 Hz operating frequency, 600 V AC insulation voltage, 6 kV rated impulse voltage, 2500 V AC dielectric withstand, and 1000 V/µs DV/DT protection
  5. Auxiliary Contacts: One normally open electromagnetic relay contact (TB-97, -98) for overload and fault signaling, rated 0.6 A at 120 V AC and 0.3 A at 240 V AC, with 432 VA make and 72 VA break
  6. Short-Circuit Protection: Type 1 SCPD coordination with high available fault current up to 70 kA at 600 V using a 90 A time-delay Class J or Class L fuse, and 10 kA with a maximum 250 A standard fuse
  7. Environmental and Mounting: Open-type enclosure with IP2X protection, operating temperature -5 to 50 °C, humidity 5 to 95% noncondensing, altitude up to 2000 m, pollution degree 2, and resistance to 15 G shock and 1.0 G peak vibration
150-C43NBR

Product Information

Technical Specifications

Specifications for 150-C43NBR

ParameterValue
With displayNo
Voltage type for actuatingAC/DC
Rated operating voltage Ue200
Rated control supply voltage at AC 50 Hz24 V
Rated control supply voltage at AC 60 Hz24 V
Controller typeSMC-3
DV/DT protection1000V/μs for power circuit
Repetitive peak voltage1400V per UL/CSA/NEMA for power circuit
Operating frequency50/60 Hz per UL/CSA/NEMA for power circuit
Overvoltage categoryIII per IEC for side mount auxiliary contacts
Rated impulse voltage6 kV for power circuit
Dielectric withstand2500V AC per IEC for power circuit
Insulation voltageRated 600V AC per UL/CSA/NEMA for power circuit
Rated operational voltage250V AC/30V DC per UL/CSA/NEMA for Side mount auxiliary contacts
Input OFF-state current<10 mA, <12 mA @ input OFF-state voltage (IN1, IN2) for control circuit
Short-circuit protection device listNon-time delay Thermal magnetic circuit breaker High capacity time delay class CC/J/L
Number of contactsTB-97, -98 (OVLD/Fault): 1 for auxiliary contacts
High capacity available fault current, max70kA @ 600V, maximum current 90 A time delay Class J or Class L fuse for line connected motors
Type of currentTB-97, -98 (OVLD/Fault): AC/DC for auxiliary contacts
Conventional thermal current (Ith)TB-97, -98 (OVLD/Fault): 1 A for auxiliary contacts
Type of control circuitTB-97, -98 (OVLD/Fault): Electromagnetic relay for auxiliary contacts
Type of contactsTB-97, -98 (OVLD/Fault): Normally Open (N.O.) for auxiliary contacts
Utilization categoryTB-23, -24 (normal/up-to-speed), TB-33, -34 (normal/up-to-speed): C300/R150 per UL/CSA/NEMA for Side mount auxiliary contacts
Rated operational current, maxTB-97, -98 (OVLD/Fault): 0.6A @ 120V AC and 0.3A @ 240V AC for auxiliary contacts
Standard controller featureSoft stop
Standard available fault current, max10 kA @ maximum standard fuse 250 A for delta device opsal current rating
Rated control supply voltage at DC24 V
Integrated motor overload protectionYes
Short circuit protection device performance (SCPD) typeType 1
ParameterValue
Selectable overload trip classTrip Class 10, 15, or 20
Selectable start times2, 5, 10, 15, 20, 25, or 30 s
Input OFF-state voltage (IN1, IN2), max40V AC @ 17V DC/12V AC for control circuit
Selectable current limit150%, 250%, 350%, and 450% of full load current
Input ON-state voltage, during start (IN1, IN2)85V AC @ 19.2V DC/19.2V AC minimum for control circuit
Input ON-state current (IN1, IN2)9.8mA @ 120V AC/19.6mA @ 240V AC for control circuit, 7.3mA @ 24V AC/DC for control circuit
Degree of protection (IP)IP2X
ShockOpsal: 15 G
VibrationOpsal: 1.0 G peak, 0.15 mm (0.006 in) displacement
MakeTB-97, -98 (OVLD/Fault): 432VA for auxiliary contacts
BreakTB-97, -98 (OVLD/Fault): 72VA for auxiliary contacts
Internal bypassYes
FunctionSingle direction
Selectable kick start - 450% FLA0, 0.5, 1.0, or 1.5 s
Selectable initial torque15%, 25%, 35%, and 65% of locked rotor torque
Selectable soft stopOff, 100%, 200%, or 300% of the start time setting when wired
Storage and transportation temperature-25 °C
Rated surrounding temperature range without derating-5 °C
Humidity5...95% noncondensing
Operating temperatureOpen: -5 to 50 °C (23 to 122 °F)
EMC emission levelsRadiated emission: Class A per IEC
EMC immunity levelsSurge transient: per EN/IEC 60947-4-2 per IEC
Altitude2000 m
Pollution degree2
Number of polesEquipment is designed for 3-phase only for power circuit
EnclosureOpen type
RepairableNOT_REPAIRABLE
Preferred Availabilitytrue
Quick Turnaroundfalse
Dimension Height14.402
Lead Time5
Dimension Width29.896
Dimension Length21.692
Stock StatusSTOCKED
Weight3.329
Weight UnitKG
Dimension UnitCM

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.

Need Help Checking This Part?

Ask about specifications, condition or a suitable alternative.

Contact Us on WhatsApp
WhatsApp