Product Model
150-C43NCR
Material Number
—
Manufacturer
ROCKWELL
Product ID
107396

Get a Free Quote

Request pricing and availability for 150-C43NCR.

More parts to source? Send your whole list in one enquiry

Key specifications

Voltage type for actuating
AC/DC
Rated operating voltage Ue
200
DV/DT protection
1000V/μs for power circuit
Operating frequency
50/60 Hz per UL/CSA/NEMA for power circuit
Rated operational current, max
TB-97, -98 (OVLD/Fault): 0.6A @ 120V AC and 0.3A @ 240V AC for auxiliary contacts
Weight
3.384
See all specifications

Product Highlights

  1. Motor Control Functions: SMC-3 controller for single-direction 3-phase motors with soft stop, selectable kickstart (0, 0.5, 1.0, or 1.5 s at 450% FLA), selectable initial torque (15%, 25%, 35%, or 65% of locked rotor torque), selectable current limit (150%, 250%, 350%, or 450% of full load current), and selectable start times (2, 5, 10, 15, 20, 25, or 30 s)
  2. Overload and Short-Circuit Protection: Integrated motor overload protection with selectable Trip Class 10, 15, or 20, Type 1 short-circuit protection device performance, and high available fault current up to 70 kA at 600 V with a 90 A time delay Class J or Class L fuse for line-connected motors
  3. Power Circuit Ratings: Rated 600 V AC insulation voltage per UL/CSA/NEMA, 2500 V AC dielectric withstand per IEC, 1600 V repetitive peak voltage per UL/CSA/NEMA, 6 kV rated impulse voltage, 1000 V/µs DV/DT protection, and 50/60 Hz operating frequency
  4. Control Circuit: 24 V AC/DC control supply voltage, input ON-state current of 7.3 mA at 24 V AC/DC, input OFF-state current below 10 mA, and input OFF-state voltage up to 40 V AC
  5. Auxiliary Contacts: One normally open (N.O.) overload/fault contact TB-97/-98 rated 1 A conventional thermal current, 0.6 A at 120 V AC and 0.3 A at 240 V AC, with C300/R150 utilization category
  6. Environmental and Mounting: Open-type enclosure with IP2X degree of protection, operating temperature of -5 to 50 °C, storage and transportation temperature of -25 °C, humidity 5 to 95% noncondensing, altitude up to 2000 m, pollution degree 2, and 15 G shock and 1.0 G peak vibration resistance
150-C43NCR

Product Information

Technical Specifications

Specifications for 150-C43NCR

ParameterValue
With displayNo
Voltage type for actuatingAC/DC
Rated operating voltage Ue200
Rated control supply voltage at AC 50 Hz24 V
Rated control supply voltage at AC 60 Hz24 V
Controller typeSMC-3
DV/DT protection1000V/μs for power circuit
Repetitive peak voltage1600V per UL/CSA/NEMA for power circuit
Operating frequency50/60 Hz per UL/CSA/NEMA for power circuit
Overvoltage categoryIII per IEC for side mount auxiliary contacts
Rated impulse voltage6 kV for power circuit
Dielectric withstand2500V AC per IEC for power circuit
Insulation voltageRated 600V AC per UL/CSA/NEMA for power circuit
Rated operational voltage250V AC/30V DC per UL/CSA/NEMA for Side mount auxiliary contacts
Input OFF-state current<10 mA, <12 mA @ input off-state voltage (IN1, IN2) for control circuit
Short-circuit protection device listNon-time delay Thermal magnetic circuit breaker High capacity time delay class CC/J/L
Number of contactsTB-97, -98 (OVLD/Fault): 1 for auxiliary contacts
High capacity available fault current, max70kA @ 600V, maximum current 90 A time delay Class J or Class L fuse for line connected motors
Type of currentTB-97, -98 (OVLD/Fault): AC/DC for auxiliary contacts
Conventional thermal current (Ith)TB-97, -98 (OVLD/Fault): 1 A for auxiliary contacts
Type of control circuitTB-97, -98 (OVLD/Fault): Electromagnetic relay for auxiliary contacts
Type of contactsTB-97, -98 (OVLD/Fault): Normally Open (N.O.) for auxiliary contacts
Utilization categoryTB-23, -24 (normal/up-to-speed), TB-33, -34 (normal/up-to-speed): C300/R150 per UL/CSA/NEMA for Side mount auxiliary contacts
Rated operational current, maxTB-97, -98 (OVLD/Fault): 0.6A @ 120V AC and 0.3A @ 240V AC for auxiliary contacts
Standard controller featureSoft stop
Standard available fault current, max10 kA @ maximum standard fuse 250 A for delta device opsal current rating
Rated control supply voltage at DC24 V
Integrated motor overload protectionYes
Short circuit protection device performance (SCPD) typeType 1
ParameterValue
Selectable overload trip classTrip Class 10, 15, or 20
Selectable start times2, 5, 10, 15, 20, 25, or 30 s
Input OFF-state voltage (IN1, IN2), max40V AC @ 17V DC/12V AC for control circuit
Selectable current limit150%, 250%, 350%, and 450% of full load current
Input ON-state voltage, during start (IN1, IN2)85V AC @ 19.2V DC/19.2V AC minimum for control circuit
Input ON-state current (IN1, IN2)9.8mA @ 120V AC/19.6mA @ 240V AC for control circuit, 7.3mA @ 24V AC/DC for control circuit
Degree of protection (IP)IP2X
ShockOpsal: 15 G
VibrationOpsal: 1.0 G peak, 0.15 mm (0.006 in) displacement
MakeTB-97, -98 (OVLD/Fault): 432VA for auxiliary contacts
BreakTB-97, -98 (OVLD/Fault): 72VA for auxiliary contacts
Internal bypassYes
FunctionSingle direction
Selectable kick start - 450% FLA0, 0.5, 1.0, or 1.5 s
Selectable initial torque15%, 25%, 35%, and 65% of locked rotor torque
Selectable soft stopOff, 100%, 200%, or 300% of the start time setting when wired
Storage and transportation temperature-25 °C
Rated surrounding temperature range without derating-5 °C
Humidity5...95% noncondensing
Operating temperatureOpen: -5 to 50 °C (23 to 122 °F)
EMC emission levelsRadiated emission: Class A per IEC
EMC immunity levelsSurge transient: per EN/IEC 60947-4-2 per IEC
Altitude2000 m
Pollution degree2
Number of polesEquipment is designed for 3-phase only for power circuit
EnclosureOpen type
RepairableNOT_REPAIRABLE
Preferred Availabilityfalse
Quick Turnaroundfalse
Dimension Height27.889
Lead Time74
Dimension Width18.999
Dimension Length25.4
Stock StatusNON_STOCKED
Weight3.384
Weight UnitKG
Dimension UnitCM

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.