- 150-F201NZDB
The Rockwell Allen-Bradley 150-F201NZDB is an SMC Flex soft starter with an integrated display. It operates on 100...240 V AC control voltage and 230 V rated operating voltage, with 50/60 Hz power circuit operating frequency. The controller is rated 201 A, 75-150 Hp at 460 V AC, and supports line-connected motor power up to 75 Hp at 230 V AC, 60 Hz, three-phase, and delta-connected motor power up to 350 Hp at 575 V AC, 60 Hz, three-phase. Overload current is 67 A for line-connected devices and 116 A for delta-connected devices. Trip classes are 10, 15, 20, and 30, with trip current at 117% of motor FLC. Control options include pump control.
- 150-F201NZDD
The Rockwell Allen-Bradley 150-F201NZDD is an SMC Flex soft starter with an open-type enclosure, display, and internal bypass. It is rated 201 A and 75–150 Hp at 460 V AC, with a rated operating voltage of 230 V and a rated operational voltage of 230...690 V/Y (-15%, +10%) per IEC for the power circuit. Control voltage is 100...240 V AC, and operating frequency is 50/60 Hz for the power circuit. Line-connected motor current is 67...201 A at 600/Y/690 V AC, three-phase; delta-connected motor current is 116...348 A at 500/575 V AC, three-phase. Integrated motor overload protection is included, with trip classes 10, 15, 20, and 30. Dimensions are 225 mm wide, 253.8 mm deep, and 560 mm high.
- 150-F251NBD
Product identification: ROCKWELL 150-F251NBD. The Allen-Bradley 150-F251NBD is an SMC Flex soft starter with a 251 A controller rating, corresponding to 100–200 HP at 460 V AC. It operates on a rated voltage of 200 V AC and accepts control supply voltages of 100–240 V AC at 50 Hz and 60 Hz. The unit includes a display and supports trip classes 10, 15, 20, and 30, with a trip current rating of 117% of motor full-load current. Overload current is 84 A for line-connected devices and 145 A for delta-connected devices. The power circuit uses an RC snubber network for DV/DT protection and has a repetitive peak inverse voltage rating of 1400 V per UL/CSA/NEMA. Maximum line-connected motor power is 75 kW at 230 V AC, 50 Hz, three-phase.
- 150-F251NBDD
The Rockwell Allen-Bradley 150-F251NBDD is an SMC Flex soft starter with a 251 A controller rating (100–200 HP at 460 V AC). It operates on 200–480 V AC input, with control voltage of 100–240 V AC and 50/60 Hz power-circuit operating frequency. The unit includes a display and supports brake control. Trip classes are 10, 15, 20, and 30, with trip current at 117% of motor FLC. Overload current is 84 A for line-connected devices and 145 A for delta-connected devices. The transformer control module is rated 75 VA at 100–240 V AC (-15%, +10%). Maximum line-connected motor power is 75 kW at 230 V AC, 50 Hz, 3-phase.
- 150-F251NBR
The Rockwell 150-F251NBR is an SMC Flex smart motor controller configured as a soft starter with integral bypass and single-direction function. It is rated 251 A, 100–200 HP at 460 V AC, three-phase, with a rated operational voltage of 200–480 V AC (-15%, +10%) per UL/CSA/NEMA for the power circuit. Control voltage is 24 V AC/DC. Line-connected motor current is 84–251 A at 600/Y/690 V AC, three-phase; delta-connected motor current is 145–435 A at 500/575 V AC, three-phase. Overload current is 84 A line-connected and 145 A delta-connected. Trip classes are 10, 15, 20, and 30. The controller includes a display, integrated motor overload protection, and status indication for stopped, starting, stopping, at speed, alarm, and fault.
- 150-F251NCD
The Rockwell 150-F251NCD is a SMC Flex soft starter with a 251 A controller rating for 100–200 HP motors at 460V AC. It has a rated operational voltage of 200...600V AC (-15%, +10%) per UL/CSA/NEMA for the power circuit, control voltage of 100...240V AC, and operates at 50/60 Hz. Line-connected motor current is 84...251 A at 600/Y/690V AC, 3-phase; delta-connected current is 145...435 A at 500/575V AC, 3-phase. It includes a display, integrated motor overload protection, internal bypass, and trip classes 10, 15, 20, and 30. Enclosure is open type, three poles, dimensions 225 mm width, 253.8 mm depth, 560 mm height.
- 150-F251NCDB
The Rockwell 150-F251NCDB is an SMC Flex smart motor controller configured as a soft starter with pump control and an integrated display. It is rated 251 A, 100–200 Hp at 460V AC, with a rated operational voltage of 200...600V AC (-15%, +10%) per UL/CSA/NEMA for the power circuit, and 50/60 Hz operating frequency. Line-connected motor current is 84...251 A at 600/Y/690V AC, 3-phase; delta-connected motor current is 145...435 A at 500/575V AC, 3-phase. Control voltage is 100...240V AC. Integrated motor overload protection is included, with trip classes 10, 15, 20 and 30. The open-type enclosure measures 225 mm wide, 253.8 mm deep and 560 mm high.
- 150-F251NCR
The Rockwell 150-F251NCR is a SMC Flex soft starter with an open-type enclosure, rated 251 A and 100–200 Hp at 460V AC. It operates on 200–600V AC (-15%, +10%) per UL/CSA/NEMA, 50/60 Hz, 3-phase, with 24V AC/DC control voltage. Line-connected motor current is 84–251 A at 600/Y/690V AC; delta-connected current is 145–435 A at 500/575V AC. It includes an integrated bypass, integrated motor overload protection, and a display. Trip classes are 10, 15, 20, and 30, with trip current at 117% of motor FLC. Dimensions are 225 mm wide, 253.8 mm deep, and 560 mm high. Operating temperature is -5 to 50 °C (23 to 122 °F).