- AF169P-G01
ABB AF169P-G01 is an industrial catalog item. Key specifications include Product Net Width: 86 mm, Product Net Height: 38 mm, Product Net Depth / Length: 86 mm, and Product Net Weight: 102.8 g. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- AF169P-PG01
ABB AF169P-PG01 is identified by manufacturer ID 2TCZ101063R1925. Its product net width is 86 mm, net height is 38 mm, and net depth or length is 86 mm. Product net weight is 102.8 g. No category, electrical ratings, performance specifications, standards, certifications, applications, or accessories are supplied in the available data, so none are stated here.
- AF16B-22-00-14
The ABB AF16B-22-00-14 is a 4-pole AC contactor with two normally open and two normally closed main contacts, and no auxiliary contacts. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.31 kg. The main circuit is rated 690 V at 50/60 Hz, with a rated insulation voltage of 690 V according to IEC 60947-4-1 and 600 V according to UL/CSA, and a rated impulse withstand voltage of 6 kV. AC-3 rated operational power is 7.5 kW at 380/400 V and 9 kW at 415, 440, 500, and 690 V. The control circuit operates at 250 to 500 V for 50 Hz, 60 Hz, and DC. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, and CSA C22.2 No. 60947-4-1.
- AF16B-22-00RT-14
The ABB AF16B-22-00RT-14 is a 4-pole AC contactor with 2 main contacts NO and 2 main contacts NC, and no auxiliary contacts. It has ring-tongue terminals and measures 45 mm wide, 77 mm deep, and 86 mm high, weighing 0.32 kg. The rated operational voltage of the main circuit is 690 V, with a rated impulse withstand voltage of 6 kV. Rated operational power AC-3 is 7.5 kW at 380/400 V and 9 kW at 415 V, 440 V, 500 V, and 690 V. The rated control circuit voltage is 250 to 500 V at 50 Hz, 60 Hz, and DC operation. It mounts on TH35-15 or TH35-7.5 DIN rail or with 2 x M4 screws placed diagonally.
- AF16B-30-01-14
The ABB AF16B-30-01-14 is a 3-pole AC contactor with three normally open main contacts and one normally closed auxiliary contact. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.31 kg. The contactor is rated for a main circuit operational voltage of 690 V and a frequency of 50/60 Hz. Its AC-3 rating at 380/400 V and 60 °C is 18 A and 7.5 kW; at 690 V and 60 °C, it is 10.5 A and 9 kW. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1. The manufacturer identifier is 1SBL177061R1401.
- AF16B-30-01K-14
ABB AF16B-30-01K-14 AC contactor, manufacturer ID 1SBL177063R1401. Three main contacts NO, zero main contacts NC, one auxiliary contact NC. Rated operational voltage 690 V for main and auxiliary circuits; rated frequency 50/60 Hz. Rated operational current AC-1 30 A at 690 V and 40 °C; AC-3 18 A at 415 V and 60 °C, 10.5 A at 690 V and 60 °C. Rated control circuit voltage 250 to 500 V at 50 Hz, 60 Hz, and DC operation. Push-in spring terminals, wire stripping length 10 mm. Dimensions 45 mm width, 77 mm depth, 92.3 mm height; weight 0.325 kg. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, IEC 61373.
- AF16B-30-01RT-14
The ABB AF16B-30-01RT-14 is a 3-pole AC contactor with three normally open main contacts and one normally closed auxiliary contact. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.32 kg. Main and auxiliary circuits are rated 690 V at 50/60 Hz. Rated operational power AC-3 is 7.5 kW at 380/400 V and 9 kW at 415 V, 440 V, 500 V, and 690 V, each at 60 °C. Rated insulation voltage is 690 V per IEC 60947-4-1 and 600 V per UL/CSA. Terminals are ring-tongue type, with IP10 protection on main, auxiliary, and coil terminals. Mounting is on TH35-15 or TH35-7.5 DIN rail per IEC 60715, or with two M4 screws placed diagonally.
- AF16B-30-10-14
The ABB AF16B-30-10-14 is a 3-pole AC contactor with three normally open main contacts and one normally open auxiliary contact. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.31 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 18 A at 380/400 V, 415 V, 440 V, and 220/230/240 V, 15 A at 500 V, and 10.5 A at 690 V, all at 60 °C. Rated operational power AC-3 is 7.5 kW at 380/400 V and 9 kW at 415 V, 440 V, 500 V, and 690 V. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.