- AF16B-30-10K-14
ABB AF16B-30-10K-14 is a 3-pole AC contactor, manufacturer ID 1SBL177063R1410. It has 3 main contacts NO, 0 main contacts NC, and 1 auxiliary contact NO. Dimensions are 45 mm wide, 77 mm deep, and 92.3 mm high, with a net weight of 0.325 kg. Rated operational voltage is 690 V for main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 18 A at 415 V and 440 V, 15 A at 500 V, and 10.5 A at 690 V, all at 60 °C. Rated operational power AC-3 is 7.5 kW at 380/400 V and 9 kW at 415 V, 440 V, 500 V, and 690 V. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AF16B-30-10RT-14
The ABB AF16B-30-10RT-14 is a 3-pole AC contactor with three normally open main contacts and one normally open auxiliary contact. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.32 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational power AC-3 is 7.5 kW at 380/400 V and 9 kW at 415, 440, 500, and 690 V. Rated operational current AC-3 at 60 °C is 18 A at 415 V and 10.5 A at 690 V. Terminals are ring-tongue type. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, IEC 60077-1 and IEC 60077-2 (applicable parts), EN 50155 (applicable parts), TR CU 001/2011, and IEC 61373.
- AF16B-40-00-14
The ABB AF16B-40-00-14 is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.31 kg. The main circuit is rated 690 V with a rated impulse withstand voltage of 6 kV. Per IEC 60947-4-1, conventional free-air thermal current is 35 A at 40 °C. AC-3 rated operational power is 7.5 kW at 380/400 V and 9 kW at 415, 440, 500, and 690 V. Control circuit voltage is 250 to 500 V at 50/60 Hz and for DC operation. Terminals are screw type, IP20. DIN-rail mounting is TH35-15 or TH35-7.5 per IEC 60715.
- AF16B-40-00RT-14
The ABB AF16B-40-00RT-14 is an AC contactor with four normally open main contacts and no auxiliary contacts. It has ring-tongue terminals and measures 45 mm wide, 77 mm deep, and 86 mm high, weighing 0.32 kg. The rated operational voltage of the main circuit is 690 V, and the rated control circuit voltage is 250 to 500 V at 50 Hz, 250 to 500 V at 60 Hz, and 250 to 500 V DC. Rated operational power AC-3 is 7.5 kW at 400 V and 9 kW at 415, 440, 500, and 690 V. Conventional free-air thermal current is 35 A at 40 °C. It mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715, or on two M4 screws placed diagonally. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AF16Z-22-00-20
ABB AF16Z-22-00-20 is a 4-pole AC contactor with two normally open and two normally closed main contacts, and no auxiliary contacts. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.31 kg. The main circuit is rated 690 V at 50/60 Hz, with a rated insulation voltage of 690 V according to IEC 60947-4-1 and 600 V according to UL/CSA, and a rated impulse withstand voltage of 6 kV. Conventional free-air thermal current is 35 A according to IEC 60947-4-1 for open contactors at 40 °C. AC-3 rated operational current is 18 A at 415 V and 60 °C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, CAN/CSA C22.2 No.60947-4-1.
- AF16Z-22-00-21
ABB AF16Z-22-00-21 is a 4-pole AC contactor, manufacturer ID 1SBL176501R2100. It has 2 main contacts NO and 2 main contacts NC, with no auxiliary contacts. Dimensions are 45 mm wide, 77 mm deep, and 86 mm high; net weight is 0.31 kg. The main circuit is rated 690 V, with control and main circuit rated frequency 50/60 Hz. Conventional free-air thermal current is 35 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 18 A at 415 V, 440 V, 380/400 V, and 220/230/240 V at 60 °C, and 10.5 A at 690 V at 60 °C. Rated operational power AC-3 is 7.5 kW at 400 V and 9 kW at 415 V, 440 V, 500 V, and 690 V. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, and CAN/CSA C22.2 No.60947-4-1.
- AF16Z-22-00-22
The ABB AF16Z-22-00-22 is a 4-pole AC contactor with 2 normally open and 2 normally closed main contacts, and no auxiliary contacts. It is rated 690 V in the main circuit and 6 kV impulse withstand voltage. AC-3 ratings include 18 A at 415 V and 10.5 A at 690 V, with rated operational power of 7.5 kW at 400 V. The control circuit accepts 48 to 130 V at 50 Hz, 60 Hz, or DC. Screw terminals accept main circuit conductors from 0.75 to 6 mm². It mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715, or on 2 x M4 screws placed diagonally. Dimensions are 45 mm width, 77 mm depth, and 86 mm height, with 0.31 kg net weight. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, CAN/CSA C22.2 No.60947-4-1.
- AF16Z-22-00-23
ABB AF16Z-22-00-23 AC contactor, 4-pole with 2 NO and 2 NC main contacts and no auxiliary contacts. Coil rated 100 to 250 V at 50 Hz, 100 to 250 V at 60 Hz, and 100 to 250 V DC. Main circuit rated operational voltage 690 V; rated operational current AC-1 30 A at 690 V and 40 °C; AC-3 18 A at 415 V and 60 °C. Rated operational power AC-3 7.5 kW at 400 V, 9 kW at 440 V. Rated insulation voltage 690 V per IEC 60947-4-1 and 600 V per UL/CSA; rated impulse withstand voltage 6 kV. Screw terminals, IP20 at main and coil terminals. Dimensions 45 mm wide, 77 mm deep, 86 mm high; net weight 0.31 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, CAN/CSA C22.2 No.60947-4-1.