- AF16Z-22-00-30
The ABB AF16Z-22-00-30 is a 4-pole IEC AC contactor with two normally open and two normally closed main contacts, and no auxiliary contacts. It is rated 690 V in the main circuit at 50/60 Hz, with AC-3 operational current of 18 A at 380/400 V and 60 °C, and AC-3 power of 7.5 kW at 380/400 V. The control circuit is rated 24 V DC. Terminals are screw type, with main and coil terminals rated IP20. It mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715, or on two diagonal M4 screws. Net dimensions are 45 mm wide, 97 mm deep, and 86 mm high; net weight is 0.43 kg. Standards include IEC/EN 60947-1 and IEC/EN 60947-4-1.
- AF16Z-22-00K-20
The ABB AF16Z-22-00K-20 is a 4-pole AC contactor with two normally open and two normally closed main contacts, and no auxiliary contacts. It measures 45 mm wide, 77 mm deep, and 92.3 mm high, and weighs 0.285 kg. The main circuit is rated 690 V at 50/60 Hz. Rated operational current AC-3 is 18 A at 380/400 V, 415 V, 440 V, and 220/230/240 V, and 10.5 A at 690 V, all at 60 °C. Rated operational power AC-3 is 7.5 kW at 400 V and 9 kW at 415 V, 440 V, 500 V, and 690 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 508, CSA C22.2 No. 60947-1-13, and CSA C22.2 No. 60947-4-1.
- AF16Z-22-00K-21
The ABB AF16Z-22-00K-21 is a 4-pole AC contactor with 2 main contacts NO and 2 main contacts NC, and no auxiliary contacts. It measures 45 mm wide, 77 mm deep, and 92.3 mm high, and weighs 0.285 kg. The main circuit is rated 690 V at 50/60 Hz. Rated operational current AC-3 is 18 A at 415 V and 440 V, 15 A at 500 V, and 10.5 A at 690 V, all at 60 °C. Rated operational power AC-3 is 7.5 kW at 400 V and 9 kW at 415 V, 440 V, 500 V, and 690 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 508, CSA C22.2 No. 60947-1-13, and CSA C22.2 No. 60947-4-1.
- AF16Z-22-00K-22
The ABB AF16Z-22-00K-22 is an AC contactor with two normally open and two normally closed main contacts, and no auxiliary contacts. Its main circuit is rated 690 V at 50/60 Hz. Per IEC 60947-4-1, conventional free-air thermal current is 35 A at 40 °C. Rated operational current AC-3 is 18 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, 15 A at 500 V, and 10.5 A at 690 V, all at 60 °C. Rated operational power AC-3 is 7.5 kW at 400 V, 9 kW at 415 V, 440 V, 500 V, and 690 V, and 4 kW at 220/230/240 V. Dimensions are 45 mm wide, 77 mm deep, and 92.3 mm high; weight is 0.285 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 508, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-4-1.
- AF16Z-22-00K-23
The ABB AF16Z-22-00K-23 is an AC contactor with two normally open and two normally closed main contacts, and no auxiliary contacts. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.285 kg. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 35 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 18 A at 415 V and 440 V, 15 A at 500 V, and 10.5 A at 690 V, all at 60 °C. Applicable standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 508, CSA C22.2 No. 60947-1-13, and CSA C22.2 No. 60947-4-1.
- AF16Z-30-01-20
The ABB AF16Z-30-01-20 is an AC contactor with three normally open main contacts and one normally closed auxiliary contact. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.31 kg. It is rated for a main and auxiliary circuit operational voltage of 690 V at 50/60 Hz. Rated operational current AC-3 is 18 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, 15 A at 500 V, and 10.5 A at 690 V, all at 60 °C. Rated operational power AC-3 is 7.5 kW at 400 V and 9 kW at 415 V, 440 V, 500 V, and 690 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AF16Z-30-01-21
ABB AF16Z-30-01-21 is an AC contactor with three normally open main contacts and one normally closed auxiliary contact. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.31 kg. The main and auxiliary circuits are rated 690 V, with a rated frequency of 50/60 Hz. Conventional free-air thermal current is 35 A per IEC 60947-4-1 at 40 °C, and 16 A per IEC 60947-5-1 at 40 °C. Rated operational current AC-3 is 18 A at 415 V and 10.5 A at 690 V, both at 60 °C. Rated operational power AC-3 is 7.5 kW at 400 V and 9 kW at 415 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1. Manufacturer ID 1SBL176001R2101.
- AF16Z-30-01-22
The ABB AF16Z-30-01-22 is an AC contactor with three main normally open contacts and one auxiliary normally closed contact. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.31 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 18 A at 415 V and 440 V, 15 A at 500 V, and 10.5 A at 690 V, all at 60 °C. Rated control circuit voltage is 48 to 130 V at 50 Hz, 60 Hz, and DC. It mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715, or on two M4 screws placed diagonally. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.