- OS1200L02
ABB OS1200L02 fuse protector, identified by manufacturer ID 1SCA116924R1001. It is a 2-pole, front-operated fuse switch disconnector for base mounting, with lug terminals 50 mm wide and tightening torque 50 to 75 N·m. Main circuit rated current is 1200 A; fuse size is 1200 A, Class L. Rated insulation voltage is 1000 V, rated impulse withstand voltage 12 kV, and rated operational voltage 600 V AC. Conventional free-air thermal current is 1250 A at 40 °C; fully enclosed conventional thermal current is 1000 A. Rated conditional short-circuit current is 80 kA at 690 V, and short-time withstand current is 40 kA rms for 1 s. Pollution degree 3. Dimensions are 426 mm H x 319 mm W x 294 mm D; net weight 21.4 kg. Standards: UL98, IEC 60947-3. Handle and shaft are not included.
- OS1200L04N2
ABB OS1200L04N2 fuse protector, identified by manufacturer ID 1SCA105331R1001. It is a four-pole, front-operated fuse switch disconnector for base mounting, with line terminals usable top-in/bottom-out or bottom-in/top-out. Main circuit rated current is 1200 A at 600 V AC; rated insulation voltage is 1000 V and rated impulse withstand voltage is 12 kV. Conventional free-air thermal current is 1250 A at 40 °C, and fully enclosed conventional thermal current is 1000 A. Fuse size is 1200 A, Class L. Rated conditional short-circuit current is 80 kA at 690 V; rated short-time withstand current is 40 kA rms for 1 s. Standards: UL98, IEC 60947-3. Handle and shaft are not included. Net dimensions: 539 mm width, 426 mm height, 294 mm depth; net weight 39.065 kg.
- OS1200L04N2P
ABB OS1200L04N2P fuse protector, manufacturer ID 1SCA105463R1001, is a four-pole fuse switch disconnector for base mounting with front operation and a pistol handle and shaft included. Main circuit rated current is 1200 A at 600 V AC; fuse size is 1200 A, Class L. Conventional free-air thermal current is 1250 A at 40 °C, and conventional thermal current fully enclosed is 1000 A. Rated insulation voltage is 1000 V, rated impulse withstand voltage is 12 kV, and rated conditional short-circuit current is 80 kA at 690 V. The fourth pole is switched with a solid link, right side. Dimensions are 539 mm width, 426 mm height, 294 mm depth; net weight 40.025 kg. Standards: UL98, IEC 60947-3.
- OS1200L12
The ABB OS1200L12 is a three-pole front-operated fuse switch disconnector for base mounting, with a 1200 A main-circuit rated current and Class L fuse size. Conventional free-air thermal current is 1250 A at 40 °C; fully enclosed conventional thermal current is 1000 A. Rated insulation voltage is 1000 V, rated impulse withstand voltage is 12 kV, and rated conditional short-circuit current is 80 kA at 690 V. It carries UL98 and IEC 60947-3. Terminals are lug type, 50 mm wide, with tightening torque 50 to 75 N·m. Dimensions are 432 mm wide, 426 mm high, and 294 mm deep; net weight is 31.23 kg. Handle and shaft are not included.
- OS1200L12P
ABB OS1200L12P fuse switch disconnector, 3-pole, front-operated, base mounting, with pistol handle and shaft included. Rated current 1200 A; conventional free-air thermal current 1250 A at 40 °C; fully enclosed thermal current 1000 A. Fuse system Class L, fuse size 1200 A. Rated insulation voltage 1000 V, rated impulse withstand voltage 12 kV, rated operational voltage 600 V AC. Rated conditional short-circuit current 80 kA at 690 V; rated short-time withstand current 40 kA rms for 1 s. Lug terminals, 50 mm terminal width, tightening torque 50 to 75 N·m. Pollution degree 3. Net dimensions 432 mm wide, 426 mm high, 294 mm deep; net weight 32.19 kg. Standards: UL98, IEC 60947-3.
- OS1200L30
ABB fuse protector, model OS1200L30, manufacturer ID 1SCA109345R1001. Three-pole, front-operated, base-mounting fuse switch disconnector for Class L fuses rated 1200 A. Rated current (In) main circuit 1200 A; rated operational voltage main circuit 600 V AC; rated insulation voltage (Ui) 1000 V; rated impulse withstand voltage (Uimp) 12 kV. Conventional free-air thermal current (Ith) 1250 A at 40 °C; conventional thermal current (Ithe) 1000 A fully enclosed. Rated conditional short-circuit current (Inc) 80 kA at 690 V; rated short-time withstand current (Icw) 40 kA rms for 1 s. Cable cross-section 2.5 to 25 mm²; lug terminals, 50 mm terminal width; tightening torque 50 to 75 N·m. Pollution degree 3. Dimensions 429 mm wide, 426 mm high, 294 mm deep; net weight 31.23 kg. Standards: UL98, IEC 60947-3. Handle and shaft not included.
- OS1250B02
The ABB OS1250B02 is a two-pole fuse protector with a rated current of 1250 A in the main circuit and a rated operational voltage of 690 V AC. It is a front-operated, base-mounting device with top or bottom line terminals, lug terminals 50 mm wide, and a tightening torque of 50 to 75 N·m. Conventional free-air thermal current is 1250 A at 40 °C; fully enclosed conventional thermal current is 1000 A. Rated conditional short-circuit current is 80 kA at 690 V, rated short-time withstand current is 40 kA rms for 1 s, rated impulse withstand voltage is 12 kV, and rated insulation voltage is 1000 V. It conforms to IEC 60947-3. Fuse size D1, British Standard fuse system. Handle and shaft are not included. Net dimensions are 294 mm wide, 319 mm high, and 356 mm deep; net weight is 19.8 kg.
- OS1250B03
The ABB OS1250B03 fuse protector is a front-operated, 3-pole fuse switch disconnector for base mounting. It uses British Standard D1 fuse size and accepts lug terminals with a 50 mm terminal width and tightening torque of 50 to 75 N·m. Rated current is 1250 A in the main circuit, with conventional free-air thermal current 1250 A at 40 °C and fully enclosed thermal current 1000 A. Rated operational voltage is 690 V AC; rated insulation voltage is 1000 V and rated impulse withstand voltage is 12 kV. Rated conditional short-circuit current is 80 kA at 690 V, and short-time withstand current is 40 kA rms for 1 s. Pollution degree is 3. Handle and shaft are not included. Dimensions are 429 mm width, 356 mm height, 294 mm depth; net weight 28.11 kg. Standards: IEC 60947-3.