- OS1250B02
The ABB OS1250B02 is a two-pole fuse protector with a rated current of 1250 A in the main circuit and a rated operational voltage of 690 V AC. It is a front-operated, base-mounting device with top or bottom line terminals, lug terminals 50 mm wide, and a tightening torque of 50 to 75 N·m. Conventional free-air thermal current is 1250 A at 40 °C; fully enclosed conventional thermal current is 1000 A. Rated conditional short-circuit current is 80 kA at 690 V, rated short-time withstand current is 40 kA rms for 1 s, rated impulse withstand voltage is 12 kV, and rated insulation voltage is 1000 V. It conforms to IEC 60947-3. Fuse size D1, British Standard fuse system. Handle and shaft are not included. Net dimensions are 294 mm wide, 319 mm high, and 356 mm deep; net weight is 19.8 kg.
- OS1250B03
The ABB OS1250B03 fuse protector is a front-operated, 3-pole fuse switch disconnector for base mounting. It uses British Standard D1 fuse size and accepts lug terminals with a 50 mm terminal width and tightening torque of 50 to 75 N·m. Rated current is 1250 A in the main circuit, with conventional free-air thermal current 1250 A at 40 °C and fully enclosed thermal current 1000 A. Rated operational voltage is 690 V AC; rated insulation voltage is 1000 V and rated impulse withstand voltage is 12 kV. Rated conditional short-circuit current is 80 kA at 690 V, and short-time withstand current is 40 kA rms for 1 s. Pollution degree is 3. Handle and shaft are not included. Dimensions are 429 mm width, 356 mm height, 294 mm depth; net weight 28.11 kg. Standards: IEC 60947-3.
- OS1250B03K
The ABB OS1250B03K is a three-pole fuse switch disconnector for base mounting with a direct-mounted, front-operated handle and a left-side operating mechanism (03). It is rated 1250 A in the main circuit and 1000 A fully enclosed, with a rated insulation voltage of 1000 V, a rated impulse withstand voltage of 12 kV, and pollution degree 3. Rated operational voltage is 690 V AC. Conventional free-air thermal current is 1250 A at 40 °C. Rated conditional short-circuit current is 80 kA at 690 V, and rated short-time withstand current is 40 kA rms for 1 s. It uses British Standard D1 fuses, lug terminals 50 mm wide, tightening torque 50 to 75 N·m, and complies with IEC 60947-3. Net dimensions are 429 mm wide, 356 mm high, and 294 mm deep; net weight is 45 kg.
- OS1250B03N3P
ABB OS1250B03N3P fuse switch disconnector, three-pole, base mounting, front operated. Rated current 1250 A; conventional free-air thermal current 1250 A at 40 °C; conventional thermal current 1000 A fully enclosed. Rated operational voltage 690 V AC, rated insulation voltage 1000 V, rated impulse withstand voltage 12 kV. Rated conditional short-circuit current 80 kA at 690 V; rated short-time withstand current 40 kA rms for 1 s. Fuse size D1, British Standard fuse system. Lug terminals, 50 mm terminal width, tightening torque 50 to 75 N·m. Fourth pole: detachable neutral link integrated into the mechanism. Pistol handle and shaft included. Pollution degree 3. Power loss 75 W per pole at rated operating conditions. Net dimensions 429 mm wide, 356 mm high, 366 mm deep; net weight 30.21 kg. Standards: IEC 60947-3.
- OS1250B03P
The ABB OS1250B03P is a three-pole fuse switch disconnector for base mounting, front operated, with a pistol handle and shaft included. It is rated 1250 A in the main circuit and 1000 A fully enclosed, with a rated operational voltage of 690 V AC. Conventional free-air thermal current is 1250 A at 40 °C. Rated insulation voltage is 1000 V, rated impulse withstand voltage is 12 kV, and rated conditional short-circuit current is 80 kA at 690 V. It accepts D1 fuses in the British Standard system and uses 50 mm lug terminals with 50 to 75 N·m tightening torque. It conforms to IEC 60947-3. Dimensions are 429 mm wide, 356 mm high, and 366 mm deep; net weight is 29.07 kg.
- OS1250B04F
ABB OS1250B04F is a four-pole fuse switch disconnector for base mounting, front operated, with the operating mechanism on the left side. Main circuit rated current is 1250 A at a rated operational voltage of 690 V AC; conventional free-air thermal current is 1250 A at 40 °C, and fully enclosed conventional thermal current is 1000 A. Rated insulation voltage is 1000 V, rated impulse withstand voltage is 12 kV, and rated conditional short-circuit current is 80 kA at 690 V. It uses British Standard D1 fuses; the fourth pole is switched-fusible. Lug terminals are 50 mm wide, tightening torque 50 to 75 N·m. Pollution degree 3. Dimensions are 294 mm wide, 539 mm high, 356 mm deep; net weight 36.5 kg. Standards: IEC 60947-3. Handle and shaft are not included.
- OS1250B22N2P
ABB OS1250B22N2P fuse switch disconnector, four-pole, front-operated, base mounting, with pistol handle and shaft included. Main circuit rated current 1250 A at 690 V AC; conventional free-air thermal current 1250 A at 40 °C; fully enclosed conventional thermal current 1000 A. Rated insulation voltage 1000 V, rated impulse withstand voltage 12 kV, rated conditional short-circuit current 80 kA at 690 V, and short-time withstand current 40 kA rms for 1 s. Power loss 75 W per pole at rated operating conditions. Fuse size D1, British Standard fuse system, lug terminals 50 mm wide, tightening torque 50 to 75 N·m. Pollution degree 3. Dimensions 542 mm wide, 356 mm high, 371 mm deep; net weight 36.705 kg. Standards: IEC 60947-3.
- OS1250D01
The ABB OS1250D01 fuse protector is a single-pole, front-operated fuse switch disconnector for base mounting. It accepts NH4 fuses in the DIN fuse system and uses lug terminals with a tightening torque of 50 to 75 N·m. The main circuit is rated 690 V AC, and power loss is 75 W per pole at rated operating conditions. Dimensions are 294 mm wide, 209 mm high, and 356 mm deep, with a net weight of 10.9 kg. It is classified under IEC 60947-3. The manufacturer identifier is 1SCA114036R1001. The legacy description references an OS1250D01P model, which conflicts with the authoritative display model OS1250D01 and is therefore omitted.