- OS1250B03P
The ABB OS1250B03P is a three-pole fuse switch disconnector for base mounting, front operated, with a pistol handle and shaft included. It is rated 1250 A in the main circuit and 1000 A fully enclosed, with a rated operational voltage of 690 V AC. Conventional free-air thermal current is 1250 A at 40 °C. Rated insulation voltage is 1000 V, rated impulse withstand voltage is 12 kV, and rated conditional short-circuit current is 80 kA at 690 V. It accepts D1 fuses in the British Standard system and uses 50 mm lug terminals with 50 to 75 N·m tightening torque. It conforms to IEC 60947-3. Dimensions are 429 mm wide, 356 mm high, and 366 mm deep; net weight is 29.07 kg.
- OS1250B04F
ABB OS1250B04F is a four-pole fuse switch disconnector for base mounting, front operated, with the operating mechanism on the left side. Main circuit rated current is 1250 A at a rated operational voltage of 690 V AC; conventional free-air thermal current is 1250 A at 40 °C, and fully enclosed conventional thermal current is 1000 A. Rated insulation voltage is 1000 V, rated impulse withstand voltage is 12 kV, and rated conditional short-circuit current is 80 kA at 690 V. It uses British Standard D1 fuses; the fourth pole is switched-fusible. Lug terminals are 50 mm wide, tightening torque 50 to 75 N·m. Pollution degree 3. Dimensions are 294 mm wide, 539 mm high, 356 mm deep; net weight 36.5 kg. Standards: IEC 60947-3. Handle and shaft are not included.
- OS1250B22N2P
ABB OS1250B22N2P fuse switch disconnector, four-pole, front-operated, base mounting, with pistol handle and shaft included. Main circuit rated current 1250 A at 690 V AC; conventional free-air thermal current 1250 A at 40 °C; fully enclosed conventional thermal current 1000 A. Rated insulation voltage 1000 V, rated impulse withstand voltage 12 kV, rated conditional short-circuit current 80 kA at 690 V, and short-time withstand current 40 kA rms for 1 s. Power loss 75 W per pole at rated operating conditions. Fuse size D1, British Standard fuse system, lug terminals 50 mm wide, tightening torque 50 to 75 N·m. Pollution degree 3. Dimensions 542 mm wide, 356 mm high, 371 mm deep; net weight 36.705 kg. Standards: IEC 60947-3.
- OS1250D01
The ABB OS1250D01 fuse protector is a single-pole, front-operated fuse switch disconnector for base mounting. It accepts NH4 fuses in the DIN fuse system and uses lug terminals with a tightening torque of 50 to 75 N·m. The main circuit is rated 690 V AC, and power loss is 75 W per pole at rated operating conditions. Dimensions are 294 mm wide, 209 mm high, and 356 mm deep, with a net weight of 10.9 kg. It is classified under IEC 60947-3. The manufacturer identifier is 1SCA114036R1001. The legacy description references an OS1250D01P model, which conflicts with the authoritative display model OS1250D01 and is therefore omitted.
- OS1250D01P
The ABB OS1250D01P is a single-pole fuse switch disconnector for base mounting, front operated, using NH4 size fuses in the DIN fuse system. It is rated for a main circuit operational voltage of 690 V AC and is designed per IEC 60947-3. Power loss is 75 W per pole at rated operating conditions. Connections are made via lug terminals with a tightening torque of 50 to 75 N·m. Dimensions are 294 mm wide, 209 mm high, and 356 mm deep, with a net weight of 11.9 kg. The manufacturer ID is 1SCA114035R1001. ETIM classification is EC001040. A WEEE category of 5 applies.
- OS1250D02
ABB OS1250D02 fuse protector, two-pole, base mounting, front operated, with the operating mechanism on the left side (02). It accepts NH4 DIN fuse systems and uses lug terminals 50 mm wide, tightened to 50 ... 75 N·m. Rated current is 1250 A in the main circuit; conventional free-air thermal current is 1250 A at θ = 40 °C, and conventional thermal current fully enclosed is 1000 A. Rated operational voltage is 690 V AC, rated insulation voltage 1000 V, rated impulse withstand voltage 12 kV, and rated conditional short-circuit current 80 kA at 690 V. Cable cross-section range is 2.5 ... 25 mm². Power loss is 75 W per pole at rated operating conditions. Standards: IEC 60947-3. Handle and shaft are not included.
- OS1250D03N3
ABB fuse protector, model OS1250D03N3, is a 3+N pole fuse switch disconnector for base mounting with front operation. Main circuit rated current is 1250 A at a rated operational voltage of 690 V AC; conventional free-air thermal current is 1250 A at 40 °C, and fully enclosed conventional thermal current is 1000 A. It accepts NH4 DIN fuses and lug terminals 50 mm wide, tightened to 50 ... 75 N·m. Rated insulation voltage is 1000 V, rated impulse withstand voltage 12 kV, rated conditional short-circuit current 80 kA at 690 V, and short-time withstand current 40 kA rms for 1 s. Pollution degree 3, IEC 60947-3. Dimensions 294 mm wide, 429 mm high, 356 mm deep; net weight 28.2 kg. Handle and shaft not included.
- OS1250D04F
ABB OS1250D04F is a four-pole fuse protector with a DIN fuse system for NH4 fuses. The fourth pole is a switched, fusible pole. Rated current of the main circuit is 1250 A, rated operational voltage 690 V AC, rated insulation voltage 1000 V, and rated impulse withstand voltage 12 kV. Conventional free-air thermal current is 1250 A at 40 °C; conventional thermal current in a fully enclosed arrangement is 1000 A. Rated conditional short-circuit current is 80 kA at 690 V, and rated short-time withstand current is 40 kA rms for 1 s. Power loss is 75 W per pole at rated operating conditions. It is front operated, base mounted, with lug terminals 50 mm wide and tightening torque 50 to 75 N·m. Standards: IEC 60947-3. Pollution degree 3. Handle and shaft are not included. Dimensions: 539 mm width, 356 mm height, 294 mm depth; net weight 34.875 kg.