- AX150-30-11-80
The ABB AX150-30-11-80 is a three-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It has a rated operational voltage of 1000 V for the main circuit and a rated frequency of 60 Hz. The conventional free-air thermal current is 190 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 190 A at 690 V and 40 °C, 145 A at 55 °C, and 130 A at 70 °C. AC-3 ratings include 150 A at 415 V and 55 °C, and 100 A at 440 V and 55 °C. Rated operational power AC-3 is 75 kW at 415 V and 45 kW at 220/230/240 V. Dimensions are 102 mm wide, 123.5 mm deep, and 148 mm high, with a net weight of 1.9 kg.
- AX150-30-11-81
The ABB AX150-30-11-81 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. The main circuit is rated 1000 V at 50 Hz. Conventional free-air thermal current is 190 A according to IEC 60947-4-1 at 40 °C. Rated operational current AC-3 is 150 A at 380/400 V, 415 V, and 220/230/240 V at 55 °C, and 82 A at 690 V at 55 °C. Rated operational power AC-3 is 75 kW at 415 V and 380/400 V. Dimensions are 102 mm wide, 123.5 mm deep, and 148 mm high, with a net weight of 1.9 kg. Main circuit terminals are bars; auxiliary terminals are IP40 according to IEC 60529.
- AX150-30-11-83
ABB AX150-30-11-83 AC contactor, manufacturer ID 1SFL991074R8311. Three normally open main contacts, one normally open and one normally closed auxiliary contact. Main circuit rated operational voltage 1000 V, rated frequency 60 Hz. Conventional free-air thermal current per IEC 60947-4-1, open contactors at 40 °C, is 190 A. Rated operational current AC-1 at 690 V: 190 A at 40 °C, 145 A at 55 °C, 130 A at 70 °C. Rated operational current AC-3 at 55 °C includes 150 A at 415 V and 150 A at 380/400 V. Rated operational power AC-3 at 415 V is 75 kW. Rated insulation voltage per IEC 60947-4-1 and VDE 0110 (Gr. C) is 690 V; rated impulse withstand voltage is 8 kV. Dimensions 102 mm wide, 123.5 mm deep, 148 mm high; net weight 1.9 kg.
- AX150-30-11-84
The ABB AX150-30-11-84 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 102 mm wide, 123.5 mm deep, and 148 mm high, and weighs 1.9 kg. The main circuit is rated 1000 V and 50 Hz. Conventional free-air thermal current is 190 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 150 A at 415 V and 55 °C, and rated operational power AC-3 is 75 kW at 415 V. Rated insulation voltage is 690 V according to IEC 60947-4-1 and VDE 0110 (Gr. C), with rated impulse withstand voltage 8 kV.
- AX150-30-11-85
ABB AX150-30-11-85 AC contactor, manufacturer ID 1SFL991074R8511. It has three normally open main contacts, no normally closed main contacts, and one normally open plus one normally closed auxiliary contact. Main circuit rated operational voltage is 1000 V at 60 Hz. Conventional free-air thermal current is 190 A according to IEC 60947-4-1 for open contactors at 40 °C. AC-1 rated operational current is 190 A at 690 V and 40 °C, 145 A at 55 °C, and 130 A at 70 °C. AC-3 ratings include 150 A at 415 V and 55 °C, and 75 kW at 415 V. Dimensions are 102 mm wide, 123.5 mm deep, and 148 mm high; net weight 1.9 kg.
- AX150-30-11-86
The ABB AX150-30-11-86 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 102 mm wide, 123.5 mm deep, and 148 mm high, and weighs 1.9 kg. The main circuit is rated 1000 V at 60 Hz. Conventional free-air thermal current is 190 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 150 A at 415 V and 55 °C, and rated operational power AC-3 is 75 kW at 415 V. Maximum electrical switching frequency is 300 cycles per hour. Manufacturer ID: 1SFL991074R8611.
- AX150-30-11-88
The ABB AX150-30-11-88 is an AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. Its main circuit is rated 1000 V and 60 Hz. Conventional free-air thermal current is 190 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 190 A at 690 V and 40 °C, 145 A at 55 °C, and 130 A at 70 °C. Rated operational current AC-3 at 55 °C includes 150 A at 415 V and 380/400 V, 100 A at 440 V and 500 V, and 82 A at 690 V. Dimensions are 102 mm wide, 123.5 mm deep, and 148 mm high; weight is 1.9 kg.
- AX18-30-01-26
The ABB AX18-30-01-26 is a block-type AC contactor with three normally open main contacts and one normally closed auxiliary contact. It is rated 690 V for both main and auxiliary circuits at 50/60 Hz, with a rated insulation voltage of 690 V and an impulse withstand voltage of 6 kV in the auxiliary circuit. AC-3 ratings include 18 A at 415 V and 380/400 V, and 9 A at 690 V, corresponding to 9 kW at 415 V and 7.5 kW at 380/400 V. Control circuit voltage is 105 V at 50 Hz and 110 to 127 V at 60 Hz. Dimensions are 44 mm wide, 74 mm deep and 74 mm high; weight is 0.326 kg. Screw terminals; coil terminals IP20.