Product Model
AX150-30-11-83
Material Number
1SFL991074R8311
Manufacturer
ABB
Product ID
91082

Get a Free Quote

Request pricing and availability for AX150-30-11-83.

More parts to source? Send your whole list in one enquiry

Key specifications

Product Net Weight
1.9 kg
Rated Operational Voltage
Main Circuit 1000 V
Rated Frequency (f)
Main Circuit 60 Hz
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 190 A (690 V) 55 °C 145 A (690 V) 70 °C 130 A
Rated Operational Power AC-3 (Pe)
(415 V) 75 kW (440 V) 59 kW (500 V) 59 kW (690 V) 75 kW (380 / 400 V) 75 kW (220 / 230 / 240 V) 45 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 800 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 160 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 350 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1320 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 500 A
See all specifications

Product Highlights

  1. Contact Configuration: 3 normally open main contacts, plus 1 normally open and 1 normally closed auxiliary contact
  2. Current and Power Ratings: AC-1 rated operational current 190 A at 40 °C and 130 A at 70 °C, AC-3 rated operational current 150 A at 380 to 415 V and 82 A at 690 V, with AC-3 motor power up to 75 kW
  3. Switching Capacity: AC-3 making capacity 10 x Ie and breaking capacity 8 x Ie, rated short-time withstand current 1320 A for 1 s, maximum electrical switching frequency 300 cycles per hour
  4. Coil and Voltage: rated control circuit voltage 48 V at 50 Hz and 60 Hz, rated operational voltage 1000 V for the main circuit, rated insulation voltage 690 V, rated impulse withstand voltage 8 kV
  5. Durability and Operating Conditions: mechanical durability 10 million operations, maximum mechanical switching frequency 3600 cycles per hour, ambient air temperature -40 to 70 °C without thermal overload relay and -25 to 55 °C with thermal overload relay, maximum operating altitude 3000 m without derating
  6. Dimensions and Protection: 102 mm wide, 123.5 mm deep, 148 mm high, 1.9 kg, main circuit bar terminals, auxiliary terminals IP40
AX150-30-11-83

Product Information

Technical Specifications

Specifications for AX150-30-11-83

ParameterValue
Product Net Width102 mm
Product Net Depth / Length123.5 mm
Product Net Height148 mm
Product Net Weight1.9 kg
Number of Main Contacts NO3
Number of Main Contacts NC0
Number of Auxiliary Contacts NO1
Number of Auxiliary Contacts NC1
Rated Operational VoltageMain Circuit 1000 V
Rated Frequency (f)Main Circuit 60 Hz
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 190 A
Rated Operational Current AC-1 (Ie)(690 V) 40 °C 190 A (690 V) 55 °C 145 A (690 V) 70 °C 130 A
Rated Operational Current AC-3 (Ie)(415 V) 55 °C 150 A (440 V) 55 °C 100 A (500 V) 55 °C 100 A (690 V) 55 °C 82 A (380400 V) 55 °C 150 A (220230240 V) 55 °C 150 A
Rated Operational Power AC-3 (Pe)(415 V) 75 kW (440 V) 59 kW (500 V) 59 kW (690 V) 75 kW (380400 V) 75 kW (220230240 V) 45 kW
Rated Breaking Capacity AC-38 x Ie AC-3
Rated Making Capacity AC-310 x Ie AC-3
ParameterValue
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 800 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 160 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 350 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1320 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 500 A
Maximum Electrical Switching Frequency300 cycles per hour
Rated Insulation Voltage (Ui)acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (Uimp)8 kV
Mechanical Durability10 million
Maximum Mechanical Switching Frequency3600 cycles per hour
Coil Operating Limits(acc. to IEC 60947-4-1) Uc (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)50 Hz 48 V 60 Hz 48 V
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP40
Terminal TypeMain Circuit: Bars
Ambient Air TemperatureClose to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 55 °C Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C Close to Contactor for Storage -40 ... 70 °C
Maximum Operating Altitude PermissibleWithout Derating 3000 m
Object Classification CodeQ
ETIM 7EC000066 - Power contactor, AC switching
ETIM 8EC000066 - Power contactor, AC switching
ETIM 9EC000066 - Power contactor, AC switching
eClassV11.0 : 27371003
UNSPSC39121529
IDEA Granular Category Code (IGCC)4755 >> Contactors
Manufacturer ID1SFL991074R8311