- OT400E01
ABB OT400E01 is a single-pole isolating switch with base mounting and front operation. Its conventional free-air thermal current (Ith) is 400 A at an ambient temperature of 40 °C, and its conventional thermal current for a fully enclosed installation (Ithe) is 400 A. Power loss is 10 W per pole at rated operating conditions. The switch has a front degree of protection of IP00 and pollution degree 3. Mechanical durability is 16000 operations. Dimensions are 103 mm wide, 185 mm high, and 107 mm deep; net weight is 1.4 kg (3.1 lb). Line terminals may be connected top in - bottom out or bottom in - top out. A handle and shaft are not included, and no lock is provided. Manufacturer ID: 1SCA022765R8170.
- OT400E01P
The ABB OT400E01P is a base-mounting switch disconnector with one pole and front operation. It is rated 400 A at 40 °C conventional free-air thermal current and 400 A fully enclosed. Rated operational current is 400 A at 380–415 V, 500 V, 690 V, and 1000 V for AC-21A, AC-22A, and AC-23A. Rated operational power AC-23A is 132 kW at 220–240 V, 230 kW at 400–415 V, 280 kW at 500 V, and 400 kW at 690 V. Rated insulation voltage is 1000 V per IEC/EN 60664-1, rated impulse withstand voltage is 12 kV, and rated short-time withstand current is 15 kA for 1 s. It conforms to IEC 60947-3. Dimensions are 103 mm wide, 185 mm high, and 107 mm deep, weighing 1.8 kg.
- OT400E02K
ABB OT400E02K is listed in the Isolating switch category. Key specifications include Degree of Protection: Front IP00, Environmental Information: 1SCC301266D0201, Pollution Degree: 3, and Product Net Width: 147 mm. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- OT400E03
The ABB OT400E03 is a front-operated, 3-pole isolating switch with a 400 A rating and a rated insulation voltage of 1000 V according to IEC/EN 60664-1. It is base mounted and uses lug terminals. The conventional free-air thermal current is 400 A at 40 °C, and the fully enclosed conventional thermal current is 400 A. Rated operational current is 400 A at 380 to 415 V, 500 V, and 690 V for AC-21A, AC-22A, and AC-23A. Rated impulse withstand voltage is 12 kV, rated short-time withstand current is 15 kA for 1 s, and rated short-circuit making capacity is 65 kA at 690 V. The switch conforms to IEC 60947-3. Dimensions are 191 mm width, 185 mm height, and 107 mm depth, with 2.8 kg net weight. Front degree of protection is IP00. Handle and shaft are not included.
- OT400E03C
The ABB OT400E03C is a 3-pole, front-operated isolating switch intended for base mounting. It is rated 400 A conventional free-air thermal current at 40 °C and 400 A conventional thermal current fully enclosed. Rated impulse withstand voltage is 12 kV, with pollution degree 3 and front degree of protection IP20. Line terminals may be connected top in - bottom out or bottom in - top out. Power loss is 10 W per pole at rated operating conditions. Dimensions are 221 mm width, 185 mm height, and 203 mm depth; net weight is 5.68 kg. The handle and shaft are not included and must be ordered separately. Manufacturer ID: 1SCA022764R1950.
- OT400E03CFP
ABB OT400E03CFP is a 3-pole, front-operated isolating switch intended for base mounting. The handle and shaft are included; the handle color is black. The switch is rated for a conventional free-air thermal current (Ith) of 400 A at an ambient temperature of 40 °C, and a conventional thermal current (Ithe) of 400 A when fully enclosed. Rated impulse withstand voltage (Uimp) is 12 kV, with pollution degree 3. Power loss is 10 W per pole at rated operating conditions. Line terminals can be configured top in - bottom out or bottom in - top out. Dimensions are 221 mm wide, 185 mm high, and 203 mm deep; net weight is 6.165 kg. Front degree of protection is IP20. Manufacturer ID: 1SCA106360R1001.
- OT400E03CK-104
ABB OT400E03CK-104 is an isolating switch. Manufacturer ID: 1SCA100164R1001. The device is intended for dual-power switching arrangements. It is designed for continuous operation in switching sequences. No electrical ratings, mechanical specifications, or standards are stated for this model.
- OT400E03CL
ABB OT400E03CL isolating switch, 3-pole, base mounting, front operated. Rated insulation voltage 1000 V, rated impulse withstand voltage 12 kV, rated operational voltage main circuit 1000 V. Conventional free-air thermal current 400 A at 40 °C; conventional thermal current fully enclosed 400 A. Rated operational current AC-21A, AC-22A, and AC-23A: 400 A at 380 to 415 V, 500 V, and 690 V. Rated operational power AC-23A: 220 kW at 380 to 415 V, 280 kW at 500 V, 400 kW at 690 V. Rated short-time withstand current 15 kA rms for 1 s. Front degree of protection IP20; pollution degree 3. Screw terminals, tightening torque 30 to 44 N·m according to IEC 60947-1. Power loss 10 W per pole at rated operating conditions. Handle and shaft not included. Net dimensions 221 x 185 x 203 mm; net weight 5.66 kg.