- OT400E03CLP
ABB OT400E03CLP is a 3-pole base-mounting isolating switch, front operated, with a black handle and shaft included. Its conventional free-air thermal current (Ith) is 400 A at an ambient temperature of 40 °C, and the conventional thermal current for the fully enclosed case (Ithe) is 400 A. Rated impulse withstand voltage (Uimp) is 12 kV, with pollution degree 3. Power loss is 10 W per pole at rated operating conditions. Line terminals may be configured top in - bottom out or bottom in - top out. Dimensions are 221 mm wide, 185 mm high, and 203 mm deep; net weight is 6 kg. Degree of protection at the front is IP20. Manufacturer ID: 1SCA108641R1001.
- OT400E03CP
The ABB OT400E03CP is a 3-pole, front-operated isolating switch intended for base mounting. It is supplied with a black handle and shaft. The switch has a rated conventional free-air thermal current (Ith) of 400 A at 40 °C and a conventional thermal current (Ithe) of 400 A fully enclosed. Rated impulse withstand voltage (Uimp) is 12 kV. Power loss is 10 W per pole at rated operating conditions. The front degree of protection is IP20, and the pollution degree is 3. Line terminals can be configured top in - bottom out or bottom in - top out. Net dimensions are 221 mm width, 185 mm height, and 203 mm depth; net weight is 6 kg. Manufacturer ID: 1SCA022771R8500.
- OT400E03CP-104
The ABB OT400E03CP-104 is an isolating switch supplied as a 400 A, 3-pole manual change-over switch. It is fitted with a black plastic IP65 I-0-II pistol handle, plus a shaft and bolt set for cable connection. The manufacturer ID for this item is 1SCA022835R1650. The IP65 rating applies to the handle as stated. No further electrical, mechanical, or performance ratings, standards, certifications, or applications are provided in the supplied data, so none are stated here. Verify configuration and suitability against the requirements of the intended installation before ordering.
- OT400E03DP
The ABB OT400E03DP is a front-operated isolating switch with six poles, supplied with a handle and shaft. It is rated for a conventional free-air thermal current (Ith) of 400 A at 40 °C and a fully enclosed thermal current (Ithe) of 400 A. Rated operational current is 400 A at 380–415 V, 500 V, and 690 V for AC-21A, AC-22A, and AC-23A. Rated insulation voltage is 1000 V according to IEC 60947-3, with a 12 kV impulse withstand voltage. Dimensions are 221 mm wide, 185 mm high, and 202.5 mm deep; net weight is 6.1 kg. Terminals are lug type, 25 mm wide, tightened to 30–44 N·m per IEC 60947-1. Front degree of protection is IP00.
- OT400E03K
ABB OT400E03K is listed in the Isolating switch category. Key specifications include Degree of Protection: Front IP00, Environmental Information: 1SCC301266D0201, Pollution Degree: 3, and Product Net Width: 191 mm. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- OT400E03P
The ABB OT400E03P is a 3-pole, front-operated isolating switch, base mounting, with the operating mechanism at the end of the switch on the left side. It is rated 400 A at 380 to 415 V, 500 V, and 690 V for AC-21A, AC-22A, and AC-23A. Rated operational power AC-23A is 132 kW at 220 to 240 V, 230 kW at 400 to 415 V, 280 kW at 500 V, and 400 kW at 690 V. Rated insulation voltage is 1000 V per IEC/EN 60664-1, rated impulse withstand voltage is 12 kV, and rated short-time withstand current Icw is 15 kA for 1 s. It uses lug terminals 25 mm wide with tightening torque 30 to 44 N·m per IEC 60947-1. Standards: IEC 60947-3. Dimensions 191 mm by 185 mm by 107 mm; net weight 3.2 kg.
- OT400E03P61
The ABB OT400E03P61 is a 3-pole isolating switch with lug terminals and a front-operated handle and shaft included. It is rated 400 A conventional thermal current (fully enclosed) and 1000 V rated insulation voltage according to IEC/EN 60664-1, with a 12 kV rated impulse withstand voltage. Rated operational current is 400 A at 380 to 415 V, 500 V, and 690 V for AC-21A, AC-22A, and AC-23A. Rated operational power AC-23A is 132 kW at 220 to 240 V, 230 kW at 400 to 415 V, 280 kW at 500 V, and 400 kW at 690 V. Short-circuit making capacity is 65 kA at 690 V; short-time withstand current is 15 kA for 1 s. It conforms to IEC 60947-3, has front IP00 protection, pollution degree 3, and 16000 mechanical operations. Dimensions are 191 mm width, 185 mm height, 107 mm depth, 3.2 kg.
- OT400E03W
ABB OT400E03W is a 3-pole base-mounting switch disconnector. It is front operated with the mechanism at the end of the switch, left side. Rated insulation voltage is 1000 V according to IEC/EN 60664-1; rated impulse withstand voltage is 12 kV. Conventional free-air thermal current Ith is 400 A at 40 °C, and conventional thermal current Ithe is 400 A fully enclosed. Rated operational current is 400 A at 380 to 415 V, 500 V, and 690 V for AC-21A, AC-22A, and AC-23A. Rated operational power AC-23A is 132 kW at 220 to 240 V, 230 kW at 400 to 415 V, 280 kW at 500 V, and 400 kW at 690 V. It conforms to IEC 60947-3. Front degree of protection is IP00. Dimensions are 221 mm wide, 185 mm high, and 107 mm deep; net weight is 3 kg. Handle and shaft are not included.