- VB7-30-01-P-80
The ABB VB7-30-01-P-80 is a 3-pole invertible contactor with three normally open main contacts and one normally closed auxiliary contact. It measures 96.2 mm wide, 57.5 mm high, and 47.7 mm deep, weighs 0.345 kg, and mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715. The main circuit is rated 690 V AC, 6 kV impulse withstand, and 12 A AC-1 at 220/240 V and 380/440 V, 6 A at 690 V. AC-3 rated power is 3 kW at 230 V and 5.5 kW at 400 V and 500 V, three phase. The coil is 220 to 240 V AC. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1, IEC 60335-2-40 A2L.
- VB7-30-01-P-84
The ABB VB7-30-01-P-84 is a 3-pole invertible contactor with three normally open main contacts and one normally closed auxiliary contact. It is rated 690 V AC in the main circuit and 110 to 127 V AC at the coil, with a rated impulse withstand voltage of 6 kV and a rated insulation voltage of 690 V. Rated operational power in AC-3 is 5.5 kW at 400 V and 500 V three-phase, and 3 kW at 230 V and 690 V three-phase. Mechanical durability is 10,000,000 cycles. Dimensions are 96.2 mm wide, 57.5 mm high, and 47.7 mm deep; net weight is 0.345 kg. It mounts on TH35-15 or TH35-7.5 DIN rail to IEC 60715.
- VB7-30-01-P-85
ABB invertible contactor VB7-30-01-P-85, manufacturer ID GJL1311909R8015. Three-pole device with three main NO contacts, no main NC contacts, and one auxiliary NC contact. Rated operational voltage is 690 V AC or 250 V DC for both main and auxiliary circuits; rated frequency is 50 Hz or 60 Hz for the main circuit, with DC also listed. Rated operational power AC-3 is 3 kW at 230 V three-phase, 5.5 kW at 400 V and 500 V three-phase, and 3 kW at 690 V three-phase. Rated control circuit voltage is 380 to 415 V AC, with coil operating limits of 0.85 to 1.1 x Uc per IEC 60947-4-1 at ambient temperatures up to 55 °C. Dimensions are 96.2 mm width, 57.5 mm height, and 47.7 mm depth; net weight 0.345 kg. Main circuit terminals are IP20.
- VB7-30-10-01
The ABB VB7-30-10-01 is a 3-pole invertible contactor with three normally open main contacts and one normally open auxiliary contact. It measures 96.2 mm wide, 57.5 mm high, and 46.7 mm deep, and weighs 0.355 kg. The main circuit is rated 690 V AC and 220 V DC, with a rated impulse withstand voltage of 6 kV and rated insulation voltage of 690 V. Rated operational current AC-1 is 20 A at 40 °C for 220/240 V and 380/440 V, and 6 A at 690 V. Rated operational power AC-3 is 3 kW at 230 V, 5.5 kW at 400 V and 500 V, and 3 kW at 690 V. The coil operates at 24 V AC. Mechanical durability is 10,000,000 cycles. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1, and IEC 60335-2-40 A2L.
- VB7-30-10-02
The ABB VB7-30-10-02 is an invertible contactor with three main contacts (NO) and one auxiliary contact (NO). Its rated control circuit voltage is 42 V AC, with coil operating limits of 0.85 to 1.1 x Uc at ambient temperatures up to 55 °C. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V, and 6 A at 690 V. Rated operational power AC-3 is 3 kW at 230 V, 5.5 kW at 400 V and 500 V, and 3 kW at 690 V. Mechanical durability is 10,000,000 cycles. Dimensions are 96.2 mm width, 57.5 mm height, and 46.7 mm depth, with a net weight of 0.355 kg. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, and UL 60947-4-1.
- VB7-30-10-03
The ABB VB7-30-10-03 is a 3-pole invertible contactor with three normally open main contacts and one normally open auxiliary contact. Its 48 V AC control coil operates within 0.85 to 1.1 times Uc at ambient temperatures up to 55 °C per IEC 60947-4-1. Main circuit ratings include 690 V AC operational voltage, 6 kV impulse withstand, and AC-3 power of 3 kW at 230 V and 5.5 kW at 400 V or 500 V. Dimensions are 96.2 mm wide, 57.5 mm high, and 46.7 mm deep, weighing 0.355 kg. It mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715 and carries IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, and UL 60947-4-1 designations.
- VB7-30-10-84
ABB VB7-30-10-84 invertible contactor with manufacturer ID GJL1311901R8104. It has 3 main poles, 3 NO main contacts, 0 NC main contacts, and 1 NO auxiliary contact. Rated control circuit voltage is 110 to 127 V AC. Main circuit rated operational voltage is 690 V AC, with rated frequency 50 Hz, 60 Hz, or DC. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V, and 6 A at 40 °C and 55 °C for 690 V. Rated operational power AC-3 is 3 kW at 230 V, 5.5 kW at 400 V and 500 V, and 3 kW at 690 V. Dimensions are 96.2 mm width, 57.5 mm height, and 46.7 mm depth; net weight is 0.355 kg.
- VB7-30-10-85
The ABB VB7-30-10-85 is an invertible contactor with three main NO contacts and one auxiliary NO contact. It measures 96.2 mm wide, 57.5 mm high, and 46.7 mm deep, and weighs 0.355 kg. The main circuit is rated 690 V AC and 220 V DC, with a rated impulse withstand voltage of 6 kV and rated insulation voltage of 690 V. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V, and 6 A at 690 V for both temperatures. Rated operational power AC-3 is 3 kW at 230 V, 5.5 kW at 400 V and 500 V, and 3 kW at 690 V three-phase. The control circuit voltage is 380 to 415 V AC. Mechanical durability is 10,000,000 cycles.