- VB7-30-10-84
ABB VB7-30-10-84 invertible contactor with manufacturer ID GJL1311901R8104. It has 3 main poles, 3 NO main contacts, 0 NC main contacts, and 1 NO auxiliary contact. Rated control circuit voltage is 110 to 127 V AC. Main circuit rated operational voltage is 690 V AC, with rated frequency 50 Hz, 60 Hz, or DC. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V, and 6 A at 40 °C and 55 °C for 690 V. Rated operational power AC-3 is 3 kW at 230 V, 5.5 kW at 400 V and 500 V, and 3 kW at 690 V. Dimensions are 96.2 mm width, 57.5 mm height, and 46.7 mm depth; net weight is 0.355 kg.
- VB7-30-10-85
The ABB VB7-30-10-85 is an invertible contactor with three main NO contacts and one auxiliary NO contact. It measures 96.2 mm wide, 57.5 mm high, and 46.7 mm deep, and weighs 0.355 kg. The main circuit is rated 690 V AC and 220 V DC, with a rated impulse withstand voltage of 6 kV and rated insulation voltage of 690 V. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V, and 6 A at 690 V for both temperatures. Rated operational power AC-3 is 3 kW at 230 V, 5.5 kW at 400 V and 500 V, and 3 kW at 690 V three-phase. The control circuit voltage is 380 to 415 V AC. Mechanical durability is 10,000,000 cycles.
- VB7-30-10-F-01
ABB invertible contactor VB7-30-10-F-01, manufacturer ID GJL1311903R0101. Three-pole device with three NO main contacts and one NO auxiliary contact. Rated operational voltage: main circuit 690 V AC / 220 V DC; auxiliary circuit 690 V AC / 250 V DC. Rated operational power AC-3: 3 kW at 230 V three-phase, 5.5 kW at 400 V and 500 V three-phase, 3 kW at 690 V three-phase. Rated control circuit voltage 24 V AC; coil operating limits 0.85 to 1.1 x Uc at ambient temperature up to 55 °C per IEC 60947-4-1. Dimensions 96.2 x 57.5 x 46.7 mm, net weight 0.345 kg. DIN-rail mounting per IEC 60715. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1, IEC 60335-2-40 A2L.
- VB7-30-10-F-80
ABB VB7-30-10-F-80 invertible contactor, manufacturer ID GJL1311903R8100. Three-pole contactor with three NO main contacts and one NO auxiliary contact. Rated operational power AC-3: 3 kW at 230 V three-phase, 5.5 kW at 400 V and 500 V three-phase, and 3 kW at 690 V three-phase. Rated operational current AC-1: 20 A at 220/240 V and 380/440 V at 40 °C, 16 A at those voltages at 55 °C, and 6 A at 690 V at 40 °C and 55 °C. Control circuit voltage 220 to 240 V AC; coil operating limits 0.85 to 1.1 x Uc at up to 55 °C per IEC 60947-4-1. Dimensions 96.2 x 57.5 x 46.7 mm, 0.345 kg. DIN-rail mounting per IEC 60715. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1, IEC 60335-2-40 A2L.
- VB7-30-10-P-01
ABB VB7-30-10-P-01 invertible contactor, manufacturer ID GJL1311909R0101. Three-pole device with three main NO contacts, no main NC contacts, and one auxiliary NO contact. Rated operational current AC-1 is 12 A at 220/240 V and 380/440 V, and 6 A at 690 V, at both 40 °C and 55 °C. Rated operational power AC-3 is 3 kW at 230 V, 5.5 kW at 400 V and 500 V, and 3 kW at 690 V, three-phase. Control circuit voltage is 24 V AC; coil operating limits per IEC 60947-4-1 are 0.85 to 1.1 x Uc at up to 55 °C. Mechanical durability is 10,000,000 cycles. Dimensions are 96.2 mm width, 57.5 mm height, 47.7 mm depth; net weight 0.345 kg. Main circuit terminals are IP20.
- VB7-30-10-P-03
ABB invertible contactor VB7-30-10-P-03 (manufacturer ID GJL1311909R0103) is a 3-pole device with three main contacts NO, no main contacts NC, and one auxiliary contact NO. Rated operational voltage is 690 V AC for main and auxiliary circuits, 220 V DC main, and 250 V DC auxiliary. Rated operational current AC-1 is 12 A at 220/240 V and 380/440 V, and 6 A at 690 V. Rated operational power AC-3 is 3 kW at 230 V and 5.5 kW at 400 V and 500 V, three-phase. Control circuit voltage is 48 V AC. It mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715, with dimensions 96.2 x 57.5 x 47.7 mm and weight 0.345 kg. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, and UL 60947-4-1.
- VB7-30-10-P-84
ABB invertible contactor VB7-30-10-P-84, manufacturer ID GJL1311909R8104. Three-pole device with three normally open main contacts and one normally open auxiliary contact. Rated control circuit voltage is 110 to 127 V AC; coil operating limits per IEC 60947-4-1 for AC supply are 0.85 to 1.1 x Uc at ambient temperature up to 55 °C. Rated operational power AC-3 is 3 kW at 230 V three-phase, 5.5 kW at 400 V three-phase, 5.5 kW at 500 V three-phase, and 3 kW at 690 V three-phase. Rated insulation voltage is 690 V according to UL/CSA and 600 V. Rated impulse withstand voltage for the main circuit is 6 kV. Dimensions are 96.2 mm width, 57.5 mm height, and 47.7 mm depth; net weight 0.345 kg. Mechanical durability is 10,000,000 cycles. Main circuit terminals have IP20 protection. DIN rail mounting per IEC 60715.
- VB7-30-10-P-85
ABB invertible contactor VB7-30-10-P-85, manufacturer ID GJL1311909R8105. Three-pole device with three NO main contacts and one NO auxiliary contact. Rated control circuit voltage 380 to 415 V AC; coil operating limits per IEC 60947-4-1 are 0.85 to 1.1 x Uc at ambient temperature up to 55 °C. Rated operational current AC-1 is 12 A at 220/240 V and 380/440 V, and 6 A at 690 V. Rated operational power AC-3 is 3 kW at 230 V, 5.5 kW at 400 V and 500 V, and 3 kW at 690 V, three-phase. Dimensions 96.2 x 57.5 x 47.7 mm, net weight 0.345 kg. Screw terminals, main circuit terminals IP20, DIN rail mounting per IEC 60715. Mechanical durability 10,000,000 cycles.