- VB7-30-10-P-85
ABB invertible contactor VB7-30-10-P-85, manufacturer ID GJL1311909R8105. Three-pole device with three NO main contacts and one NO auxiliary contact. Rated control circuit voltage 380 to 415 V AC; coil operating limits per IEC 60947-4-1 are 0.85 to 1.1 x Uc at ambient temperature up to 55 °C. Rated operational current AC-1 is 12 A at 220/240 V and 380/440 V, and 6 A at 690 V. Rated operational power AC-3 is 3 kW at 230 V, 5.5 kW at 400 V and 500 V, and 3 kW at 690 V, three-phase. Dimensions 96.2 x 57.5 x 47.7 mm, net weight 0.345 kg. Screw terminals, main circuit terminals IP20, DIN rail mounting per IEC 60715. Mechanical durability 10,000,000 cycles.
- VB7-40-00-01
ABB VB7-40-00-01 invertible contactor with manufacturer ID GJL1311901R0001. It has 4 main contacts, all normally open, and no auxiliary contacts. The rated control circuit voltage is 24 V AC, with coil operating limits of 0.85 to 1.1 times Uc at ambient temperatures up to 55 °C according to IEC 60947-4-1. Main circuit rated operational voltage is 690 V AC and 220 V DC, with rated insulation voltage 690 V and rated impulse withstand voltage 6 kV. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V, and 6 A at 690 V. Rated operational power AC-3 is 3 kW at 230 V, 5.5 kW at 400 V and 500 V, and 3 kW at 690 V. Dimensions are 96.2 mm width, 57.5 mm height, 46.7 mm depth; net weight 0.355 kg. Main circuit terminals are IP20.
- VB7-40-00-02
The ABB VB7-40-00-02 is a 4-pole invertible contactor with four normally open main contacts and no normally closed main or auxiliary contacts. It measures 96.2 mm wide, 57.5 mm high, and 46.7 mm deep, and weighs 0.355 kg. The main circuit is rated 690 V AC and 220 V DC, with a rated impulse withstand voltage of 6 kV and rated insulation voltage of 690 V according to UL/CSA and 600 V. The control circuit voltage is 42 V AC. Rated operational power AC-3 is 3 kW at 230 V, 5.5 kW at 400 V and 500 V, and 3 kW at 690 V for three-phase NO. Mechanical durability is 10,000,000 cycles. Main circuit terminals have IP20 protection. Mounting is on TH35-15 or TH35-7.5 DIN rail according to IEC 60715.
- VB7-40-00-03
ABB invertible contactor VB7-40-00-03, manufacturer ID GJL1311901R0003. Four-pole device with four normally open main contacts and no normally closed main or auxiliary contacts. Rated operational voltage is 690 V AC and 220 V DC for the main circuit; rated insulation voltage is 690 V, and rated impulse withstand voltage is 6 kV. Control circuit voltage is 48 V AC. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V, and 6 A at 690 V for both temperatures. Rated operational power AC-3 is 3 kW at 230 V, 5.5 kW at 400 V and 500 V, and 3 kW at 690 V three-phase. Mechanical durability is 10,000,000 cycles. Dimensions are 96.2 mm width, 57.5 mm height, and 46.7 mm depth; net weight 0.355 kg.
- VB7-40-00-80
The ABB VB7-40-00-80 is a four-pole invertible contactor with four NO main contacts and no auxiliary contacts. It measures 96.2 mm wide, 57.5 mm high, and 46.7 mm deep, and weighs 0.355 kg. The main circuit is rated 690 V AC and 220 V DC, with a rated impulse withstand voltage of 6 kV and rated insulation voltage of 690 V. AC-3 rated operational power is 3 kW at 230 V and 5.5 kW at 400 V and 500 V, three-phase. The control circuit voltage is 220 to 240 V AC. Mechanical durability is 10,000,000 cycles. Main circuit terminals are IP20. It mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, and UL 60947-4-1.
- VB7-40-00-84
The ABB VB7-40-00-84 is an invertible contactor with four poles and four normally open main contacts, no normally closed main contacts, and no auxiliary contacts. The main circuit is rated 690 V AC and 220 V DC, at 50 Hz, 60 Hz, or DC, with a rated impulse withstand voltage of 6 kV and rated insulation voltage of 690 V according to UL/CSA and 600 V. Rated operational current AC-1 is 20 A at 220/240 V and 380/440 V at 40 °C, 16 A at 55 °C, and 6 A at 690 V. Rated operational power AC-3 is 3 kW at 230 V three-phase, 5.5 kW at 400 V and 500 V three-phase, and 3 kW at 690 V three-phase. The control circuit voltage is 110 to 127 V AC. Dimensions are 96.2 mm wide, 57.5 mm high, and 46.7 mm deep, weighing 0.355 kg.
- VB705
ABB VB705 is an industrial catalog item. Key specifications include Product Type: Module_Termination_Unit, Product Net Depth / Length: 180 mm, Product Net Height: 80 mm, and Product Net Width: 160 mm. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- VB705A
ABB VB705A is an industrial catalog item. Key specifications include Medium Description: Vertical column mounting base for non-redundant SPC600A, SPC700A and SPC800A con, Product Type: Module_Termination_Unit, Product Net Depth / Length: 180 mm, and Product Net Height: 80 mm. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.