- AX80-30-00-36
The ABB AX80-30-00-36 is an AC contactor with three normally open main contacts and no auxiliary contacts. It has a rated operational voltage of 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 80 A at 380/400 V, 415 V, and 220/230/240 V, 70 A at 440 V, 65 A at 500 V, and 46 A at 690 V, all at 55 °C. Rated operational power AC-3 is 37 kW at 380/400 V, 40 kW at 415 V, 440 V, and 690 V, 45 kW at 500 V, and 22 kW at 220/230/240 V. Conventional free-air thermal current is 125 A per IEC 60947-4-1 at 40 °C. Dimensions are 70 mm wide, 110 mm deep, and 108 mm high, weighing 1.01 kg. Screw terminals; main terminals IP10, coil terminals IP20.
- AX80-30-00-75
The ABB AX80-30-00-75 is an AC contactor with three normally open main contacts and no auxiliary contacts. Its control circuit operates at 24 V, 50/60 Hz. Rated operational voltage is 690 V for both main and auxiliary circuits. Conventional free-air thermal current is 125 A at 40 °C per IEC 60947-4-1 for open contactors. AC-3 ratings include 80 A at 380/400 V and 415 V, 70 A at 440 V, 65 A at 500 V, and 46 A at 690 V, all at 55 °C. Rated insulation voltage is 690 V per IEC 60947-4-1 and VDE 0110 (Gr. C). Dimensions are 82 mm wide, 110 mm deep, and 108 mm high; net weight is 1.05 kg.
- AX80-30-00-80
The ABB AX80-30-00-80 is a block-type AC contactor with three normally open main contacts and no auxiliary contacts. The main and auxiliary circuits are rated 690 V at 50/60 Hz. Conventional free-air thermal current is 125 A per IEC 60947-4-1 at 40 °C. Rated operational current AC-3 is 80 A at 415 V and 55 °C, and rated operational power AC-3 is 40 kW at 415 V. The control circuit is rated 220 to 230 V at 50 Hz and 230 to 240 V at 60 Hz. Dimensions are 70 mm wide, 110 mm deep, and 108 mm high; weight is 1.01 kg. Terminals are screw type, with main terminals IP10 and coil terminals IP20 per IEC 60529.
- AX80-30-00-81
The ABB AX80-30-00-81 is an AC contactor with three main poles, normally open (NO), and no auxiliary contacts. Its main and auxiliary circuits are rated 690 V at 50/60 Hz. Rated operational current AC-3 (Ie) is 80 A at 380/400 V, 415 V, and 220/230/240 V, all at 55 °C; 70 A at 440 V; 65 A at 500 V; and 46 A at 690 V. Rated operational power AC-3 (Pe) is 37 kW at 380/400 V, 40 kW at 415 V, 440 V, and 690 V, 45 kW at 500 V, and 22 kW at 220/230/240 V. Conventional free-air thermal current (Ith) is 125 A per IEC 60947-4-1 at 40 °C. Control circuit voltage (Uc) is 24 V at 50 Hz and 60 Hz. Dimensions are 70 mm wide, 110 mm deep, and 108 mm high; net weight 1.01 kg.
- AX80-30-00-83
The ABB AX80-30-00-83 is an AC contactor with three normally open main contacts and no auxiliary contacts. It is rated for a main and auxiliary circuit operational voltage of 690 V and a rated frequency of 50/60 Hz. The conventional free-air thermal current is 125 A according to IEC 60947-4-1 at 40 °C. Rated operational current AC-3 is 80 A at 415 V and 55 °C. Rated insulation voltage is 690 V per IEC 60947-4-1 and VDE 0110 (Gr. C). The coil control voltage is 48 V at 50 Hz and 60 Hz. Dimensions are 70 mm wide, 110 mm deep, and 108 mm high, with a net weight of 1.01 kg. Terminals are screw type.
- AX80-30-00-84
ABB AX80-30-00-84 AC contactor, manufacturer ID 1SBL411074R8400. Three main contacts NO, no auxiliary contacts. Rated operational voltage 690 V for main and auxiliary circuits at 50/60 Hz. Rated operational current AC-3: 80 A at 415 V and 55 °C, 46 A at 690 V and 55 °C. Rated operational power AC-3: 37 kW at 380/400 V, 40 kW at 415 V and 690 V. Conventional free-air thermal current 125 A per IEC 60947-4-1 at 40 °C. Rated control circuit voltage 110 V at 50 Hz, 110 to 120 V at 60 Hz. Screw terminals. Dimensions 70 mm wide, 110 mm deep, 108 mm high; net weight 1.01 kg. Maximum mechanical switching frequency 3600 cycles per hour.
- AX80-30-00-85
The ABB AX80-30-00-85 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It is rated 690 V for both main and auxiliary circuits at 50/60 Hz. Conventional free-air thermal current is 125 A per IEC 60947-4-1 at 40 °C with open contactors. AC-3 ratings include 80 A at 415 V and 46 A at 690 V, both at 55 °C, corresponding to 40 kW at 415 V and 40 kW at 690 V. The coil operates at 50 Hz 380–400 V or 60 Hz 400–415 V. Dimensions are 70 mm wide, 110 mm deep, and 108 mm high; net weight 1.01 kg. Terminals are screw type. Maximum mechanical switching frequency is 3600 cycles per hour.
- AX80-30-00-86
The ABB AX80-30-00-86 is a block-type AC contactor with three normally open main poles and no auxiliary contacts. It is rated 690 V for both main and auxiliary circuits at 50/60 Hz. Conventional free-air thermal current is 125 A per IEC 60947-4-1 at 40 °C. AC-3 ratings include 80 A at 415 V and 46 A at 690 V, both at 55 °C. AC-3 power ratings include 37 kW at 380/400 V, 40 kW at 415 V, and 22 kW at 220/230/240 V. The control circuit voltage is 400 to 415 V at 50 Hz and 415 to 440 V at 60 Hz. Dimensions are 70 mm wide, 110 mm deep, and 108 mm high; net weight is 1.01 kg. Terminals are screw type.