- AX80-30-00-81
The ABB AX80-30-00-81 is an AC contactor with three main poles, normally open (NO), and no auxiliary contacts. Its main and auxiliary circuits are rated 690 V at 50/60 Hz. Rated operational current AC-3 (Ie) is 80 A at 380/400 V, 415 V, and 220/230/240 V, all at 55 °C; 70 A at 440 V; 65 A at 500 V; and 46 A at 690 V. Rated operational power AC-3 (Pe) is 37 kW at 380/400 V, 40 kW at 415 V, 440 V, and 690 V, 45 kW at 500 V, and 22 kW at 220/230/240 V. Conventional free-air thermal current (Ith) is 125 A per IEC 60947-4-1 at 40 °C. Control circuit voltage (Uc) is 24 V at 50 Hz and 60 Hz. Dimensions are 70 mm wide, 110 mm deep, and 108 mm high; net weight 1.01 kg.
- AX80-30-00-83
The ABB AX80-30-00-83 is an AC contactor with three normally open main contacts and no auxiliary contacts. It is rated for a main and auxiliary circuit operational voltage of 690 V and a rated frequency of 50/60 Hz. The conventional free-air thermal current is 125 A according to IEC 60947-4-1 at 40 °C. Rated operational current AC-3 is 80 A at 415 V and 55 °C. Rated insulation voltage is 690 V per IEC 60947-4-1 and VDE 0110 (Gr. C). The coil control voltage is 48 V at 50 Hz and 60 Hz. Dimensions are 70 mm wide, 110 mm deep, and 108 mm high, with a net weight of 1.01 kg. Terminals are screw type.
- AX80-30-00-84
ABB AX80-30-00-84 AC contactor, manufacturer ID 1SBL411074R8400. Three main contacts NO, no auxiliary contacts. Rated operational voltage 690 V for main and auxiliary circuits at 50/60 Hz. Rated operational current AC-3: 80 A at 415 V and 55 °C, 46 A at 690 V and 55 °C. Rated operational power AC-3: 37 kW at 380/400 V, 40 kW at 415 V and 690 V. Conventional free-air thermal current 125 A per IEC 60947-4-1 at 40 °C. Rated control circuit voltage 110 V at 50 Hz, 110 to 120 V at 60 Hz. Screw terminals. Dimensions 70 mm wide, 110 mm deep, 108 mm high; net weight 1.01 kg. Maximum mechanical switching frequency 3600 cycles per hour.
- AX80-30-00-85
The ABB AX80-30-00-85 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It is rated 690 V for both main and auxiliary circuits at 50/60 Hz. Conventional free-air thermal current is 125 A per IEC 60947-4-1 at 40 °C with open contactors. AC-3 ratings include 80 A at 415 V and 46 A at 690 V, both at 55 °C, corresponding to 40 kW at 415 V and 40 kW at 690 V. The coil operates at 50 Hz 380–400 V or 60 Hz 400–415 V. Dimensions are 70 mm wide, 110 mm deep, and 108 mm high; net weight 1.01 kg. Terminals are screw type. Maximum mechanical switching frequency is 3600 cycles per hour.
- AX80-30-00-86
The ABB AX80-30-00-86 is a block-type AC contactor with three normally open main poles and no auxiliary contacts. It is rated 690 V for both main and auxiliary circuits at 50/60 Hz. Conventional free-air thermal current is 125 A per IEC 60947-4-1 at 40 °C. AC-3 ratings include 80 A at 415 V and 46 A at 690 V, both at 55 °C. AC-3 power ratings include 37 kW at 380/400 V, 40 kW at 415 V, and 22 kW at 220/230/240 V. The control circuit voltage is 400 to 415 V at 50 Hz and 415 to 440 V at 60 Hz. Dimensions are 70 mm wide, 110 mm deep, and 108 mm high; net weight is 1.01 kg. Terminals are screw type.
- AX80-30-00-88
ABB AX80-30-00-88 AC contactor, manufacturer ID 1SBL411074R8800. Three main contacts NO, no auxiliary contacts. Rated operational voltage 690 V for main and auxiliary circuits, 50/60 Hz. Conventional free-air thermal current 125 A per IEC 60947-4-1 at 40 °C. AC-3 ratings include 80 A at 415 V and 55 °C, 46 A at 690 V and 55 °C, and 37 kW at 380/400 V. Coil voltage 230 to 240 V at 50 Hz or 240 to 260 V at 60 Hz. Screw terminals, IP20 coil terminals and IP10 main terminals per IEC 60529. Dimensions 70 mm wide, 110 mm deep, 108 mm high; net weight 1.01 kg. Maximum operating altitude 3000 m without derating.
- AX80-30-11-26
The ABB AX80-30-11-26 is a block-type AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 82 mm wide, 110 mm deep, and 108 mm high, and weighs 1.05 kg. Main and auxiliary circuits are rated 690 V at 50/60 Hz. Conventional free-air thermal current is 125 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 80 A at 415 V and 55 °C, and rated operational power AC-3 is 40 kW at 415 V. Maximum mechanical switching frequency is 3600 cycles per hour. Manufacturer ID: 1SBL411074R2611.
- AX80-30-11-36
ABB AX80-30-11-36 AC contactor, manufacturer ID 1SBL411074R3611. Three main contacts NO and no main contacts NC; one auxiliary contact NO and one NC. Rated operational voltage 690 V for main and auxiliary circuits, rated frequency 50/60 Hz. Conventional free-air thermal current 125 A according to IEC 60947-4-1 at 40 °C. Rated operational current AC-3: 80 A at 380/400 V and 415 V, 70 A at 440 V, 65 A at 500 V, 46 A at 690 V, all at 55 °C. Rated control circuit voltage 190 V at 50 Hz and 220 V at 60 Hz. Screw terminals; dimensions 82 mm width, 110 mm depth, 108 mm height; net weight 1.05 kg. Degree of protection: coil terminals IP20, main terminals IP10.