- AX80-30-11-26
The ABB AX80-30-11-26 is a block-type AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 82 mm wide, 110 mm deep, and 108 mm high, and weighs 1.05 kg. Main and auxiliary circuits are rated 690 V at 50/60 Hz. Conventional free-air thermal current is 125 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 80 A at 415 V and 55 °C, and rated operational power AC-3 is 40 kW at 415 V. Maximum mechanical switching frequency is 3600 cycles per hour. Manufacturer ID: 1SBL411074R2611.
- AX80-30-11-36
ABB AX80-30-11-36 AC contactor, manufacturer ID 1SBL411074R3611. Three main contacts NO and no main contacts NC; one auxiliary contact NO and one NC. Rated operational voltage 690 V for main and auxiliary circuits, rated frequency 50/60 Hz. Conventional free-air thermal current 125 A according to IEC 60947-4-1 at 40 °C. Rated operational current AC-3: 80 A at 380/400 V and 415 V, 70 A at 440 V, 65 A at 500 V, 46 A at 690 V, all at 55 °C. Rated control circuit voltage 190 V at 50 Hz and 220 V at 60 Hz. Screw terminals; dimensions 82 mm width, 110 mm depth, 108 mm height; net weight 1.05 kg. Degree of protection: coil terminals IP20, main terminals IP10.
- AX80-30-11-75
The ABB AX80-30-11-75 is a block-type AC contactor with three main poles (3 NO, 0 NC) and one auxiliary NO plus one auxiliary NC contact. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Conventional free-air thermal current is 125 A per IEC 60947-4-1 at 40 °C. AC-3 ratings include 80 A at 415 V and 55 °C, and 46 A at 690 V and 55 °C. Rated control circuit voltage is 200 V at 50 Hz and 200 to 220 V at 60 Hz. Screw terminals; coil terminals IP20 per IEC 60529. Dimensions are 82 mm wide, 110 mm deep, and 108 mm high, weighing 1.05 kg.
- AX80-30-11-80
The ABB AX80-30-11-80 is an AC contactor with three main poles (3 NO, 0 NC) and one auxiliary NO plus one NC contact. It uses screw terminals and measures 82 mm wide, 110 mm deep, and 108 mm high, weighing 1.05 kg. The rated operational voltage is 690 V for both main and auxiliary circuits at 50/60 Hz. Rated operational current AC-3 is 80 A at 380/400 V and 415 V, and 46 A at 690 V, all at 55 °C. Rated control circuit voltage is 220 to 230 V at 50 Hz and 230 to 240 V at 60 Hz. Conventional free-air thermal current is 125 A according to IEC 60947-4-1 for open contactors at 40 °C.
- AX80-30-11-81
The ABB AX80-30-11-81 is an AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. The main and auxiliary circuits are rated 690 V, with a rated frequency of 50 / 60 Hz. The control circuit voltage is 24 V at both 50 Hz and 60 Hz. Rated operational current AC-3 is 80 A at 380 / 400 V, 415 V, and 220 / 230 / 240 V at 55 °C, and 46 A at 690 V at 55 °C. Rated operational power AC-3 is 37 kW at 380 / 400 V and 40 kW at 415 V. Conventional free-air thermal current is 125 A according to IEC 60947-4-1 at 40 °C. Dimensions are 82 mm wide, 110 mm deep, and 108 mm high; net weight is 1.05 kg.
- AX80-30-11-83
ABB AC contactor AX80-30-11-83, manufacturer ID 1SBL411074R8311. It has three main NO contacts, no main NC contacts, and one auxiliary NO plus one auxiliary NC contact, with screw terminals. Rated operational voltage is 690 V for both main and auxiliary circuits at 50/60 Hz. Rated operational current AC-3 is 80 A at 415 V and 55 °C, and AC-3 rated power is 40 kW at 415 V. Conventional free-air thermal current is 125 A per IEC 60947-4-1 at 40 °C. Rated insulation voltage is 690 V per IEC 60947-4-1 and VDE 0110 (Gr. C). Coil voltage is 48 V at 50 Hz and 60 Hz. Dimensions are 82 mm width, 110 mm depth, 108 mm height; net weight 1.05 kg.
- AX80-30-11-84
The ABB AX80-30-11-84 is an AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It has a rated control circuit voltage of 110 V at 50 Hz and 110 to 120 V at 60 Hz. Rated operational voltage is 690 V for both main and auxiliary circuits, with a rated frequency of 50/60 Hz. Conventional free-air thermal current is 125 A according to IEC 60947-4-1 at 40 °C. Rated operational current AC-3 is 80 A at 380/400 V and 415 V, 70 A at 440 V, 65 A at 500 V, and 46 A at 690 V, all at 55 °C. Screw terminals. Dimensions are 82 mm wide, 110 mm deep, and 108 mm high; net weight 1.05 kg.
- AX80-30-11-85
The ABB AX80-30-11-85 is an AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 82 mm wide, 110 mm deep, and 108 mm high, and weighs 1.05 kg. Main and auxiliary circuits are rated 690 V, 50/60 Hz. Rated operational current AC-3 is 80 A at 380/400 V and 415 V, 70 A at 440 V, 65 A at 500 V, and 46 A at 690 V, all at 55 °C. Rated operational power AC-3 is 37 kW at 380/400 V and 40 kW at 415 V, 440 V, and 690 V. The coil is rated 380 to 400 V at 50 Hz and 400 to 415 V at 60 Hz. Terminals are screw type.