Product Model
AX80-30-11-85
Material Number
1SBL411074R8511
Manufacturer
ABB
Product ID
74120

Get a Free Quote

Request pricing and availability for AX80-30-11-85.

More parts to source? Send your whole list in one enquiry

Key specifications

Product Net Weight
1.05 kg
Rated Operational Voltage
Auxiliary Circuit 690 V Main Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz Main Circuit 50 / 60 Hz
Rated Operational Current AC-1 (Ie)
(220 / 240 V) 55 °C 105 A (690 V) 40 °C 125 A (690 V) 70 °C 85 A
Rated Operational Power AC-3 (Pe)
(415 V) 40 kW (440 V) 40 kW (500 V) 45 kW (690 V) 40 kW (380 / 400 V) 37 kW (220 / 230 / 240 V) 22 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 650 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 135 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 370 A
See all specifications

Product Highlights

  1. Coil Voltage: 50 Hz 380 to 400 V and 60 Hz 400 to 415 V
  2. Main Circuit: 690 V rated operational voltage with 3 NO and 0 NC main contacts
  3. Auxiliary Circuit: 690 V rated operational voltage at 50 / 60 Hz with 1 NO and 1 NC auxiliary contacts
  4. Thermal Current: 125 A conventional free-air thermal current (Ith) to IEC 60947-4-1 for open contactors at 40 °C
  5. AC-1 Current: 105 A at 220 / 240 V and 55 °C, 125 A at 690 V and 40 °C, 85 A at 690 V and 70 °C
  6. AC-3 Ratings: 80 A at 380 / 400 V, 415 V, and 220 / 230 / 240 V, 70 A at 440 V, 65 A at 500 V, and 46 A at 690 V, all at 55 °C
  7. AC-3 Power: 37 kW at 380 / 400 V, 40 kW at 415 V, 440 V, and 690 V, 45 kW at 500 V, 22 kW at 220 / 230 / 240 V
  8. Short-time Withstand Current: 1000 A for 1 s, 650 A for 10 s, 370 A for 30 s, 250 A for 1 min, and 135 A for 15 min at 40 °C in free air from a cold state
  9. Switching Frequency: 600 cycles per hour electrical (AC-1 and AC-3) and 3600 cycles per hour mechanical
  10. Operate Time: 8 to 27 ms coil energization to NO closing, 7 to 22 ms coil energization to NC opening, 4 to 11 ms coil de-energization to NO opening, 7 to 14 ms coil de-energization to NC closing
  11. Terminations: Screw terminals with tightening torque of 35 in·lb for the main circuit and 9 in·lb for auxiliary and control circuits
  12. Protection: IP20 coil terminals and IP10 main terminals to IEC 60529, IEC 60947-1, and EN 60529
  13. Ambient Temperature: -40 to 70 °C near contactor in free air, -25 to 55 °C close to contactor fitted with thermal overload relay, and -60 to +80 °C for storage
  14. Dimensions and Weight: 82 mm width, 110 mm depth, 108 mm height, 1.05 kg net weight
AX80-30-11-85

Product Information

Technical Specifications

Specifications for AX80-30-11-85

ParameterValue
Product Net Width82 mm
Product Net Depth / Length110 mm
Product Net Height108 mm
Product Net Weight1.05 kg
Number of Main Contacts NO3
Number of Main Contacts NC0
Number of Auxiliary Contacts NO1
Number of Auxiliary Contacts NC1
Rated Operational VoltageAuxiliary Circuit 690 V Main Circuit 690 V
Rated Frequency (f)Auxiliary Circuit 5060 Hz Main Circuit 5060 Hz
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 125 A
Rated Operational Current AC-1 (Ie)(220 / 240 V) 55 °C 105 A (690 V) 40 °C 125 A (690 V) 70 °C 85 A
Rated Operational Current AC-3 (Ie)(415 V) 55 °C 80 A (440 V) 55 °C 70 A (500 V) 55 °C 65 A (690 V) 55 °C 46 A (380400 V) 55 °C 80 A (220230240 V) 55 °C 80 A
Rated Operational Power AC-3 (Pe)(415 V) 40 kW (440 V) 40 kW (500 V) 45 kW (690 V) 40 kW (380400 V) 37 kW (220230240 V) 22 kW
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 650 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 135 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 370 A
Maximum Breaking Capacitycos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1300 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 630 A
Maximum Electrical Switching Frequency(AC-1) 600 cycles per hour (AC-3) 600 cycles per hour
ParameterValue
Rated Insulation Voltage (Ui)acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (Uimp)Auxiliary Circuit 6 kV
Maximum Mechanical Switching Frequency3600 cycles per hour
Rated Control Circuit Voltage (Uc)50 Hz 380 ... 400 V 60 Hz 400 ... 415 V
Operate TimeBetween Coil De-energization and NC Contact Closing 7 ... 14 ms Between Coil De-energization and NO Contact Opening 4 ... 11 ms Between Coil Energization and NC Contact Opening 7 ... 22 ms Between Coil Energization and NO Contact Closing 8 ... 27 ms
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Terminal TypeScrew Terminals
General Use Rating UL/CSA(600 V AC) 105 A
Horsepower Rating UL/CSA(120 V AC) Single Phase 7-1/2 hp (200 ... 208 V AC) Three Phase 25 hp (220 ... 240 V AC) Three Phase 30 hp (240 V AC) Single Phase 15 hp (440 ... 480 V AC) Three Phase 60 hp (550 ... 600 V AC) Three Phase 75 hp
Tightening Torque UL/CSAAuxiliary Circuit 9 in·lb Control Circuit 9 in·lb Main Circuit 35 in·lb
Ambient Air TemperatureClose to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C Close to Contactor without Thermal O/L Relay -40 ... 70 °C Close to Contactor for Storage -60 ... +80 °C Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic Withstandacc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
Maximum Operating Altitude PermissibleWithout Derating 3000 m
Object Classification CodeQ
ETIM 7EC000066 - Power contactor, AC switching
ETIM 8EC000066 - Power contactor, AC switching
ETIM 9EC000066 - Power contactor, AC switching
eClassV11.0 : 27371003
UNSPSC39121529
IDEA Granular Category Code (IGCC)4755 >> Contactors
Manufacturer ID1SBL411074R8511

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.