- AF146B-30-22RT-12
The ABB AF146B-30-22RT-12 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It measures 90 mm wide, 126 mm deep, and 150 mm high, and weighs 1.3 kg. The main circuit is rated 1000 V. Rated operational current AC-3 is 146 A at 380/400 V and 415 V at 55 °C, and rated operational power AC-3 is 75 kW at 380/400 V and 415 V. Applicable standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1. Manufacturer ID: 1SFL467062R1222.
- AF146B-30-22RT-13
The ABB AF146B-30-22RT-13 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It measures 90 mm wide, 126 mm deep, and 150 mm high, and weighs 1.3 kg. The main circuit is rated for 1000 V operational voltage. AC-3 ratings include 146 A at 415 V and 55 °C, 130 A at 440 V and 55 °C, 93 A at 690 V and 55 °C, and 60 A at 1000 V and 55 °C, with corresponding AC-3 power ratings of 75 kW at 415 V and 90 kW at 440 V, 500 V, and 690 V. It is declared to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AF146B-30-22RT-14
The ABB AF146B-30-22RT-14 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It measures 90 mm wide, 126 mm deep, and 150 mm high, and weighs 1.3 kg. The main circuit is rated 1000 V. Rated operational current AC-1 is 225 A at 40 °C and 1000 V; AC-3 ratings include 146 A at 415 V and 55 °C, and 130 A at 440 V and 55 °C. Rated operational power AC-3 is 75 kW at 415 V and 90 kW at 440 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AF16-22-00-11
The ABB AF16-22-00-11 is a 4-pole AC contactor with two normally open and two normally closed main contacts, and no auxiliary contacts. It is rated 690 V in the main circuit and accepts a control circuit voltage of 24 to 60 V at 50 or 60 Hz, or 20 to 60 V DC. Rated operational current is 30 A in AC-1 at 690 V and 40 °C, and 18 A in AC-3 at 415 V and 60 °C. Rated operational power in AC-3 is 7.5 kW at 400 V and 9 kW at 415 V. It uses screw terminals, mounts on 35 mm DIN rail, measures 45 mm wide by 77 mm deep by 86 mm high, and weighs 0.27 kg. Standards include IEC/EN 60947-1 and IEC/EN 60947-4-1.
- AF16-22-00-12
The ABB AF16-22-00-12 is a 4-pole AC contactor with two normally open and two normally closed main contacts, and no auxiliary contacts. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.27 kg. The main circuit is rated 690 V, with a rated frequency of 50/60 Hz for both control and main circuits. Conventional free-air thermal current is 35 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 30 A at 690 V and 40 °C or 60 °C, and 26 A at 70 °C. Rated insulation voltage is 690 V per IEC 60947-4-1 and 600 V per UL/CSA. Rated impulse withstand voltage is 6 kV. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, CAN/CSA C22.2 No.60947-4-1.
- AF16-22-00-13
The ABB AF16-22-00-13 is a four-pole AC contactor with two normally open and two normally closed main contacts, and no auxiliary contacts. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.27 kg. The main circuit is rated 690 V, with a rated insulation voltage of 690 V according to IEC 60947-4-1 and 600 V according to UL/CSA, and a rated impulse withstand voltage of 6 kV. Rated frequency is 50/60 Hz for both control and main circuits. Conventional free-air thermal current is 35 A according to IEC 60947-4-1 for open contactors at 40 degrees C. Rated operational current AC-1 is 30 A at 690 V and 40 or 60 degrees C, and 26 A at 70 degrees C. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, and CAN/CSA C22.2 No.60947-4-1.
- AF16-22-00-14
The ABB AF16-22-00-14 is a 4-pole AC contactor with two normally open and two normally closed main contacts, and no auxiliary contacts. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.31 kg. The main circuit is rated 690 V, with a rated insulation voltage of 690 V according to IEC 60947-4-1 and 600 V according to UL/CSA, and a rated impulse withstand voltage of 6 kV. Rated operational current AC-3 is 18 A at 415 V and 440 V, 15 A at 500 V, and 10.5 A at 690 V, all at 60 °C. Rated operational power AC-3 is 7.5 kW at 400 V and 9 kW at 415 V, 440 V, 500 V, and 690 V. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, and CAN/CSA C22.2 No.60947-4-1.
- AF16-22-00K-11
The ABB AF16-22-00K-11 is an AC contactor with two normally open and two normally closed main contacts, and no auxiliary contacts. Its main circuit is rated 690 V at 50/60 Hz, with AC-1 rated operational current of 30 A at 40 °C and 60 °C and 26 A at 70 °C at 690 V. AC-3 ratings include 18 A at 415 V and 18 A at 440 V, both at 60 °C. The control circuit accepts 24 to 60 V at 50 Hz and 60 Hz, and 20 to 60 V DC. Terminals are push-in spring type, with main and coil terminals rated IP20. Dimensions are 45 mm wide, 77 mm deep, and 92.3 mm high, weighing 0.285 kg. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 508, and CSA C22.2 No. 60947-1-13 and No. 60947-4-1.