- AF16-22-00-14
The ABB AF16-22-00-14 is a 4-pole AC contactor with two normally open and two normally closed main contacts, and no auxiliary contacts. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.31 kg. The main circuit is rated 690 V, with a rated insulation voltage of 690 V according to IEC 60947-4-1 and 600 V according to UL/CSA, and a rated impulse withstand voltage of 6 kV. Rated operational current AC-3 is 18 A at 415 V and 440 V, 15 A at 500 V, and 10.5 A at 690 V, all at 60 °C. Rated operational power AC-3 is 7.5 kW at 400 V and 9 kW at 415 V, 440 V, 500 V, and 690 V. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, and CAN/CSA C22.2 No.60947-4-1.
- AF16-22-00K-11
The ABB AF16-22-00K-11 is an AC contactor with two normally open and two normally closed main contacts, and no auxiliary contacts. Its main circuit is rated 690 V at 50/60 Hz, with AC-1 rated operational current of 30 A at 40 °C and 60 °C and 26 A at 70 °C at 690 V. AC-3 ratings include 18 A at 415 V and 18 A at 440 V, both at 60 °C. The control circuit accepts 24 to 60 V at 50 Hz and 60 Hz, and 20 to 60 V DC. Terminals are push-in spring type, with main and coil terminals rated IP20. Dimensions are 45 mm wide, 77 mm deep, and 92.3 mm high, weighing 0.285 kg. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 508, and CSA C22.2 No. 60947-1-13 and No. 60947-4-1.
- AF16-22-00K-12
The ABB AF16-22-00K-12 is an AC contactor with two normally open and two normally closed main contacts, and no auxiliary contacts. It is rated for a main circuit operational voltage of 690 V at 50/60 Hz. Per IEC 60947-4-1, the conventional free-air thermal current is 35 A at 40 °C, and AC-1 operational current is 30 A at 690 V and 40 °C or 60 °C, and 26 A at 70 °C. AC-3 operational power at 400 V is 7.5 kW. The contactor measures 45 mm wide, 77 mm deep, and 92.3 mm high, and weighs 0.285 kg. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 508, CSA C22.2 No. 60947-1-13, and CSA C22.2 No. 60947-4-1.
- AF16-22-00K-13
ABB AF16-22-00K-13 AC contactor with 2 NO and 2 NC main contacts and no auxiliary contacts. Rated operational voltage is 690 V in the main circuit at 50/60 Hz. Rated operational power AC-3 is 7.5 kW at 380/400 V and 9 kW at 415, 440, 500, and 690 V. Rated operational current AC-3 is 18 A at 415 V and 440 V, 15 A at 500 V, and 10.5 A at 690 V, all at 60 °C. Push-in spring terminals; main and coil terminals IP20. Dimensions are 45 mm wide, 77 mm deep, and 92.3 mm high, weighing 0.285 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 508, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-4-1.
- AF16-22-00K-14
ABB AF16-22-00K-14 is a 4-pole AC contactor, manufacturer ID 1SBL177505R1400, with two normally open and two normally closed main contacts and no auxiliary contacts. It measures 45 mm wide, 77 mm deep, and 92.3 mm high, weighing 0.285 kg. Main circuit ratings are 690 V at 50/60 Hz. Conventional free-air thermal current is 35 A per IEC 60947-4-1 at 40 °C. AC-1 rated operational current is 30 A at 690 V and 40 °C or 60 °C, and 26 A at 70 °C. AC-3 ratings include 18 A at 415 V and 60 °C, and 7.5 kW at 400 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 508, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-4-1.
- AF16-30-01-11
The ABB AF16-30-01-11 is a 3-pole AC contactor with three normally open main contacts and one normally closed auxiliary contact. It is rated 690 V for both main and auxiliary circuits, with a rated frequency of 50/60 Hz. Conventional free-air thermal current is 35 A per IEC 60947-4-1 at 40 °C, and 16 A per IEC 60947-5-1 at 40 °C. Rated operational current AC-1 is 30 A at 690 V and 40 °C or 60 °C, and 26 A at 70 °C. AC-3 ratings include 18 A at 415 V and 60 °C, and 10.5 A at 690 V and 60 °C. Dimensions are 45 mm wide, 77 mm deep, and 86 mm high; net weight is 0.27 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AF16-30-01-12
The ABB AF16-30-01-12 is a 3-pole AC contactor with three normally open main contacts and one normally closed auxiliary contact. It is rated for a main circuit operational voltage of 690 V and a frequency of 50/60 Hz. Rated operational current AC-3 is 18 A at 380/400 V and 415 V, 15 A at 500 V, and 10.5 A at 690 V, at 60 °C. Rated operational power AC-3 is 7.5 kW at 400 V and 9 kW at 415, 440, 500, and 690 V. Conventional free-air thermal current is 35 A per IEC 60947-4-1 at 40 °C. Dimensions are 45 mm wide, 77 mm deep, and 86 mm high, with a net weight of 0.27 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AF16-30-01-13
The ABB AF16-30-01-13 is an AC contactor with three normally open main contacts and one normally closed auxiliary contact. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.27 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 18 A at 380/400 V, 415 V, 440 V, and 220/230/240 V, 15 A at 500 V, and 10.5 A at 690 V, all at 60 °C. Rated operational power AC-3 is 7.5 kW at 380/400 V and 4 kW at 220/230/240 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.