- AF16-30-01-14
The ABB AF16-30-01-14 is a 3-pole AC contactor with three normally open main contacts and one normally closed auxiliary contact. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.31 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Conventional free-air thermal current is 35 A according to IEC 60947-4-1 at 40 °C, and 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-3 is 18 A at 415 V and 60 °C, and 10.5 A at 690 V and 60 °C. Applicable standards are IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AF16-30-01K-11
ABB AF16-30-01K-11 is a 3-pole AC contactor, manufacturer ID 1SBL177005R1101. It has 3 main contacts NO, no main contacts NC, and 1 auxiliary contact NC. Dimensions are 45 mm wide, 77 mm deep, and 92.3 mm high, with a net weight of 0.285 kg. It is rated for 690 V operational voltage in main and auxiliary circuits, at 50/60 Hz. Conventional free-air thermal current is 35 A per IEC 60947-4-1 at 40 °C open contactors, and 16 A per IEC 60947-5-1 at 40 °C. Rated operational current AC-3 is 18 A at 415 V and 440 V, 15 A at 500 V, and 10.5 A at 690 V, all at 60 °C. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AF16-30-01K-12
The ABB AF16-30-01K-12 is a 3-pole AC contactor with three normally open main contacts and one normally closed auxiliary contact. It measures 45 mm wide, 77 mm deep, and 92.3 mm high, and weighs 0.285 kg. The control circuit accepts 48 to 130 V at 50 Hz, 60 Hz, or DC. Rated operational power in AC-3 is 7.5 kW at 380/400 V and 9 kW at 415, 440, 500, and 690 V. Conventional free-air thermal current is 35 A per IEC 60947-4-1 at 40 degrees C. Main, auxiliary, and coil terminals are IP20 and use push-in spring terminals. It complies with IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AF16-30-01K-13
The ABB AF16-30-01K-13 is a 3-pole AC contactor with one normally closed auxiliary contact and no normally open auxiliary contacts. It is identified by manufacturer ID 1SBL177005R1301. The contactor measures 45 mm wide, 77 mm deep, and 92.3 mm high, and weighs 0.285 kg. It is rated for a main and auxiliary circuit operational voltage of 690 V at 50/60 Hz. Rated operational power in AC-3 is 7.5 kW at 380/400 V and 4 kW at 220/230/240 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AF16-30-01K-14
The ABB AF16-30-01K-14 is a 3-pole AC contactor with three normally open main contacts and one normally closed auxiliary contact. It measures 45 mm wide, 77 mm deep, and 92.3 mm high, and weighs 0.325 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 18 A at 380/400 V and 415 V, 15 A at 500 V, and 10.5 A at 690 V, all at 60 °C. Rated operational power AC-3 is 7.5 kW at 380/400 V and 9 kW at 415 V, 440 V, 500 V, and 690 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AF16-30-10-11
The ABB AF16-30-10-11 is an AC contactor with three normally open main contacts and one normally open auxiliary contact. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.27 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 18 A at 415 V and 440 V, 15 A at 500 V, and 10.5 A at 690 V, all at 60 °C. Rated operational power AC-3 is 7.5 kW at 400 V and 9 kW at 415 V, 440 V, 500 V, and 690 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AF16-30-10-11*24-60V AC/ 20-60V DC
The ABB AF16-30-10-11 is a contactor supplied in box packaging. Its coil is rated for 24-60 V AC and 20-60 V DC. No further technical parameters, standards, certifications, or application data are provided in the source information. The model designation AF16-30-10-11*24-60V AC/ 20-60V DC is the only identity reference available; no separate manufacturer part number or order code is supplied. Buyers should confirm pole configuration, current rating, auxiliary contacts, and terminal type directly with the manufacturer or an authorized distributor before specifying this item.
- AF16-30-10-12
The ABB AF16-30-10-12 is a 3-pole AC contactor with three normally open main contacts and one normally open auxiliary contact. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.27 kg. Per IEC/EN 60947-4-1, rated operational current AC-3 is 18 A at 415 V and 440 V, 15 A at 500 V, and 10.5 A at 690 V, all at 60 °C. Rated operational power AC-3 is 7.5 kW at 380/400 V and 9 kW at 415 V, 440 V, 500 V, and 690 V. Rated operational voltage is 690 V for main and auxiliary circuits, with 50/60 Hz rated frequency. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.