- NX22E-80
ABB NX22E-80 intermediate relay, manufacturer ID 1SBH901074R8022. It has 2 NO and 2 NC auxiliary contacts, rated operational voltage 690 V for auxiliary and main circuits, and rated frequency 50/60 Hz for both circuits. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated control circuit voltage is 220 to 230 V at 50 Hz and 230 to 240 V at 60 Hz. Dimensions are 44 mm wide, 74 mm deep, and 74 mm high, with a net weight of 0.315 kg. Terminals are screw type; coil terminals are IP20 according to IEC 60529, IEC 60947-1, and EN 60529.
- NX22E-81
ABB NX22E-81 intermediate relay, manufacturer ID 1SBH901074R8122. It has 2 NO and 2 NC auxiliary contacts, rated operational voltage 690 V for both auxiliary and main circuits, rated frequency 50/60 Hz, and a rated control circuit voltage of 24 V at 50 Hz and 24 V at 60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated insulation voltage is 690 V according to IEC 60947-5-1 and VDE 0110 (Gr. C); rated impulse withstand voltage for the auxiliary circuit is 6 kV. Maximum mechanical switching frequency is 6000 cycles per hour. Dimensions are 44 mm wide, 74 mm deep, and 74 mm high; net weight 0.315 kg. Screw terminals; coil terminals IP20 according to IEC 60529, IEC 60947-1, and EN 60529.
- NX22E-83
The ABB NX22E-83 is an intermediate relay with a block-type design and four poles. It has two normally open and two normally closed auxiliary contacts. Rated operational voltage is 690 V for both auxiliary and main circuits, at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated control circuit voltage is 48 V at 50 Hz and 60 Hz. The relay uses screw terminals, measures 44 mm wide by 74 mm deep by 74 mm high, and weighs 0.315 kg. Coil terminals are rated IP20 according to IEC 60529, IEC 60947-1, and EN 60529. Maximum mechanical switching frequency is 6000 cycles per hour.
- NX22E-84
The ABB NX22E-84 is an intermediate relay with 2 normally open and 2 normally closed auxiliary contacts. It measures 44 mm wide, 74 mm deep, and 74 mm high, and weighs 0.315 kg. Rated operational voltage is 690 V for both auxiliary and main circuits, at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated insulation voltage is 690 V per IEC 60947-5-1 and VDE 0110 (Gr. C), with a rated impulse withstand voltage of 6 kV for the auxiliary circuit. Coil control voltage is 110 V at 50 Hz and 110 to 120 V at 60 Hz. Screw terminals are used, with coil terminals rated IP20 per IEC 60529, IEC 60947-1, and EN 60529.
- NX22E-85
The ABB NX22E-85 is an intermediate relay (contactor relay) with manufacturer ID 1SBH901074R8522. It has 2 NO and 2 NC auxiliary contacts, screw terminals, and dimensions of 44 mm width, 74 mm depth, and 74 mm height, weighing 0.315 kg. Rated operational voltage is 690 V for auxiliary and main circuits, with rated frequency 50/60 Hz. Rated control circuit voltage is 380–400 V at 50 Hz and 400–415 V at 60 Hz. Conventional free-air thermal current is 16 A per IEC 60947-5-1 at 40 °C. Rated insulation voltage is 690 V per IEC 60947-5-1 and VDE 0110 Gr. C; rated impulse withstand voltage is 6 kV. Coil terminals are IP20 per IEC 60529, IEC 60947-1, and EN 60529.
- NX22E-86
The ABB NX22E-86 is an intermediate relay with 2 NO and 2 NC auxiliary contacts. Its rated control circuit voltage is 400 to 415 V at 50 Hz and 415 to 440 V at 60 Hz. Conventional free-air thermal current is 16 A at 40 °C according to IEC 60947-5-1. Rated insulation voltage is 690 V per IEC 60947-5-1 and VDE 0110 (Gr. C), and rated impulse withstand voltage for the auxiliary circuit is 6 kV. The relay uses screw terminals, measures 44 mm wide, 74 mm deep, and 74 mm high, and weighs 0.315 kg. Maximum mechanical switching frequency is 6000 cycles per hour. Maximum operating altitude without derating is 3000 m.
- NX22E-88
The ABB NX22E-88 is an intermediate relay with two normally open and two normally closed auxiliary contacts. It measures 44 mm wide, 74 mm deep, and 74 mm high, and weighs 0.315 kg. Rated operational voltage is 690 V for both auxiliary and main circuits, at 50 or 60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated insulation voltage is 690 V according to IEC 60947-5-1 and VDE 0110 (Gr. C), with a rated impulse withstand voltage of 6 kV for the auxiliary circuit. Coil voltage is 230 to 240 V at 50 Hz and 240 to 260 V at 60 Hz. Screw terminals; coil terminals rated IP20 according to IEC 60529, IEC 60947-1, and EN 60529.
- NX31E-26
ABB NX31E-26 intermediate relay, manufacturer ID 1SBH901074R2631. It has 3 normally open and 1 normally closed auxiliary contacts, screw terminals, and dimensions of 44 mm width, 74 mm depth, and 74 mm height, weighing 0.315 kg. Rated operational voltage is 690 V for both auxiliary and main circuits, with rated frequency 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated control circuit voltage is 105 V at 50 Hz and 110 to 127 V at 60 Hz. Rated insulation voltage is 690 V according to IEC 60947-5-1 and VDE 0110 (Gr. C); rated impulse withstand voltage for the auxiliary circuit is 6 kV. Coil terminals are IP20 according to IEC 60529, IEC 60947-1, and EN 60529.