Industrial Automation Parts. Prompt replies from real people.

ABB NX22E-84 SmartLink Contactor Relay

  • Warehouse stock, ready to ship
  • Fully genuine original parts
  • Free quotes within 24 hours
Get a Free Quote

Free quote · Reply within 24 hours

Last Updated: 11/25/2026

Q1Can you supply the ABB NX22E-84?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the ABB NX22E-84 cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
NX22E-84
Material Number
1SBH901074R8422
Manufacturer
ABB
Product ID
74300

Get a Free Quote

Request pricing and availability for NX22E-84.

More parts to source? Send your whole list in one enquiry

Key specifications

Product Net Weight
0.315 kg
Rated Operational Voltage
Auxiliary Circuit 690 V Main Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz Main Circuit 50 / 60 Hz
Rated Operational Current AC-15 (Ie)
(500 V) NC 2 (500 V) 2 A (690 V) 2 A (24 / 127 V) 6 A (220 / 240 V) 4 A (380 / 400 V) 3 A (400 / 440 V) 2 A
Rated Short-time Withstand Current Low Voltage (Icw)
for 0.1 s 140 A for 1 s 100 A
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
See all specifications

Product Highlights

  1. Contact Configuration: 4-pole contactor relay with 2 NO and 2 NC auxiliary contacts
  2. Rated Operational Voltage: 690 V for both auxiliary and main circuits at 50 / 60 Hz
  3. Thermal Current: 16 A conventional free-air thermal current (Ith) according to IEC 60947-5-1 at 40 °C
  4. Switching Capacity: AC-15 rated operational current from 6 A at 24 / 127 V to 2 A at 690 V, DC-13 from 6 A / 144 W at 24 V to 0.30 A / 75 W at 250 V
  5. Short-time Withstand: 140 A for 0.1 s and 100 A for 1 s
  6. Switching Frequency: Maximum electrical 1200 cycles per hour for AC-15 and 900 cycles per hour for DC-13, maximum mechanical 6000 cycles per hour
  7. Insulation and Impulse Withstand: Rated insulation voltage 690 V according to IEC 60947-5-1 and VDE 0110 (Gr. C), rated impulse withstand voltage 6 kV for the auxiliary circuit
  8. Coil and Operate Time: Rated control circuit voltage 110 V at 50 Hz and 110 ... 120 V at 60 Hz, operate time 4 ... 26 ms depending on contact and energization state
  9. Terminals and Protection: Screw terminals with 9 in·lb tightening torque for auxiliary and control circuits, coil terminals IP20 according to IEC 60529
  10. Ambient Air Temperature: -40 ... 70 °C near contactor for operation in free air, -25 ... 55 °C close to contactor fitted with thermal overload relay, -60 ... +80 °C for storage
  11. Dimensions and Weight: 44 mm width, 74 mm depth, 74 mm height, 0.315 kg net weight
NX22E-84

Product Information

Technical Specifications

Specifications for NX22E-84

ParameterValue
Product Net Width44 mm
Product Net Depth / Length74 mm
Product Net Height74 mm
Product Net Weight0.315 kg
Number of Auxiliary Contacts NO2
Number of Auxiliary Contacts NC2
Rated Operational VoltageAuxiliary Circuit 690 V Main Circuit 690 V
Rated Frequency (f)Auxiliary Circuit 5060 Hz Main Circuit 5060 Hz
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-5-1, Θ = 40 °C 16 A
Rated Operational Current AC-15 (Ie)(500 V) NC 2 (500 V) 2 A (690 V) 2 A (24127 V) 6 A (220240 V) 4 A (380400 V) 3 A (400440 V) 2 A
Rated Short-time Withstand Current Low Voltage (Icw)for 0.1 s 140 A for 1 s 100 A
Maximum Electrical Switching Frequency(AC-15) 1200 cycles per hour (DC-13) 900 cycles per hour
Rated Operational Current DC-13 (Ie)(24 V) 6 A144 W (110 V) 0.55 A60 W (125 V) 0.55 A69 W (220 V) 0.30 A66 W (250 V) 0.30 A75 W (400 V) 2.8 A134 W (500 V) 1 A72 W
Rated Insulation Voltage (Ui)acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 690 V
ParameterValue
Rated Impulse Withstand Voltage (Uimp)Auxiliary Circuit 6 kV
Maximum Mechanical Switching Frequency6000 cycles per hour
Rated Control Circuit Voltage (Uc)50 Hz 110 V 60 Hz 110 ... 120 V
Operate TimeBetween Coil De-energization and NC Contact Closing 9 ... 16 ms Between Coil De-energization and NO Contact Opening 4 ... 11 ms Between Coil Energization and NC Contact Opening 7 ... 21 ms Between Coil Energization and NO Contact Closing 10 ... 26 ms
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
Terminal TypeScrew Terminals
Tightening Torque UL/CSAAuxiliary Circuit 9 in·lb Control Circuit 9 in·lb
Ambient Air TemperatureClose to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C Close to Contactor without Thermal O/L Relay -40 ... 70 °C Close to Contactor for Storage -60 ... +80 °C Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic Withstandacc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
Maximum Operating Altitude PermissibleWithout Derating 3000 m
Object Classification CodeK
ETIM 7EC000196 - Contactor relay
ETIM 8EC000196 - Contactor relay
ETIM 9EC000196 - Contactor relay
eClassV11.0 : 27371001
UNSPSC39121500
IDEA Granular Category Code (IGCC)4755 >> Contactors
E-Number (Finland)3707377
Manufacturer ID1SBH901074R8422

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.