- NX31E-75
ABB NX31E-75 intermediate relay, manufacturer ID 1SBH901074R7531. It has 3 normally open and 1 normally closed auxiliary contacts, a rated operational voltage of 690 V for both auxiliary and main circuits, and a rated frequency of 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated insulation voltage is 690 V according to IEC 60947-5-1 and VDE 0110 (Gr. C); rated impulse withstand voltage for the auxiliary circuit is 6 kV. Dimensions are 44 mm wide, 74 mm deep, 74 mm high, and 0.315 kg. Screw terminals; coil terminals IP20 according to IEC 60529, IEC 60947-1, and EN 60529.
- NX31E-80
The ABB NX31E-80 is an intermediate relay (contactor relay) with 3 normally open and 1 normally closed auxiliary contacts. Its rated control circuit voltage is 220 to 230 V at 50 Hz and 230 to 240 V at 60 Hz. Rated operational voltage is 690 V for both auxiliary and main circuits, with rated insulation voltage 690 V to IEC 60947-5-1 and VDE 0110 (Gr. C), and rated impulse withstand voltage 6 kV for the auxiliary circuit. Conventional free-air thermal current is 16 A to IEC 60947-5-1 at 40 °C. Maximum mechanical switching frequency is 6000 cycles per hour. Dimensions are 44 mm wide, 74 mm deep, and 74 mm high; net weight 0.315 kg. Coil terminals are IP20 to IEC 60529, IEC 60947-1, and EN 60529. Terminals are screw type.
- NX31E-83
ABB NX31E-83 intermediate relay, manufacturer ID 1SBH901074R8331. It has 3 NO and 1 NC auxiliary contacts, screw terminals, and a rated operational voltage of 690 V for both auxiliary and main circuits at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated insulation voltage is 690 V per IEC 60947-5-1 and VDE 0110 (Gr. C); rated impulse withstand voltage is 6 kV for the auxiliary circuit. Control circuit voltage is 48 V at 50 Hz and 48 V at 60 Hz. Maximum mechanical switching frequency is 6000 cycles per hour; maximum electrical switching frequency is 1200 cycles per hour (AC-15) and 900 cycles per hour (DC-13). Dimensions are 44 mm wide, 74 mm deep, 74 mm high; net weight 0.315 kg.
- NX31E-85
ABB NX31E-85 intermediate relay, manufacturer ID 1SBH901074R8531. It has 3 normally open and 1 normally closed auxiliary contacts. Rated operational voltage is 690 V for both auxiliary and main circuits, at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated insulation voltage is 690 V according to IEC 60947-5-1 and VDE 0110 (Gr. C); rated impulse withstand voltage for the auxiliary circuit is 6 kV. Dimensions are 44 mm wide, 74 mm deep, and 74 mm high, with a net weight of 0.315 kg. Screw terminals are used. Coil terminals have IP20 protection according to IEC 60529, IEC 60947-1, and EN 60529.
- NX31E-86
The ABB NX31E-86 is an intermediate relay (contactor relay) with manufacturer ID 1SBH901074R8631. It has 3 NO and 1 NC auxiliary contacts and screw terminals. The rated control circuit voltage is 400 to 415 V at 50 Hz and 415 to 440 V at 60 Hz. Rated operational voltage is 690 V for both auxiliary and main circuits, at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated insulation voltage is 690 V according to IEC 60947-5-1 and VDE 0110 (Gr. C); rated impulse withstand voltage is 6 kV for the auxiliary circuit. Dimensions are 44 mm wide, 74 mm deep, 74 mm high, weight 0.315 kg.
- NX31E-88
The ABB NX31E-88 is a 4-pole contactor relay with 3 normally open and 1 normally closed auxiliary contacts. It is AC-operated with a rated control circuit voltage of 50 Hz 230 to 240 V or 60 Hz 240 to 260 V. The rated operational voltage is 690 V for both auxiliary and main circuits, at 50 or 60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 degrees C. Rated insulation voltage is 690 V according to IEC 60947-5-1 and VDE 0110 (Gr. C); rated impulse withstand voltage for the auxiliary circuit is 6 kV. Dimensions are 44 mm wide, 74 mm deep, and 74 mm high, with a net weight of 0.315 kg. Screw terminals.
- NX40E-26
ABB NX40E-26 intermediate relay, manufacturer ID 1SBH901074R2640, with four normally open auxiliary contacts and no normally closed contacts. Rated operational voltage is 690 V for both auxiliary and main circuits at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-15 is 2 A at 690 V and 6 A at 24/127 V; DC-13 ratings include 6 A/144 W at 24 V. Rated insulation voltage is 690 V per IEC 60947-5-1 and VDE 0110 (Gr. C); rated impulse withstand voltage is 6 kV. Maximum electrical switching frequency is 1200 cycles per hour (AC-15) and 900 cycles per hour (DC-13). Dimensions are 44 mm wide, 74 mm deep, 74 mm high; weight 0.315 kg. Screw terminals; coil terminals IP20.
- NX40E-36
The ABB NX40E-36 is a 4-pole contactor relay for auxiliary circuits, identified by manufacturer ID 1SBH901074R3640. It has four normally open auxiliary contacts and no normally closed contacts. The rated control circuit voltage is 190 V at 50 Hz and 220 V at 60 Hz. Rated operational voltage is 690 V for both auxiliary and main circuits, with rated frequency 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Maximum electrical switching frequency is 1200 cycles per hour for AC-15 and 900 cycles per hour for DC-13. Dimensions are 44 mm wide, 74 mm deep, and 74 mm high; net weight is 0.315 kg. Terminals are screw type.