- UA110-30-11-83
The ABB UA110-30-11-83 is a three-phase AC contactor for capacitor duty, identified by manufacturer ID 1SFL451022R8311. It has three normally open main contacts, one normally open auxiliary contact, and one normally closed auxiliary contact. The main circuit is rated 1000 V at 50/60 Hz, with a rated insulation voltage of 1000 V according to IEC 60947-4-1 and VDE 0110 (Gr. C), and 600 V according to UL/CSA. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 degrees C. Rated operational power in AC-6b is 40 kvar at 230/240 V, 50/60 Hz, 40 degrees C. Dimensions are 102 mm wide, 123.5 mm deep, and 148 mm high; net weight is 1.8 kg.
- UA110-30-11-84
ABB UA110-30-11-84 is a 3-phase AC contactor with three normally open main contacts, one normally open auxiliary contact, and one normally closed auxiliary contact. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational power AC-6b is 40 kvar at 230/240 V and 40 °C, 40 kvar at 230/240 V and 55 °C, 35 kvar at 230/240 V and 70 °C, and 75 kvar at 400/415 V and 40 °C, all at 50/60 Hz. Rated insulation voltage is 1000 V per IEC 60947-4-1 and VDE 0110 (Gr. C), and 600 V per UL/CSA. Rated impulse withstand voltage is 8 kV. Mechanical durability is 10 million operations. Dimensions are 102 mm wide, 123.5 mm deep, and 148 mm high; net weight is 1.8 kg.
- UA110-30-11-85
The ABB UA110-30-11-85 is a three-phase AC contactor for capacitor duty, identified by manufacturer ID 1SFL451022R8511. It has three normally open main contacts, no normally closed main contacts, and one normally open plus one normally closed auxiliary contact. The main circuit is rated 1000 V with a rated frequency of 50/60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational power in AC-6b is 40 kvar at 230/240 V and 40 °C, 40 kvar at 55 °C, and 35 kvar at 70 °C, all at 50/60 Hz. Dimensions are 102 mm wide, 123.5 mm deep, and 148 mm high, with a net weight of 1.8 kg.
- UA110-30-11-86
The ABB UA110-30-11-86 is a three-pole AC contactor intended for capacitor switching. It has three normally open main contacts, one normally open auxiliary contact, and one normally closed auxiliary contact. The main circuit is rated 1000 V with a rated frequency of 50/60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational power in AC-6b is 40 kvar at 230/240 V and 40 °C, 50/60 Hz. Rated insulation voltage is 1000 V according to IEC 60947-4-1 and VDE 0110 (Gr. C), and 600 V according to UL/CSA. Rated impulse withstand voltage is 8 kV. Mechanical durability is 10 million operations. Dimensions are 102 mm wide, 123.5 mm deep, and 148 mm high, with a net weight of 1.8 kg.
- UA110-30-22-80
The ABB UA110-30-22-80 is an AC contactor with three main contacts (NO) and two auxiliary contacts each NO and NC. The main circuit is rated 1000 V with a rated frequency of 50/60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated insulation voltage is 1000 V according to IEC 60947-4-1 and VDE 0110 (Gr. C), and 600 V according to UL/CSA. Rated impulse withstand voltage for the main circuit is 8 kV. Mechanical durability is 10 million cycles, with maximum mechanical switching frequency of 3600 cycles per hour. Dimensions are 90 mm wide, 156.5 mm deep, and 148 mm high, weighing 1.8 kg.
- UA110-30-22-85
The ABB UA110-30-22-85 is a 3-phase AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It measures 90 mm wide, 156.5 mm deep, and 148 mm high, and weighs 1.8 kg. The main circuit is rated 1000 V at 50/60 Hz, with a conventional free-air thermal current of 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational power in AC-6b is 40 kvar at 230/240 V and 50/60 Hz at 40 °C and 55 °C, and 35 kvar at 70 °C. Rated insulation voltage is 1000 V per IEC 60947-4-1 and VDE 0110 (Gr. C), and 600 V per UL/CSA. Rated impulse withstand voltage is 8 kV. Mechanical durability is 10 million operations.
- UA115-30-11
The ABB UA115-30-11 is an AC contactor with manufacturer ID 1SFL451067R8011. It has three normally open main contacts, one normally open auxiliary contact, and one normally closed auxiliary contact. Rated operational power in AC-6b is 40 kvar at 230/240 V, 50/60 Hz and 40 °C; 75 kvar at 400/415 V, 50/60 Hz and 40 °C; 80 kvar at 500/550 V, 50/60 Hz and 40 °C; and 90 kvar at 690 V, 50/60 Hz and 40 °C. Rated control circuit voltage is 220 to 230 V at 50 Hz and 230 to 240 V at 60 Hz. Terminals are cable clamp type. Dimensions are 102 mm wide, 123.5 mm deep, and 148 mm high, with a net weight of 2 kg.
- UA16-30-01RA 220-230V 50Hz / 230-240V 60Hz
Product identification: ABB UA16-30-01RA 220-230V 50Hz / 230-240V 60Hz. ABB UA16-30-01RA is a 3-pole AC contactor with three normally open main contacts and one normally closed auxiliary contact. It operates at 220-230 V 50 Hz or 230-240 V 60 Hz. Rated operational voltage is 690 V for main and auxiliary circuits, with rated insulation voltage of 1000 V according to IEC 60947-4-1 and 690 V according to IEC 60947-5-1. Conventional free-air thermal current is 16 A at 40 °C per IEC 60947-5-1. Rated operational power AC-6b is 7.5 kvar at 230/240 V, 40 °C, 50/60 Hz. Dimensions are 35 mm wide, 68 mm deep, and 74 mm high; net weight is 0.46 kg. Standards: IEC/EN 60947-1 and IEC/EN 60947-4-1. Manufacturer ID: 1SBL181024R8001.