- UA16-30-01RA 220-230V 50Hz / 230-240V 60Hz
Product identification: ABB UA16-30-01RA 220-230V 50Hz / 230-240V 60Hz. ABB UA16-30-01RA is a 3-pole AC contactor with three normally open main contacts and one normally closed auxiliary contact. It operates at 220-230 V 50 Hz or 230-240 V 60 Hz. Rated operational voltage is 690 V for main and auxiliary circuits, with rated insulation voltage of 1000 V according to IEC 60947-4-1 and 690 V according to IEC 60947-5-1. Conventional free-air thermal current is 16 A at 40 °C per IEC 60947-5-1. Rated operational power AC-6b is 7.5 kvar at 230/240 V, 40 °C, 50/60 Hz. Dimensions are 35 mm wide, 68 mm deep, and 74 mm high; net weight is 0.46 kg. Standards: IEC/EN 60947-1 and IEC/EN 60947-4-1. Manufacturer ID: 1SBL181024R8001.
- UA16-30-10 110V 50Hz / 110-120V 60Hz
Product identification: ABB UA16-30-10 110V 50Hz / 110-120V 60Hz. ABB UA16-30-10 is a 3-pole AC contactor with three normally open main contacts and one normally open auxiliary contact. It operates at 110 V 50 Hz and 110-120 V 60 Hz. Dimensions are 44 mm wide, 74 mm deep, and 74 mm high; net weight is 0.34 kg. Rated operational voltage is 690 V for main and auxiliary circuits. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated operational power AC-6b is 7.5 kvar at 230/240 V, 40 °C, 50/60 Hz. Standards: IEC/EN 60947-1 and IEC/EN 60947-4-1. Rated insulation voltage is 1000 V per IEC 60947-4-1, 690 V per IEC 60947-5-1, and 600 V per UL/CSA. Rated impulse withstand voltage is 8 kV.
- UA16-30-10 190V 50Hz / 220V 60Hz
Product identification: ABB UA16-30-10 190V 50Hz / 220V 60Hz. ABB UA16-30-10 AC contactor, manufacturer ID 1SBL181022R3610, coil rated for 190 V 50 Hz or 220 V 60 Hz. It has three normally open main contacts and one normally open auxiliary contact, with no normally closed contacts. Dimensions are 44 mm wide, 74 mm deep, and 74 mm high; net weight is 0.34 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, with a rated insulation voltage of 1000 V according to IEC 60947-4-1 and 690 V according to IEC 60947-5-1. Conventional free-air thermal current is 16 A at 40 °C per IEC 60947-5-1. Standards: IEC/EN 60947-1 and IEC/EN 60947-4-1.
- UA16-30-10 220-230V 50Hz / 230-240V 60Hz
Product identification: ABB UA16-30-10 220-230V 50Hz / 230-240V 60Hz. The ABB UA16-30-10 is a 3-pole AC contactor with three normally open main contacts and one normally open auxiliary contact. It operates at 220-230 V 50 Hz or 230-240 V 60 Hz. The contactor is rated for a conventional free-air thermal current of 16 A at 40 °C according to IEC 60947-5-1. It complies with IEC/EN 60947-1 and IEC/EN 60947-4-1. The rated operational voltage is 690 V for both main and auxiliary circuits. The rated insulation voltage is 1000 V according to IEC 60947-4-1, 690 V according to IEC 60947-5-1, and 600 V according to UL/CSA. The rated impulse withstand voltage is 8 kV. Dimensions are 44 mm wide, 74 mm deep, and 74 mm high, with a net weight of 0.34 kg.
- UA16-30-10 230-240V 50Hz / 240-260V 60Hz
Product identification: ABB UA16-30-10 230-240V 50Hz / 240-260V 60Hz. ABB UA16-30-10 is a 3-pole AC contactor with one normally open auxiliary contact and no normally closed auxiliary contacts. It operates at 230-240 V 50 Hz or 240-260 V 60 Hz. Main and auxiliary circuits are rated 690 V, with rated insulation voltage 1000 V to IEC 60947-4-1, 690 V to IEC 60947-5-1, and 600 V to UL/CSA, and rated impulse withstand voltage 8 kV. Conventional free-air thermal current is 16 A at 40 °C to IEC 60947-5-1. Rated operational power AC-6b is 7.5 kvar at 230/240 V, 40 °C, 50/60 Hz. Dimensions are 44 mm wide, 74 mm deep, 74 mm high; net weight 0.34 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1.
- UA16-30-10 230-240V 50Hz / 277V 60Hz
ABB UA16-30-10 230-240V 50Hz / 277V 60Hz is a 3-pole AC contactor with three normally open main contacts and one normally open auxiliary contact. It is rated 16 A conventional free-air thermal current (Ith) according to IEC 60947-5-1 at 40 °C. The control circuit voltage is 230 to 240 V at 50 Hz and 277 V at 60 Hz. It conforms to IEC/EN 60947-1 and IEC/EN 60947-4-1, with a rated insulation voltage of 1000 V according to IEC 60947-4-1 and a rated impulse withstand voltage of 8 kV. Dimensions are 44 mm wide, 74 mm deep, and 74 mm high, with a net weight of 0.34 kg. Terminals are screw type, IP20, and DIN rail mounting is TH35-15 or TH35-7.5 according to IEC 60715.
- UA16-30-10 24V 50Hz / 24V 60Hz
Product identification: ABB UA16-30-10 24V 50Hz / 24V 60Hz. ABB UA16-30-10 AC contactor, manufacturer ID 1SBL181022R8110, with a 24 V 50 Hz / 24 V 60 Hz control circuit. It has three normally open main contacts and one normally open auxiliary contact. Dimensions are 44 mm wide, 74 mm deep, and 74 mm high; net weight is 0.34 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, with a rated frequency of 50 / 60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Standards: IEC/EN 60947-1 and IEC/EN 60947-4-1. Rated insulation voltage is 1000 V per IEC 60947-4-1, 690 V per IEC 60947-5-1, and 600 V per UL/CSA; rated impulse withstand voltage is 8 kV.
- UA16-30-10 380-400V 50Hz / 400-415V 60Hz
Product identification: ABB UA16-30-10 380-400V 50Hz / 400-415V 60Hz. ABB UA16-30-10 AC contactor, order code 1SBL181022R8510, with a coil rated for 380-400 V at 50 Hz and 400-415 V at 60 Hz. It has three normally open main contacts and one normally open auxiliary contact. Rated operational voltage is 690 V for both main and auxiliary circuits, with a rated insulation voltage of 1000 V according to IEC 60947-4-1 and 690 V according to IEC 60947-5-1. Conventional free-air thermal current is 16 A at 40 °C per IEC 60947-5-1. Dimensions are 44 mm wide, 74 mm deep, and 74 mm high, weighing 0.34 kg. Standards: IEC/EN 60947-1 and IEC/EN 60947-4-1.