- OT16ELMM3TZ
ABB OT16ELMM3TZ is a three-pole isolating switch supplied in a steel sheet enclosure with a black selector handle. It is rated for a conventional thermal current (Ithe) of 40 A fully enclosed and a rated insulation voltage (Ui) of 750 V according to IEC/EN 60664-1. The enclosure provides IP65 protection according to IEC 60529, with pollution degree 3. Cable cross-section range is 0.75 to 10 mm², with cable entry from above or below. Dimensions are 146 mm wide, 198 mm high, and 110 mm deep; net weight is 1.6 kg. Power loss is 1.6 W per pole at rated operating conditions. One normally open auxiliary contact is mounted; up to 2 NO and 2 NC can be fitted.
- OT16ELMM4B
The ABB OT16ELMM4B is an enclosed isolating switch supplied under manufacturer ID 1SCA022467R7940. It is a four-pole (4P) device with a black selector handle and a steel sheet enclosure. The enclosure provides IP54 protection according to IEC 60529, with pollution degree 3. Conventional thermal current (Ithe) is 25 A fully enclosed. Rated insulation voltage (Ui) is 750 V according to IEC/EN 60664-1. Power loss is 0.3 W per pole at rated operating conditions. Cable cross-section range is 0.75 to 10 mm², with cable entry up/down and two outlets per side (2xø20+ø16.5 / 2xø20+ø16.5). Dimensions are 146 mm wide, 198 mm high, and 110 mm deep; net weight is 1.6 kg. Up to 2 NO and 2 NC auxiliary contacts can be mounted; none are fitted.
- OT16ELMM4BL
ABB OT16ELMM4BL is a four-pole isolating switch supplied in a steel sheet enclosure with IP54 protection according to IEC 60529. The enclosure measures 176 mm wide, 255 mm high, and 160 mm deep, and weighs 1.6 kg. It uses a black selector handle. Cable entry is from above or below, with two outlets per side (2xø20 + ø16.5). Cable cross-section range is 0.75 to 10 mm². Conventional thermal current (Ithe) is 25 A fully enclosed. Rated insulation voltage is 750 V according to IEC/EN 60664-1, and rated operational voltage for the main circuit is 750 V. Rated operational current AC-22A is 16 A at 380 to 415 V and 16 A at 690 V. Up to two NO and two NC auxiliary contacts can be mounted; none are fitted. Manufacturer ID: 1SCA109976R1001.
- OT16ELMM4BZ
The ABB OT16ELMM4BZ is a four-pole isolating switch in a steel sheet enclosure with a black selector handle. It is rated for a conventional thermal current (Ithe) of 25 A fully enclosed and a rated insulation voltage (Ui) of 750 V according to IEC/EN 60664-1. The enclosure provides IP65 protection according to IEC 60529, with pollution degree 3. Cable cross-section range is 0.75 to 10 mm², with up/down cable entry and two outlets per side (2xø20+ø16.5 / 2xø20+ø16.5). Power loss is 0.3 W per pole at rated operating conditions. Dimensions are 146 mm wide, 198 mm high, and 110 mm deep; net weight is 1.6 kg. Maximum mounted auxiliary contacts are 2 NO and 2 NC; none are mounted. Manufacturer ID: 1SCA022467R9050.
- OT16ELMM4T
The ABB OT16ELMM4T is a four-pole enclosed isolating switch with a selector handle in black. Its steel sheet enclosure provides IP54 protection according to IEC 60529, with pollution degree 3. Rated insulation voltage is 750 V per IEC/EN 60664-1, and rated operational voltage for the main circuit is 750 V. Rated operational current AC-23A is 16 A at 380 to 415 V and 500 V, and 10 A at 690 V; AC-22A is 32 A at those voltages. Rated operational power AC-23A is 7.5 kW at 380 to 415 V, 500 V, and 690 V. Conventional thermal current is 40 A fully enclosed. Dimensions are 146 mm wide, 198 mm high, and 110 mm deep, weighing 1.6 kg. Cable cross-section is 0.75 to 10 mm².
- OT16ELMM6A
ABB isolating switch OT16ELMM6A, enclosure of steel sheet, 6-pole, front-operated selector handle in red/yellow. Degree of protection acc. to IEC 60529 IP54; pollution degree 3. Rated insulation voltage acc. to IEC/EN 60664-1 750 V; rated operational voltage main circuit 750 V. Conventional thermal current (Ithe) 40 A fully enclosed. Rated operational current AC-22A: 32 A at 380 to 415 V, 500 V, and 690 V. Rated operational current AC-23A: 16 A at 380 to 415 V and 500 V, 10 A at 690 V. Rated operational power AC-23A: 7.5 kW at 380 to 415 V, 500 V, and 690 V. Cable cross-section 0.75 to 10 mm2, entry up/down. One NO mounted auxiliary contact; maximum 2 NO, 2 NC. Net dimensions 146 x 198 x 110 mm; net weight 1.9 kg.
- OT16ELMM6T
ABB OT16ELMM6T is a six-pole isolating switch supplied in a steel sheet enclosure. It is rated for a conventional thermal current (Ithe) of 40 A fully enclosed, with a rated insulation voltage (Ui) of 750 V according to IEC/EN 60664-1. Power loss is 1.6 W per pole at rated operating conditions. The enclosure provides IP54 protection according to IEC 60529 at pollution degree 3. Cable cross-section range is 0.75 to 10 mm², with cable entry from above or below and two outlets per side: 2xø25.5 + ø16.5. Dimensions are 146 mm wide, 198 mm high, and 110 mm deep; net weight is 1.9 kg. The selector handle is black. One normally open auxiliary contact is mounted; up to 2 NO and 2 NC can be fitted.
- OT16ELPP3A1
ABB isolating switch OT16ELPP3A1, manufacturer ID 1SCA022462R0410. Three-pole (3P) switch in a steel sheet enclosure with selector handle, red/yellow. Rated insulation voltage Ui is 750 V acc. to IEC/EN 60664-1; rated operational voltage main circuit 750 V. Conventional thermal current Ithe is 40 A fully enclosed. Rated operational current AC-22A is 32 A at 380 to 415 V, 500 V, and 690 V; AC-23A is 16 A at 380 to 415 V and 500 V, and 10 A at 690 V. Rated operational power AC-23A is 7.5 kW at 380 to 415 V, 500 V, and 690 V. Cable cross-section 0.75 to 10 mm2, cable entry up/down. Mounted auxiliary contacts 1 NO, 0 NC; maximum 2 NO, 2 NC. Degree of protection IP54 acc. to IEC 60529. Net dimensions 255 mm H x 176 mm W x 160 mm D; net weight 1.6 kg.