- OT16ELPP3A1
ABB isolating switch OT16ELPP3A1, manufacturer ID 1SCA022462R0410. Three-pole (3P) switch in a steel sheet enclosure with selector handle, red/yellow. Rated insulation voltage Ui is 750 V acc. to IEC/EN 60664-1; rated operational voltage main circuit 750 V. Conventional thermal current Ithe is 40 A fully enclosed. Rated operational current AC-22A is 32 A at 380 to 415 V, 500 V, and 690 V; AC-23A is 16 A at 380 to 415 V and 500 V, and 10 A at 690 V. Rated operational power AC-23A is 7.5 kW at 380 to 415 V, 500 V, and 690 V. Cable cross-section 0.75 to 10 mm2, cable entry up/down. Mounted auxiliary contacts 1 NO, 0 NC; maximum 2 NO, 2 NC. Degree of protection IP54 acc. to IEC 60529. Net dimensions 255 mm H x 176 mm W x 160 mm D; net weight 1.6 kg.
- OT16ELPP3A1Z
ABB OT16ELPP3A1Z is a three-pole isolating switch in a steel sheet enclosure with a red/yellow selector handle. It is rated 40 A conventional thermal current (fully enclosed) and 750 V rated insulation voltage according to IEC/EN 60664-1. Rated operational current is 32 A at AC-22A for 380 to 415 V, 500 V, and 690 V, and 16 A at AC-23A for 380 to 415 V and 500 V, 10 A at 690 V. Rated operational power at AC-23A is 7.5 kW at 380 to 415 V, 500 V, and 690 V. The enclosure provides IP65 protection according to IEC 60529. Cable cross-section is 0.75 to 10 mm², with up/down cable entry. Dimensions are 176 mm wide, 255 mm high, and 160 mm deep; net weight is 1.6 kg. One NO auxiliary contact is mounted, with space for up to 2 NO and 2 NC.
- OT16ELPP3AZ
ABB OT16ELPP3AZ is a 3-pole isolating switch in a steel sheet enclosure, identified by manufacturer ID 1SCA022462R1480. It provides IP65 protection according to IEC 60529. Rated insulation voltage is 750 V according to IEC/EN 60664-1. Rated operational current is 32 A at 380 to 415 V, 500 V, and 690 V for AC-22A, and 16 A at 380 to 415 V and 500 V, and 10 A at 690 V for AC-23A. Rated operational power for AC-23A is 7.5 kW at 380 to 415 V, 500 V, and 690 V. Conventional thermal current is 40 A fully enclosed. Cable cross-section is 0.75 to 10 mm². Dimensions are 176 mm width, 255 mm height, and 160 mm depth, with 1.6 kg net weight. Mounted auxiliary contacts are 1 NO, 0 NC; maximum is 2 NO, 2 NC.
- OT16ELPP3B
ABB OT16ELPP3B is a three-pole enclosed isolating switch supplied under manufacturer ID 1SCA022461R8000. The steel sheet enclosure measures 176 mm wide, 255 mm high, and 170 mm deep, with a net weight of 1.6 kg. It provides IP54 protection according to IEC 60529 and accepts cable cross-sections from 0.75 to 10 mm², with cable entry from above or below. Rated insulation voltage is 750 V according to IEC/EN 60664-1. Rated operational current is 16 A at 380 to 415 V and 690 V for AC-22A, and 16 A at 380 to 415 V and 10 A at 690 V for AC-23A. Conventional thermal current is 25 A fully enclosed. The selector handle is black. Up to two NO and two NC auxiliary contacts can be mounted; none are fitted.
- OT16ELPP3T
ABB OT16ELPP3T is a 3-pole isolating switch supplied in a steel sheet enclosure with IP54 protection according to IEC 60529. The enclosure measures 255 mm high, 176 mm wide, and 170 mm deep, and weighs 1.6 kg. It uses a black selector handle and accepts cable entry from above or below, with cable cross-sections from 0.75 to 10 mm². Conventional thermal current (Ithe) is 40 A fully enclosed. Rated insulation voltage (Ui) is 750 V according to IEC/EN 60664-1. Rated operational current is 32 A at AC-22A for 380 to 415 V, 500 V, and 690 V, and 16 A at AC-23A for 380 to 415 V and 500 V, 10 A at 690 V. One normally open auxiliary contact is mounted; up to 2 NO and 2 NC can be fitted.
- OT16ELPP3T1
ABB OT16ELPP3T1 is a 3-pole, front-operated, non-fusible isolating switch supplied in a steel sheet enclosure with IP54 protection according to IEC 60529. The enclosure measures 176 mm wide, 255 mm high, and 170 mm deep, and weighs 1.6 kg. Cable entry is from above or below, with two outlets per side sized 2xø28.3 + ø18.6, accepting cable cross-sections from 0.75 to 10 mm². Rated insulation voltage is 750 V according to IEC/EN 60664-1. Rated operational current AC-23A is 16 A at 380 to 415 V and 500 V, and 10 A at 690 V; AC-22A is 32 A at 380 to 415 V, 500 V, and 690 V. Conventional thermal current is 40 A fully enclosed. One NO auxiliary contact is mounted; up to 2 NO and 2 NC can be fitted. A black selector handle is included.
- OT16ELPP3TZ
The ABB OT16ELPP3TZ is a 3-pole, front-operated, non-fusible isolating switch supplied in a steel sheet enclosure with IP65 protection according to IEC 60529. It has a black selector handle and protected clamp terminals. Rated insulation voltage is 750 V according to IEC/EN 60664-1. Conventional thermal current in the fully enclosed state is 40 A. Rated operational current is 32 A at 380 to 415 V, 500 V, and 690 V for AC-22A, and 16 A at 380 to 415 V and 500 V, 10 A at 690 V for AC-23A. Rated operational power for AC-23A is 7.5 kW at 380 to 415 V, 500 V, and 690 V. Cable cross-section is 0.75 to 10 mm². One NO auxiliary contact is mounted; up to 2 NO and 2 NC can be mounted. Dimensions are 176 mm wide, 255 mm high, and 160 mm deep; net weight is 1.6 kg.
- OT16ELPP4B
ABB OT16ELPP4B is a four-pole isolating switch in a steel sheet enclosure with IP54 protection according to IEC 60529. It measures 176 mm wide, 255 mm high, and 170 mm deep, and weighs 1.6 kg. Cable cross-section range is 0.75 to 10 mm², with up/down cable entry and two outlets per side: 2xø28.3+ø18.6 / 2xø28.3+ø18.6. Conventional thermal current (Ithe) is 25 A fully enclosed. Rated insulation voltage (Ui) is 750 V according to IEC/EN 60664-1. Rated operational current is 16 A at 380 to 415 V and 16 A at 690 V for AC-22A, and 16 A at 380 to 415 V and 10 A at 690 V for AC-23A. Power loss is 0.3 W per pole at rated operating conditions. The selector handle is black. Maximum mounted auxiliary contacts are 2 NO, 2 NC; mounted auxiliary contacts are 0 NO, 0 NC. Manufacturer ID: 1SCA022467R8080.