- VB75
ABB VB75 is an industrial catalog item. Key specifications include ABB Type Designation: -, Core Credit: 0.00, Frame Size: Undefined, and Gross Volume: 0 in³. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- VB7A-30-01-01
The ABB VB7A-30-01-01 is a 3-pole invertible contactor with three normally open main contacts and one normally closed auxiliary contact. It has a 24 V AC control circuit voltage and a rated operational current of 20 A at 380/440 V and 40 °C. Rated operational power in AC-3 is 5.5 kW at 400 V and 500 V three-phase, and 3 kW at 230 V and 690 V three-phase. The main circuit is rated 690 V AC, with a rated impulse withstand voltage of 6 kV and conventional free-air thermal current of 20 A. Mechanical durability is 10,000,000 cycles. Dimensions are 96.2 mm wide, 57.5 mm high, and 46.7 mm deep, weighing 0.355 kg. It mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715.
- VB7A-30-01-02
ABB VB7A-30-01-02 invertible contactor, manufacturer ID GJL1311911R0012. Three-pole device with three NO main contacts and one NC auxiliary contact. Rated operational current AC-1: 20 A at 220/240 V and 380/440 V at 40 °C, 16 A at 55 °C, and 6 A at 690 V at both temperatures. Rated operational power AC-3: 3 kW at 230 V three-phase, 5.5 kW at 400 V and 500 V three-phase, and 3 kW at 690 V three-phase. Coil voltage is 42 V AC, with operating limits of 0.85 to 1.1 x Uc per IEC 60947-4-1 at up to 55 °C. Dimensions are 96.2 mm wide, 57.5 mm high, and 46.7 mm deep; net weight 0.355 kg. Main circuit terminals are IP20. Mechanical durability is 10,000,000 cycles. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, and UL 60947-4-1.
- VB7A-30-01-03
The ABB VB7A-30-01-03 is an invertible contactor with three main NO contacts and one auxiliary NC contact, rated 48 V AC control circuit voltage. Main circuit rated operational voltage is 690 V AC, rated impulse withstand voltage 6 kV, and rated insulation voltage 690 V. Rated operational power AC-3 is 5.5 kW at 400 V and 500 V three-phase, and 3 kW at 230 V and 690 V three-phase. Dimensions are 96.2 mm width, 57.5 mm height, and 46.7 mm depth, with 0.355 kg net weight. Mechanical durability is 10,000,000 cycles. Ambient operating temperature range is -20 to +55 °C. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1, and IEC 60335-2-40 A2L.
- VB7A-30-01-80
ABB VB7A-30-01-80 invertible contactor, manufacturer ID GJL1311911R8010. Three-pole device with three NO main contacts and one NC auxiliary contact. Rated operational voltage: main circuit 690 V AC / 220 V DC; auxiliary circuit 690 V AC / 250 V DC. Rated operational current AC-1: 20 A at 40 °C and 16 A at 55 °C (220/240 V and 380/440 V); 6 A at 690 V. Rated operational power AC-3: 3 kW at 230 V, 5.5 kW at 400 V and 500 V, 3 kW at 690 V. Control circuit voltage 220 to 240 V AC. Dimensions 96.2 x 57.5 x 46.7 mm, 0.355 kg. DIN-rail mounting per IEC 60715. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1.
- VB7A-30-01-84
The ABB VB7A-30-01-84 is a 3-pole invertible contactor with three NO main contacts and one NC auxiliary contact. It measures 96.2 mm wide, 57.5 mm high, and 46.7 mm deep, and weighs 0.355 kg. The control circuit is rated 110 to 127 V AC, with coil operating limits of 0.85 to 1.1 x Uc according to IEC 60947-4-1 for AC supply at temperatures up to 55 °C. Main circuit ratings include 690 V AC, 6 kV impulse withstand, and AC-3 motor power of 3 kW at 230 V, 5.5 kW at 400 V and 500 V, and 3 kW at 690 V. Screw terminals accept rigid conductors from 1 to 4 mm², with a tightening torque of 0.8 to 1.1 N·m. It mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715.
- VB7A-30-01-85
ABB invertible contactor VB7A-30-01-85, manufacturer ID GJL1311911R8015. Three-pole device with three NO main contacts and one NC auxiliary contact. Rated operational voltage: main circuit 690 V AC / 220 V DC; auxiliary circuit 690 V AC / 250 V DC. Rated frequency 50 Hz, 60 Hz, and DC. Rated control circuit voltage 380 to 415 V AC, with coil operating limits 0.85 to 1.1 x Uc according to IEC 60947-4-1 for AC supply at temperatures up to 55 °C. Rated operational power AC-3: 3 kW at 230 V, 5.5 kW at 400 V and 500 V, 3 kW at 690 V, three-phase. Dimensions 96.2 x 57.5 x 46.7 mm; net weight 0.355 kg. Main circuit terminals IP20. DIN rail mounting per IEC 60715. Ambient operating temperature -20 to +55 °C.
- VB7A-30-01-F-01
ABB invertible contactor VB7A-30-01-F-01, manufacturer ID GJL1311913R0011. Three-pole device with three main NO contacts, no main NC contacts, and one auxiliary NC contact. Rated operational voltage is 690 V AC for main and auxiliary circuits, 220 V DC for the main circuit, and 250 V DC for the auxiliary circuit. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V, and 6 A at 40 °C and 55 °C for 690 V. Rated operational power AC-3 is 3 kW at 230 V, 5.5 kW at 400 V and 500 V, and 3 kW at 690 V, three-phase. Control circuit voltage is 24 V AC. Dimensions are 96.2 mm width, 57.5 mm height, and 46.7 mm depth; net weight 0.345 kg.