- VB7A-30-01-84
The ABB VB7A-30-01-84 is a 3-pole invertible contactor with three NO main contacts and one NC auxiliary contact. It measures 96.2 mm wide, 57.5 mm high, and 46.7 mm deep, and weighs 0.355 kg. The control circuit is rated 110 to 127 V AC, with coil operating limits of 0.85 to 1.1 x Uc according to IEC 60947-4-1 for AC supply at temperatures up to 55 °C. Main circuit ratings include 690 V AC, 6 kV impulse withstand, and AC-3 motor power of 3 kW at 230 V, 5.5 kW at 400 V and 500 V, and 3 kW at 690 V. Screw terminals accept rigid conductors from 1 to 4 mm², with a tightening torque of 0.8 to 1.1 N·m. It mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715.
- VB7A-30-01-85
ABB invertible contactor VB7A-30-01-85, manufacturer ID GJL1311911R8015. Three-pole device with three NO main contacts and one NC auxiliary contact. Rated operational voltage: main circuit 690 V AC / 220 V DC; auxiliary circuit 690 V AC / 250 V DC. Rated frequency 50 Hz, 60 Hz, and DC. Rated control circuit voltage 380 to 415 V AC, with coil operating limits 0.85 to 1.1 x Uc according to IEC 60947-4-1 for AC supply at temperatures up to 55 °C. Rated operational power AC-3: 3 kW at 230 V, 5.5 kW at 400 V and 500 V, 3 kW at 690 V, three-phase. Dimensions 96.2 x 57.5 x 46.7 mm; net weight 0.355 kg. Main circuit terminals IP20. DIN rail mounting per IEC 60715. Ambient operating temperature -20 to +55 °C.
- VB7A-30-01-F-01
ABB invertible contactor VB7A-30-01-F-01, manufacturer ID GJL1311913R0011. Three-pole device with three main NO contacts, no main NC contacts, and one auxiliary NC contact. Rated operational voltage is 690 V AC for main and auxiliary circuits, 220 V DC for the main circuit, and 250 V DC for the auxiliary circuit. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V, and 6 A at 40 °C and 55 °C for 690 V. Rated operational power AC-3 is 3 kW at 230 V, 5.5 kW at 400 V and 500 V, and 3 kW at 690 V, three-phase. Control circuit voltage is 24 V AC. Dimensions are 96.2 mm width, 57.5 mm height, and 46.7 mm depth; net weight 0.345 kg.
- VB7A-30-01-F-80
The ABB VB7A-30-01-F-80 is an invertible contactor with three main NO contacts and one auxiliary NC contact. It measures 96.2 mm wide, 57.5 mm high, and 46.7 mm deep, and weighs 0.345 kg. The main circuit is rated 690 V AC, with a rated impulse withstand voltage of 6 kV and a rated insulation voltage of 690 V. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V, and 6 A at 690 V. Rated operational power AC-3 is 5.5 kW at 400 V and 500 V. The coil is rated 220 to 240 V AC. It mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715.
- VB7A-30-01-P-01
The ABB VB7A-30-01-P-01 is an invertible contactor with three main NO contacts and one auxiliary NC contact. It measures 96.2 mm wide, 57.5 mm high, and 47.7 mm deep, and weighs 0.345 kg. The main circuit is rated 690 V AC and 220 V DC, with a rated impulse withstand voltage of 6 kV and rated insulation voltage of 690 V. Rated operational current AC-1 is 12 A at 220/240 V and 380/440 V, and 6 A at 690 V. Rated operational power AC-3 is 3 kW at 230 V, 5.5 kW at 400 V and 500 V, and 3 kW at 690 V. The control circuit is 24 V AC. It mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715.
- VB7A-30-01-P-03
The ABB VB7A-30-01-P-03 is a 3-pole invertible contactor with three NO main contacts and one NC auxiliary contact. It has a rated control circuit voltage of 48 V AC, with coil operating limits of 0.85 to 1.1 x Uc according to IEC 60947-4-1 for AC supply at temperatures up to 55 °C. Rated operational power AC-3 is 3 kW at 230 V three-phase, 5.5 kW at 400 V three-phase, 5.5 kW at 500 V three-phase, and 3 kW at 690 V three-phase. Rated insulation voltage is 690 V, and rated impulse withstand voltage is 6 kV. The contactor measures 96.2 mm wide, 57.5 mm high, and 47.7 mm deep, weighs 0.345 kg, and mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715.
- VB7A-30-01-P-80
The ABB VB7A-30-01-P-80 is a 3-pole invertible contactor with three normally open main contacts and one normally closed auxiliary contact. It measures 96.2 mm wide, 57.5 mm high, and 47.7 mm deep, and weighs 0.345 kg. The control circuit voltage is 220 to 240 V AC, with coil operating limits of 0.85 to 1.1 times Uc at ambient temperatures up to 55 °C. Rated operational power in AC-3 is 3 kW at 230 V three-phase, 5.5 kW at 400 V and 500 V three-phase, and 3 kW at 690 V three-phase. Main circuit terminals are IP20. Mounting is on TH35-15 or TH35-7.5 DIN rail per IEC 60715. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1, and IEC 60335-2-40 A2L.
- VB7A-30-10-01
The ABB VB7A-30-10-01 is a 3-pole invertible contactor with three normally open main contacts and one normally open auxiliary contact. Its coil is rated 24 V AC, with operating limits of 0.85 to 1.1 x Uc according to IEC 60947-4-1 for AC supply at ambient temperatures up to 55 °C. Rated operational power in AC-3 is 3 kW at 230 V three-phase, 5.5 kW at 400 V and 500 V three-phase, and 3 kW at 690 V three-phase. Rated operational current AC-1 is 20 A at 220/240 V and 380/440 V at 40 °C, and 6 A at 690 V. Dimensions are 96.2 mm wide, 57.5 mm high, and 46.7 mm deep; net weight is 0.355 kg. Mechanical durability is 10,000,000 cycles. Main circuit terminals are IP20. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1, and IEC 60335-2-40 A2L.