- VB7A-30-10-02
The ABB VB7A-30-10-02 is an invertible contactor with three main NO contacts, one auxiliary NO contact, and no NC contacts. It measures 96.2 mm wide, 57.5 mm high, and 46.7 mm deep, and weighs 0.355 kg. Rated operational voltage is 690 V AC for main and auxiliary circuits, with main circuit DC ratings of 220 V and auxiliary circuit DC 250 V. Rated operational power AC-3 is 5.5 kW at 400 V and 500 V three-phase, and 3 kW at 230 V and 690 V three-phase. The control circuit voltage is 42 V AC. Mechanical durability is 10,000,000 cycles. Ambient operating temperature is -20 to +55 degrees C. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, and UL 60947-4-1.
- VB7A-30-10-80
ABB invertible contactor VB7A-30-10-80, manufacturer ID GJL1311911R8100. Three-pole device with three main NO contacts and one auxiliary NO contact. Rated operational power AC-3 is 3 kW at 230 V three-phase, 5.5 kW at 400 V three-phase, 5.5 kW at 500 V three-phase, and 3 kW at 690 V three-phase. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V, and 6 A at both 40 °C and 55 °C for 690 V. Control circuit voltage is 220 to 240 V AC. Coil operating limits per IEC 60947-4-1 for AC supply are 0.85 to 1.1 x Uc at up to 55 °C. Dimensions are 96.2 mm width, 57.5 mm height, 46.7 mm depth; net weight 0.355 kg.
- VB7A-30-10-84
ABB invertible contactor VB7A-30-10-84, manufacturer ID GJL1311911R8104. Three-pole device with three normally open main contacts and one normally open auxiliary contact. Rated operational voltage: main circuit 690 V AC and 220 V DC; auxiliary circuit 690 V AC and 250 V DC. Rated frequency: main circuit 50 Hz, 60 Hz, and DC. Rated control circuit voltage 110 to 127 V AC. Rated operational power AC-3: 3 kW at 230 V three-phase, 5.5 kW at 400 V and 500 V three-phase, and 3 kW at 690 V three-phase. Dimensions 96.2 mm width, 57.5 mm height, 46.7 mm depth; net weight 0.355 kg. Screw terminals, DIN rail mounting per IEC 60715. Mechanical durability 10,000,000 cycles. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1, IEC 60335-2-40 A2L.
- VB7A-30-10-85
ABB VB7A-30-10-85 invertible contactor, manufacturer ID GJL1311911R8105. Three-pole contactor with three NO main contacts and one NO auxiliary contact. Rated operational voltage: main circuit 690 V AC / 220 V DC; auxiliary circuit 690 V AC / 250 V DC. Rated control circuit voltage 380 to 415 V AC. Rated operational current AC-1: 20 A at 40 °C and 16 A at 55 °C (220/240 V and 380/440 V); 6 A at 690 V. Rated operational power AC-3: 3 kW at 230 V, 5.5 kW at 400 V and 500 V, 3 kW at 690 V. Rated impulse withstand voltage 6 kV; rated insulation voltage 690 V. Mechanical durability 10,000,000 cycles. Dimensions 96.2 x 57.5 x 46.7 mm; net weight 0.355 kg. Main circuit terminals IP20; pollution degree 3. Ambient operation -20 to +55 °C.
- VB7A-30-10-F-01
The ABB VB7A-30-10-F-01 is a 3-pole invertible contactor with three normally open main contacts and one normally open auxiliary contact. It measures 96.2 mm wide, 57.5 mm high, and 46.7 mm deep, and weighs 0.345 kg. The main circuit is rated 690 V AC and 220 V DC, with a rated impulse withstand voltage of 6 kV and rated insulation voltage of 690 V. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V, and 6 A at 690 V. Rated operational power AC-3 is 3 kW at 230 V, 5.5 kW at 400 V and 500 V, and 3 kW at 690 V. The coil is rated 24 V AC. Mechanical durability is 10,000,000 cycles. DIN-rail mounting is per IEC 60715.
- VB7A-30-10-F-80
ABB invertible contactor VB7A-30-10-F-80, manufacturer ID GJL1311913R8100. Three-pole device with three main NO contacts and one auxiliary NO contact. Rated operational voltage: main circuit 690 V AC / 220 V DC, auxiliary circuit 690 V AC / 250 V DC. Rated control circuit voltage 220 to 240 V AC; coil operating limits per IEC 60947-4-1 for AC supply are 0.85 to 1.1 x Uc at up to 55 °C. Rated operational power AC-3 is 3 kW at 230 V and 5.5 kW at 400 V and 500 V, three-phase. Rated operational current AC-1 is 20 A at 220/240 V and 380/440 V at 40 °C, 16 A at 55 °C, and 6 A at 690 V. Mechanical durability 10,000,000 cycles. Dimensions 96.2 x 57.5 x 46.7 mm; net weight 0.345 kg. Main circuit terminals IP20. DIN-rail mounting per IEC 60715.
- VB7A-30-10-P-01
ABB VB7A-30-10-P-01 invertible contactor, manufacturer ID GJL1311919R0101. Three-pole device with three main NO contacts and one auxiliary NO contact, rated control circuit voltage 24 V AC. Rated operational power AC-3 is 3 kW at 230 V three-phase, 5.5 kW at 400 V three-phase, 5.5 kW at 500 V three-phase, and 3 kW at 690 V three-phase. Rated operational current AC-1 is 12 A at 220/240 V and 380/440 V, and 6 A at 690 V. Rated insulation voltage is 690 V, rated impulse withstand voltage 6 kV. Dimensions are 96.2 mm width, 57.5 mm height, 47.7 mm depth; net weight 0.345 kg. DIN-rail mounting per IEC 60715. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, and UL 60947-4-1.
- VB7A-30-10-P-02
The ABB VB7A-30-10-P-02 is a 3-pole invertible contactor with three NO main contacts and one NO auxiliary contact. It measures 96.2 mm wide, 57.5 mm high, and 47.7 mm deep, and weighs 0.345 kg. Main circuit ratings include 690 V AC and 220 V DC, 6 kV impulse withstand, and 12 A AC-1 at 220/240 V and 380/440 V at 40 °C and 55 °C, or 6 A at 690 V. AC-3 power is 3 kW at 230 V, 5.5 kW at 400 V and 500 V, and 3 kW at 690 V. The coil is 42 V AC with operating limits of 0.85 to 1.1 x Uc at up to 55 °C. Main terminals are IP20.