- NFC53E-88
ABB NFC53E-88 intermediate relay, manufacturer ID 1SBH131001R8853. Auxiliary contact configuration: 5 NO and 3 NC, with no main contacts. Rated operational voltage of the auxiliary circuit is 690 V; rated frequency is 50/60 Hz for auxiliary, control, and main circuits. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated insulation voltage is 690 V per IEC 60947-5-1 and 600 V per UL/CSA; rated impulse withstand voltage is 6 kV. Coil consumption is 2.3 W, with rated control circuit voltage 230 to 240 V at 50 Hz and 240 to 260 V at 60 Hz. Dimensions are 45 mm wide, 110.5 mm deep, 86 mm high; net weight 0.352 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-5-1-14.
- NFC53EK-34
ABB NFC53EK-34 intermediate relay, manufacturer ID 1SBH131005R3453. It has 0 main contacts NO and 0 main contacts NC, with 5 auxiliary contacts NO and 3 auxiliary contacts NC. Dimensions are 45 mm width, 110.5 mm depth/length, and 92.3 mm height; net weight is 0.359 kg. Rated operational voltage is 690 V for both auxiliary and main circuits, at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Standards include IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, and CSA C22.2 No. 60947-5-1-14. Coil consumption is 2.3 W.
- NFC53EK-42
ABB NFC53EK-42 intermediate relay, manufacturer ID 1SBH131005R4253. It has five auxiliary contacts NO and three auxiliary contacts NC, with no main contacts. Rated operational voltage is 690 V for both auxiliary and main circuits, at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-15 is 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 400/440 V, and 2 A at 500 V and 690 V. Rated control circuit voltage is 230 to 240 V at 50 Hz and 277 V at 60 Hz, with coil consumption 2.3 W. Dimensions are 45 mm width, 110.5 mm depth, 92.3 mm height, and 0.359 kg net weight. Standards include IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, and CSA C22.2 No. 60947-5-1-14.
- NFC53EK-80
ABB NFC53EK-80 intermediate relay, manufacturer ID 1SBH131005R8053. Dimensions are 45 mm wide, 110.5 mm deep, and 92.3 mm high, with a net weight of 0.359 kg. Contact arrangement: 0 main contacts NC, 5 auxiliary contacts NO, and 3 auxiliary contacts NC. Rated operational voltage is 690 V for both auxiliary and main circuits, at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated insulation voltage is 690 V per IEC 60947-5-1 and 600 V per UL/CSA; rated impulse withstand voltage is 6 kV. Coil consumption is 2.3 W. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-5-1-14.
- NFC53EK-81
The ABB NFC53EK-81 is an intermediate relay with manufacturer ID 1SBH131005R8153. It measures 45 mm wide, 110.5 mm deep, and 92.3 mm high, and weighs 0.368 kg. Contact configuration is 5 auxiliary contacts NO and 3 auxiliary contacts NC, with 0 main contacts NC. Rated operational voltage is 690 V for both auxiliary and main circuits, at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated control circuit voltage is 24 V at 50 Hz and 24 V at 60 Hz, with coil consumption of 2.3 W. Standards include IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, and CSA C22.2 No. 60947-5-1-14.
- NFC53EK-84
ABB NFC53EK-84 intermediate relay, manufacturer ID 1SBH131005R8453. It has five auxiliary normally open contacts and three auxiliary normally closed contacts, with no main normally closed contacts. Dimensions are 45 mm wide, 110.5 mm deep, and 92.3 mm high; net weight is 0.365 kg. Rated operational voltage is 690 V for auxiliary and main circuits, at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated insulation voltage is 690 V per IEC 60947-5-1 and 600 V per UL/CSA; rated impulse withstand voltage is 6 kV. Coil consumption is 2.3 W. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-5-1-14.
- NFC53EK-85
ABB NFC53EK-85 intermediate relay, manufacturer ID 1SBH131005R8553. It has five normally open and three normally closed auxiliary contacts, with no main contacts. Dimensions are 45 mm wide, 110.5 mm deep, and 92.3 mm high; net weight 0.359 kg. Rated operational voltage is 690 V for both auxiliary and main circuits at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated control circuit voltage is 380 to 400 V at 50 Hz and 400 to 415 V at 60 Hz; coil consumption is 2.3 W. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-5-1-14.
- NFC53EK-86
ABB NFC53EK-86 intermediate relay, manufacturer ID 1SBH131005R8653. It has 5 normally open and 3 normally closed auxiliary contacts, with no main contacts. Dimensions are 45 mm wide, 110.5 mm deep, 92.3 mm high, and 0.359 kg. Rated operational voltage is 690 V for auxiliary and main circuits at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated insulation voltage is 690 V per IEC 60947-4-1 and IEC 60947-5-1, and 600 V per UL/CSA. Rated impulse withstand voltage is 6 kV. Standards include IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, and CSA C22.2 No. 60947-5-1-14.