- NFC53EK-86
ABB NFC53EK-86 intermediate relay, manufacturer ID 1SBH131005R8653. It has 5 normally open and 3 normally closed auxiliary contacts, with no main contacts. Dimensions are 45 mm wide, 110.5 mm deep, 92.3 mm high, and 0.359 kg. Rated operational voltage is 690 V for auxiliary and main circuits at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated insulation voltage is 690 V per IEC 60947-4-1 and IEC 60947-5-1, and 600 V per UL/CSA. Rated impulse withstand voltage is 6 kV. Standards include IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, and CSA C22.2 No. 60947-5-1-14.
- NFC53EK-88
ABB NFC53EK-88 intermediate relay, manufacturer ID 1SBH131005R8853. Dimensions are 45 mm wide, 110.5 mm deep, 92.3 mm high, and 0.36 kg. Contact arrangement: 0 main contacts NC, 5 auxiliary contacts NO, and 3 auxiliary contacts NC. Rated operational voltage is 690 V for both auxiliary and main circuits, at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated insulation voltage is 690 V per IEC 60947-5-1 and 600 V per UL/CSA; rated impulse withstand voltage is 6 kV. Coil consumption is 2.3 W. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-5-1-14.
- NFC62E-34
ABB NFC62E-34 intermediate relay, manufacturer ID 1SBH131001R3462. Auxiliary contact configuration: 6 NO and 2 NC, with no main contacts. Rated operational voltage for the auxiliary circuit is 690 V at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-15: 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 400/440 V, and 2 A at 500 V and 690 V. Rated insulation voltage is 690 V per IEC 60947-4-1 and VDE 0110 (Gr. C), and 600 V per UL/CSA. Coil consumption is 2.3 W. Dimensions are 45 mm wide, 110.5 mm deep, and 86 mm high; net weight 0.351 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-5-1-14.
- NFC62E-42
ABB NFC62E-42 intermediate relay, manufacturer ID 1SBH131001R4262. It has six auxiliary contacts NO and two auxiliary contacts NC, with no main contacts. Auxiliary circuit rated operational voltage is 690 V at 50/60 Hz; rated control circuit voltage is 230 to 240 V at 50 Hz and 277 V at 60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-15 is 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 400/440 V, and 2 A at 500 V and 690 V. Dimensions are 45 mm wide, 110.5 mm deep, 86 mm high; net weight 0.351 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-5-1-14.
- NFC62E-51
ABB NFC62E-51 intermediate relay, manufacturer ID 1SBH131001R5162. It has six auxiliary contacts NO and two auxiliary contacts NC, with no main contacts. Auxiliary circuit rated operational voltage is 690 V at 50/60 Hz; rated control circuit voltage is 400 to 415 V at 50 Hz and 480 V at 60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-15 is 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 400/440 V, and 2 A at 500 V and 690 V. Dimensions are 45 mm width, 110.5 mm depth, 86 mm height; net weight 0.351 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-5-1-14.
- NFC62E-80
ABB NFC62E-80 intermediate relay, manufacturer ID 1SBH131001R8062. Auxiliary contact configuration: 6 NO, 2 NC, no main NC contacts. Rated operational voltage of the auxiliary circuit is 690 V; rated frequency is 50/60 Hz for auxiliary, control, and main circuits. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated insulation voltage is 690 V per IEC 60947-5-1 and 600 V per UL/CSA; rated impulse withstand voltage is 6 kV. Coil consumption is 2.3 W. Dimensions are 45 mm wide, 110.5 mm deep, 86 mm high; net weight 0.351 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-5-1-14.
- NFC62E-81
ABB NFC62E-81 intermediate relay, manufacturer ID 1SBH131001R8162, with 6 normally open and 2 normally closed auxiliary contacts and no main NC contacts. Coil rating is 24 V at 50 Hz and 24 V at 60 Hz, with 2.3 W coil consumption. Auxiliary circuit rated operational voltage is 690 V; rated insulation voltage is 690 V per IEC 60947-5-1 and 600 V per UL/CSA. Conventional free-air thermal current is 16 A per IEC 60947-5-1 at 40 °C. Dimensions are 45 mm wide, 110.5 mm deep, 86 mm high; net weight 0.36 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-5-1-14.
- NFC62E-84
ABB NFC62E-84 intermediate relay, manufacturer ID 1SBH131001R8462. Auxiliary contact configuration: 6 NO and 2 NC, with no main contacts NC. Rated operational voltage of the auxiliary circuit is 690 V; rated frequency is 50/60 Hz for auxiliary, control, and main circuits. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated insulation voltage is 690 V per IEC 60947-5-1 and 600 V per UL/CSA; rated impulse withstand voltage is 6 kV. Coil consumption is 2.3 W. Dimensions are 45 mm wide, 110.5 mm deep, 86 mm high; net weight 0.357 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-5-1-14.