- NFC62E-80
ABB NFC62E-80 intermediate relay, manufacturer ID 1SBH131001R8062. Auxiliary contact configuration: 6 NO, 2 NC, no main NC contacts. Rated operational voltage of the auxiliary circuit is 690 V; rated frequency is 50/60 Hz for auxiliary, control, and main circuits. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated insulation voltage is 690 V per IEC 60947-5-1 and 600 V per UL/CSA; rated impulse withstand voltage is 6 kV. Coil consumption is 2.3 W. Dimensions are 45 mm wide, 110.5 mm deep, 86 mm high; net weight 0.351 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-5-1-14.
- NFC62E-81
ABB NFC62E-81 intermediate relay, manufacturer ID 1SBH131001R8162, with 6 normally open and 2 normally closed auxiliary contacts and no main NC contacts. Coil rating is 24 V at 50 Hz and 24 V at 60 Hz, with 2.3 W coil consumption. Auxiliary circuit rated operational voltage is 690 V; rated insulation voltage is 690 V per IEC 60947-5-1 and 600 V per UL/CSA. Conventional free-air thermal current is 16 A per IEC 60947-5-1 at 40 °C. Dimensions are 45 mm wide, 110.5 mm deep, 86 mm high; net weight 0.36 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-5-1-14.
- NFC62E-84
ABB NFC62E-84 intermediate relay, manufacturer ID 1SBH131001R8462. Auxiliary contact configuration: 6 NO and 2 NC, with no main contacts NC. Rated operational voltage of the auxiliary circuit is 690 V; rated frequency is 50/60 Hz for auxiliary, control, and main circuits. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated insulation voltage is 690 V per IEC 60947-5-1 and 600 V per UL/CSA; rated impulse withstand voltage is 6 kV. Coil consumption is 2.3 W. Dimensions are 45 mm wide, 110.5 mm deep, 86 mm high; net weight 0.357 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-5-1-14.
- NFC62E-85
ABB NFC62E-85 intermediate relay, manufacturer ID 1SBH131001R8562. It has six auxiliary contacts NO and two auxiliary contacts NC, with no main contacts. Dimensions are 45 mm wide, 110.5 mm deep, and 86 mm high; net weight 0.351 kg. The auxiliary circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-15 is 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 400/440 V, and 2 A at 500 V and 690 V. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-5-1-14.
- NFC62E-86
The ABB NFC62E-86 is an intermediate relay with six normally open and two normally closed auxiliary contacts, and no main contacts. It measures 45 mm wide, 110.5 mm deep, and 86 mm high, and weighs 0.351 kg. Rated operational voltage is 690 V for both auxiliary and main circuits at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated insulation voltage is 690 V according to IEC 60947-4-1 and VDE 0110 (Gr. C), and 600 V according to UL/CSA. Rated impulse withstand voltage is 6 kV. Applicable standards include IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, and CSA C22.2 No. 60947-5-1-14.
- NFC62E-88
ABB NFC62E-88 intermediate relay, manufacturer ID 1SBH131001R8862. Auxiliary contact configuration: 6 NO and 2 NC, with 0 main NC contacts. Rated operational voltage of the auxiliary circuit is 690 V; rated frequency is 50/60 Hz for auxiliary, control, and main circuits. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated insulation voltage is 690 V per IEC 60947-5-1 and 600 V per UL/CSA; rated impulse withstand voltage is 6 kV. Coil consumption is 2.3 W, with rated control circuit voltage 230 to 240 V at 50 Hz and 240 to 260 V at 60 Hz. Dimensions are 45 mm wide, 110.5 mm deep, and 86 mm high; net weight 0.352 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-5-1-14.
- NFC62EK-34
ABB NFC62EK-34 intermediate relay, manufacturer ID 1SBH131005R3462. It has no main contacts and provides 6 normally open plus 2 normally closed auxiliary contacts. Dimensions are 45 mm wide, 110.5 mm deep, and 92.3 mm high, with a net weight of 0.359 kg. Rated operational voltage is 690 V for both auxiliary and main circuits, at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Coil consumption is 2.3 W. Standards listed are IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, and CSA C22.2 No. 60947-5-1-14.
- NFC62EK-42
ABB NFC62EK-42 intermediate relay, manufacturer ID 1SBH131005R4262. It has 6 auxiliary contacts NO and 2 auxiliary contacts NC, with no main contacts. Dimensions are 45 mm wide, 110.5 mm deep, and 92.3 mm high; net weight 0.359 kg. Rated operational voltage is 690 V for auxiliary and main circuits, at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated control circuit voltage is 230 to 240 V at 50 Hz and 277 V at 60 Hz, with coil consumption 2.3 W. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-5-1-14.