- AFC16-30-01-88
ABB AFC16-30-01-88 is a 3-pole AC contactor with three normally open main contacts and one normally closed auxiliary contact. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.303 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Conventional free-air thermal current is 35 A per IEC 60947-4-1 at 40 °C, and 16 A per IEC 60947-5-1 at 40 °C. AC-1 rated operational current is 30 A at 690 V at 40 °C and 60 °C, and 26 A at 70 °C. AC-3 rated operational power is 7.5 kW at 380/400 V and 9 kW at 415 V, 440 V, 500 V, and 690 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFC16-30-01K-34
The ABB AFC16-30-01K-34 is an AC contactor with three normally open main contacts and one normally closed auxiliary contact. It measures 45 mm wide, 77 mm deep, and 92.3 mm high, and weighs 0.306 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50 or 60 Hz. Conventional free-air thermal current is 35 A per IEC 60947-4-1 at 40 °C, and 16 A per IEC 60947-5-1 at 40 °C. Rated operational current AC-3 is 18 A at 415 V and 440 V, 15 A at 500 V, and 10.5 A at 690 V, all at 60 °C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFC16-30-01K-42
The ABB AFC16-30-01K-42 is an AC contactor with three normally open main contacts, no normally open auxiliary contacts, and one normally closed auxiliary contact. It measures 45 mm wide, 77 mm deep, and 92.3 mm high, weighing 0.306 kg. Rated operational voltage is 690 V for both main and auxiliary circuits at 50/60 Hz. Rated operational power AC-3 is 7.5 kW at 380/400 V and 9 kW at 415, 440, 500, and 690 V. Coil control voltage is 230 to 240 V at 50 Hz and 277 V at 60 Hz. It uses push-in spring terminals, mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715, and is rated IP20. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFC16-30-01K-51
The ABB AFC16-30-01K-51 is an AC contactor with three normally open main contacts and one normally closed auxiliary contact. It measures 45 mm wide, 77 mm deep, and 92.3 mm high, and weighs 0.306 kg. The main and auxiliary circuits are rated 690 V at 50/60 Hz. Conventional free-air thermal current is 35 A per IEC 60947-4-1 at 40 °C, and 16 A per IEC 60947-5-1 at 40 °C. Rated operational current AC-1 is 30 A at 690 V at 40 °C and 60 °C, and 26 A at 70 °C. AC-3 ratings include 18 A at 415 V and 440 V at 60 °C, and 10.5 A at 690 V at 60 °C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFC16-30-01K-80
The ABB AFC16-30-01K-80 is a 3-pole AC contactor with one built-in normally closed auxiliary contact and push-in terminals. It measures 45 mm wide, 77 mm deep, and 92.3 mm high, and weighs 0.306 kg. Main and auxiliary circuits are rated 690 V at 50/60 Hz. Conventional free-air thermal current is 35 A per IEC 60947-4-1 at 40 °C, and 16 A per IEC 60947-5-1 at 40 °C. Rated operational current AC-3 is 18 A at 415 V and 440 V, 15 A at 500 V, and 10.5 A at 690 V, all at 60 °C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFC16-30-01K-81
The ABB AFC16-30-01K-81 is a 3-pole AC contactor with three normally open main contacts and one normally closed auxiliary contact. It measures 45 mm wide, 77 mm deep, and 92.3 mm high, and weighs 0.317 kg. Main and auxiliary circuits are rated 690 V, 50/60 Hz. Rated operational current AC-3 is 18 A at 415 V and 440 V, 15 A at 500 V, and 10.5 A at 690 V, all at 60 °C. Rated operational power AC-3 is 7.5 kW at 380/400 V and 9 kW at 415 V, 440 V, 500 V, and 690 V. Coil voltage is 24 V at 50 Hz and 60 Hz. It uses push-in spring terminals and mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715.
- AFC16-30-01K-84
ABB AFC16-30-01K-84 is a 3-pole AC contactor with three normally open main contacts and one normally closed auxiliary contact. It measures 45 mm wide, 77 mm deep, and 92.3 mm high, and weighs 0.314 kg. Main and auxiliary circuits are rated 690 V at 50/60 Hz. Per IEC 60947-4-1, AC-1 rating is 30 A at 40 °C and 60 °C, and 26 A at 70 °C, all at 690 V. AC-3 rating is 18 A at 220/230/240 V, 380/400 V, 415 V, and 440 V, 15 A at 500 V, and 10.5 A at 690 V, at 60 °C. AC-3 power ratings include 4 kW at 220/230/240 V, 7.5 kW at 380/400 V, and 9 kW at 415 V, 440 V, 500 V, and 690 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFC16-30-01K-85
ABB AFC16-30-01K-85 is an AC contactor with three normally open main contacts and one normally closed auxiliary contact. It measures 45 mm wide, 77 mm deep, and 92.3 mm high, and weighs 0.306 kg. The main and auxiliary circuits are rated 690 V at 50/60 Hz. Conventional free-air thermal current is 35 A per IEC 60947-4-1 at 40 °C, and 16 A per IEC 60947-5-1 at 40 °C. Rated operational current AC-3 is 18 A at 415 V and 60 °C, 15 A at 500 V, and 10.5 A at 690 V. Rated operational power AC-3 is 9 kW at 415 V, 7.5 kW at 380/400 V, and 4 kW at 220/230/240 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1. Manufacturer ID 1SBL171005R8501.