- AFC16-30-01K-86
ABB AFC16-30-01K-86 is a 3-pole AC contactor, manufacturer ID 1SBL171005R8601, with three normally open main contacts and one normally closed auxiliary contact. It measures 45 mm wide, 77 mm deep, and 92.3 mm high, weighing 0.306 kg. Rated operational voltage is 690 V for both main and auxiliary circuits at 50/60 Hz. AC-3 ratings include 18 A at 415 V and 10.5 A at 690 V, both at 60 °C, with rated operational power of 9 kW at 415 V and 7.5 kW at 380/400 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AFC16-30-01K-88
The ABB AFC16-30-01K-88 is a 3-pole AC contactor with three normally open main contacts and one normally closed auxiliary contact. It measures 45 mm wide, 77 mm deep, and 92.3 mm high, and weighs 0.311 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Conventional free-air thermal current is 35 A per IEC 60947-4-1 at 40 °C, and 16 A per IEC 60947-5-1 at 40 °C. Rated operational current AC-3 is 18 A at 415 V and 440 V, 15 A at 500 V, and 10.5 A at 690 V, all at 60 °C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFC16-30-10-34
ABB AFC16-30-10-34 AC contactor, manufacturer ID 1SBL171001R3410. It has three normally open main contacts, no normally closed main contacts, and one normally open auxiliary contact. Dimensions are 45 mm wide, 77 mm deep, and 86 mm high, with a net weight of 0.298 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Conventional free-air thermal current is 35 A per IEC 60947-4-1 at 40 °C, and 16 A per IEC 60947-5-1 at 40 °C. AC-3 ratings include 18 A at 415 V and 60 °C, and 10.5 A at 690 V and 60 °C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFC16-30-10-42
ABB AFC16-30-10-42 AC contactor, manufacturer ID 1SBL171001R4210. It has three normally open main contacts and one normally open auxiliary contact, with no normally closed contacts. Dimensions are 45 mm wide, 77 mm deep, and 86 mm high; net weight is 0.298 kg. Main and auxiliary circuits are rated 690 V at 50/60 Hz. Conventional free-air thermal current is 35 A per IEC 60947-4-1 at 40 °C, and 16 A per IEC 60947-5-1 at 40 °C. Rated operational current AC-3 is 18 A at 415 V and 440 V, 15 A at 500 V, and 10.5 A at 690 V, all at 60 °C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFC16-30-10-51
The ABB AFC16-30-10-51 is an AC contactor with three normally open main contacts and one normally open auxiliary contact. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.298 kg. The main and auxiliary circuits are rated 690 V at 50/60 Hz. Per IEC 60947-4-1, conventional free-air thermal current is 35 A at 40 °C; AC-1 rated operational current is 30 A at 690 V and 40 °C. AC-3 ratings include 18 A at 415 V and 60 °C, and 10.5 A at 690 V and 60 °C, with corresponding rated operational power of 9 kW at 415 V and 9 kW at 690 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFC16-30-10-80
ABB AFC16-30-10-80 is a 3-pole AC contactor with three normally open main contacts and one normally open built-in auxiliary contact. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.298 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, with rated frequency 50/60 Hz. Conventional free-air thermal current is 35 A per IEC 60947-4-1 at 40 °C, and 16 A per IEC 60947-5-1 at 40 °C. Rated operational current AC-3 is 18 A at 415 V and 10.5 A at 690 V, both at 60 °C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1. Screw terminals.
- AFC16-30-10-81
ABB AFC16-30-10-81 is a 3-pole AC contactor with three normally open main contacts and one normally open auxiliary contact. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.309 kg. The contactor is rated for a main and auxiliary circuit operational voltage of 690 V at 50/60 Hz. Conventional free-air thermal current is 35 A per IEC 60947-4-1 at 40 °C and 16 A per IEC 60947-5-1 at 40 °C. AC-3 rated operational current is 18 A at 415 V and 440 V, 15 A at 500 V, and 10.5 A at 690 V, all at 60 °C. Applicable standards are IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AFC16-30-10-84
ABB AFC16-30-10-84 is a 3-pole AC contactor with 3 NO main contacts and 1 NO auxiliary contact. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.306 kg. The contactor is rated 690 V for both main and auxiliary circuits at 50/60 Hz. Conventional free-air thermal current is 35 A per IEC 60947-4-1 at 40 °C, and 16 A per IEC 60947-5-1 at 40 °C. Rated operational current AC-1 is 30 A at 690 V and 40 °C or 60 °C, and 26 A at 70 °C. AC-3 ratings include 18 A at 415 V and 60 °C, and 10.5 A at 690 V and 60 °C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.