- AFC16-30-10-81
ABB AFC16-30-10-81 is a 3-pole AC contactor with three normally open main contacts and one normally open auxiliary contact. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.309 kg. The contactor is rated for a main and auxiliary circuit operational voltage of 690 V at 50/60 Hz. Conventional free-air thermal current is 35 A per IEC 60947-4-1 at 40 °C and 16 A per IEC 60947-5-1 at 40 °C. AC-3 rated operational current is 18 A at 415 V and 440 V, 15 A at 500 V, and 10.5 A at 690 V, all at 60 °C. Applicable standards are IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AFC16-30-10-84
ABB AFC16-30-10-84 is a 3-pole AC contactor with 3 NO main contacts and 1 NO auxiliary contact. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.306 kg. The contactor is rated 690 V for both main and auxiliary circuits at 50/60 Hz. Conventional free-air thermal current is 35 A per IEC 60947-4-1 at 40 °C, and 16 A per IEC 60947-5-1 at 40 °C. Rated operational current AC-1 is 30 A at 690 V and 40 °C or 60 °C, and 26 A at 70 °C. AC-3 ratings include 18 A at 415 V and 60 °C, and 10.5 A at 690 V and 60 °C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFC16-30-10-86
The ABB AFC16-30-10-86 is a 3-pole AC contactor with three normally open main contacts and one normally open auxiliary contact. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.298 kg. Rated operational voltage is 690 V for both main and auxiliary circuits at 50/60 Hz. Rated operational current AC-3 is 18 A at 415 V and 440 V, 15 A at 500 V, and 10.5 A at 690 V, all at 60 °C. Rated operational power AC-3 is 7.5 kW at 380/400 V and 9 kW at 415 V, 440 V, 500 V, and 690 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFC16-30-10-88
ABB AFC16-30-10-88 is an AC contactor with three normally open main contacts and one normally open auxiliary contact. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.303 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Conventional free-air thermal current is 35 A per IEC 60947-4-1 at 40 °C, and 16 A per IEC 60947-5-1 at 40 °C. Rated operational current AC-3 is 18 A at 415 V and 60 °C, and 10.5 A at 690 V and 60 °C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFC16-30-10K-34
ABB AFC16-30-10K-34 is an AC contactor with three normally open main contacts and one normally open auxiliary contact. It measures 45 mm wide, 77 mm deep, and 92.3 mm high, and weighs 0.306 kg. Main and auxiliary circuits are rated 690 V at 50/60 Hz. Per IEC 60947-4-1, AC-3 ratings at 60 °C include 18 A at 415 V, 18 A at 440 V, 15 A at 500 V, and 10.5 A at 690 V, with corresponding AC-3 power ratings of 9 kW at 415, 440, 500, and 690 V, 7.5 kW at 380/400 V, and 4 kW at 220/230/240 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1. Manufacturer ID 1SBL171005R3410.
- AFC16-30-10K-42
The ABB AFC16-30-10K-42 is a 3-pole AC contactor with three normally open main contacts and one normally open auxiliary contact. It measures 45 mm wide, 77 mm deep, and 92.3 mm high, and weighs 0.306 kg. Main and auxiliary circuits are rated 690 V at 50/60 Hz. Per IEC 60947-4-1, AC-1 rated operational current is 30 A at 690 V and 40 °C or 60 °C, and 26 A at 70 °C. AC-3 ratings include 18 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, 15 A at 500 V, and 10.5 A at 690 V, all at 60 °C. AC-3 rated operational power is 9 kW at 415 V, 440 V, 500 V, and 690 V, 7.5 kW at 380/400 V, and 4 kW at 220/230/240 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFC16-30-10K-51
ABB AFC16-30-10K-51 is an AC contactor with three normally open main contacts and one normally open auxiliary contact. It measures 45 mm wide, 77 mm deep, and 92.3 mm high, and weighs 0.306 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 18 A at 415 V and 440 V, 15 A at 500 V, and 10.5 A at 690 V, all at 60 °C. Rated operational power AC-3 is 9 kW at 415 V, 440 V, 500 V, and 690 V, 7.5 kW at 380/400 V, and 4 kW at 220/230/240 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFC16-30-10K-80
The ABB AFC16-30-10K-80 is a 3-pole AC contactor with three normally open main contacts and one built-in normally open auxiliary contact. It uses push-in spring terminals. Rated operational voltage is 690 V for the main and auxiliary circuits, with a rated frequency of 50/60 Hz. Rated operational current AC-3 is 18 A at 415 V and 440 V, 15 A at 500 V, and 10.5 A at 690 V, all at 60 °C. Rated operational power AC-3 is 9 kW at 415 V, 440 V, 500 V, and 690 V. The contactor measures 45 mm wide, 77 mm deep, and 92.3 mm high, and weighs 0.306 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.